Cable Specification
4
1
Cable Specification
The cabling system is based on Unshielded Twisted Pair
Category 5e
(Cat5e) or
Category 6
(Cat6).
The cable must be
annealed pure copper
, meeting or exceeding the requirements defined in the
standard ANSI/TIA 568 C.2.
Failure to comply with this cable specification may result in erratic operation of equipment.
The specification below shows the minimum cable requirements, allow for extra cabling if
redundancy is required.
Connection
Cable
A
Door controller with PSU to
each call panel:
2x Cat5e or Cat6.
B
Lock Relay to locks:
2x 1.5mm² multi-stranded flex or singles (route through
any exit/fire switch or break glass for fail safe operation).
C
Lock Relay to exit switch:
1 Pair UTP (2 cores), Cat5e or Cat6.
D
Lock Relay to fire switch:
1 Pair UTP (2 cores), Cat5e or Cat6.
Typical Configuration
FIGURE 1-1
NOTE
Refer to the PRO-DC (Door Controller) Installation Guide for Lock and Exit Switch connections.
Door
PRO-DPC
Call Panel
Lock
PRO-DC-ENC
Door Controller
Cat5e/Cat6 or Fibre
Network
5A Fused
Spur
Mains
Twin Earth
or Flex
2x 1.5mm2 Singles or Flex
Cat5e/Cat6
Exit Switches
2x 1.5mm2 Singles or Flex
2x Cat5e/Cat6