background image

28

IP1639EN - 2015-05-13

3. Technical specifications

Ditec OBBI3BH

Ditec OBBI3BFCH

Power supply

24 V=

24 V=

Absorption

3 A

3 A

Thrust

1500 N

1500 N

Max run

350 mm

350 mm

Opening time

25 s / 90°

25 s / 90°

Service class

3 - FREQUENT

3 - FREQUENT

Intermittence

S2 = 30 min

S3 = 50%

S2 = 30 min

S3 = 50%

Temperature

min -20° C 
max +55° C

min -20° C 
max +55° C

Degree of protection

IP54

IP54

Control panel

E2HOB

E2HOB

Limit switch

-

Magnetic

Applications

m  = leaf width
kg = leaf weight

Limit dimensions

Recommended
dimensions

500 kg

400 kg

300 kg

200 kg

100 kg

m

1

2

3

4

5

3.1 Operating instructions

Service life: 3 (minimum 10÷5 years of working life with 30÷60 cycles a day)
Applications: FREQUENT (For vehicle or pedestrian accesses to town houses or small condo-
miniums with frequent use).
-  Performance characteristics are to be understood as referring to the recommended weight 

(approx. 2/3 of maximum permissible weight). When used with the maximum permissible weight 
a reduction in the above mentioned performance can be expected.

-   Service class, running times, and the number of consecutive cycles are to be taken as merely 

indicative Having been statistically determined under average operating conditions, and are 
therefore not necessarily applicable to specifi c conditions of use.

-   Each automatic entrance has variable elements such as: friction, balancing and environmental 

factors, all of which may substantially alter the performance characteristics of the automatic 
entrance or curtail its working life or parts thereof (including the automatic devices themselves). 
The installer should adopt suitable safety conditions for each particular installation.

Содержание OBBI3BFCH

Страница 1: ...Ditec OBBI Swing gates automation Original instruction www ditecentrematic com IP1639EN Technical manual...

Страница 2: ...24 IP1639EN 2015 05 13...

Страница 3: ...dard installation 29 5 Geared motor references 30 6 Installation 31 6 1 Preliminary checks 31 6 2 Geared motor installation 31 7 Electrical connections 35 7 1 OBBI3BFCH limit switch adjustment 36 8 Or...

Страница 4: ...e motorised or for any deformation during use The safety devices photocells safety edges emergency stops etc must be installed taking into account applicable laws and directives Good Working Methods i...

Страница 5: ...be provided to national competent authorities following a suitably justi ed request Landskrona 06 05 2013 Marco Pietro Zini President Pursuant to Machinery Directive 2006 42 EC the installer who moto...

Страница 6: ...ses or small condo miniums with frequent use Performance characteristics are to be understood as referring to the recommended weight approx 2 3 of maximum permissible weight When used with the maximum...

Страница 7: ...OBBI3BH OBBI3BFCH Left geared motor Left geared motor with limit switch 7 XEL2 LAB4 Photocells Photocells IP55 8 E2HOB Control panel A Connect the power supply to a type approved omnipolar switch with...

Страница 8: ...eferences Ref Code Description 9 Key release 10 Casing 11 Draft tube 12 Tube cover 13 Closing plug 14 Tail bracket 15 Head bracket 16 Cable guide sheat hooking bracket 200 110 995 350 13 12 10 11 9 16...

Страница 9: ...site spaces and overall dimensions NOTE The measurements A and B must be the same in order to have a regular moviment Increasing A decreases the coming up speed during opening Increasing B decreases...

Страница 10: ...lue brown 180 blue brown 1 2 3 4 5 Loosen the motor fastening screws With the reduction gear rotated insert the motor and cap and insert the cable WARNING the motor must be assembled so that the cable...

Страница 11: ...WARNING the stops must keep a 10 mm margin of tube stroke in both the door wing closed and door wing open positions With the gate completely closed position the front bracket 15 check it is aligned w...

Страница 12: ...x it with the screws H supplied Pay attention to the insertion direction The slits on the closing cap 13 must be on the lower part in order to help the water to come out Assemble the casing 10 xing it...

Страница 13: ...be connected to the E2HOB control panel The electrical wiring and the start up of the gearmotors OBBI3BH and OBBI3BFCH are shown in gure and in the installation manuals of the E2H control panel Moto...

Страница 14: ...itches Adjust the limit switches in order to obtain the correct opening and closing of the automation as indicated in gure dima regolazione necorsa limit switch adjusting template necorsa di apertura...

Страница 15: ...are properly tightened Check the electrical wiring is in good condition Reconnect the 230 V power supply and batteries if present Check the power adjustments Check the good operation of all command an...

Страница 16: ...38 IP1639EN 2015 05 13...

Страница 17: ...since this may be dangerous Do not allow children to play or stay within the operating range of the motorised door Keep remote controls and or any other control devices out of the reach of children i...

Страница 18: ...oor wings again turn the key clockwise in the opposite direc tion to the arrow on the gearmotor To facilitate the operation move the door wing slightly WARNING the door wing block and release operatio...

Страница 19: ...cation have been drawn up with the greatest care Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publication We reserve the right to ma...

Страница 20: ...IP1639EN 2015 05 13 Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www ditecentrematic com...

Отзывы: