Regular safety checks

To help you fulfil the national/international requirements and to avoid malfunction and risk for in-
juries, we have provided the following checklist.

Do not use the operator if repair or adjustment is necessary.

Disconnect supply

when cleaning or other maintenance is to be carried out.

If problem

occurs

Daily Action

Activate your operator and check visually, fastening and any damage of

operator

arm system

cables

hinges

door and glass

Also inspect your operator and check visually for

sharp edges on the door leaf and door frame (if any)

condition of door seals

finger protection

and finally that the complete door runs properly and closes slowly in a smooth way

Set the mode selector to OFF and check that the operator and electromechanical lock (if fitted) work

together. Also check that the lock

really secures the door.

Activate the manual activation units

, if any, and walk towards the door. Check that the door has

opened appropriately while you pass the entrance/exit.

Then proceed with the automatic activation units

in the same way.

Check the safety sensors

if any, by standing in the swing path and activate the operator.

The door must not hit you when opening nor when closing.
If you are unsure of which type of sensor you have, please contact your Entrematic Group represent-
ative.

Set the programme selector in AUTO mode. Push the door manually
in escape direction and make sure that no object or function will pre-
vent the door from opening. Also make sure the escape route is free
for use.

By law, these
tests must
be per-
formed regu-

Escape
doors

larly by

Let the door close after an impulse ensuring nothing prevents the door
from closing and locking (if regulations require it).

Fire
doors

trained per-
sonnel.

Take appropriate measures.

=

Contact your Entrematic Group representative. For contact information, see last page.

=

7

Issue 2019-06-11

1004131-EMen-12.0

Содержание EM EMSW

Страница 1: ...Swing Door Operator EM EMSW User Manual Original instructions...

Страница 2: ...10 Safety accessories 10 Troubleshooting 11 Service Maintenance 11 Other products from Entrematic Group 12 Declaration of conformity All rights in and to this material are the sole property of Entrem...

Страница 3: ...rs of age if they have been instructed by a person in charge of their safety The operator can be used by children 8 years of age or younger if they are supervised by a person respons ible for their sa...

Страница 4: ...er is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the receiver with respect to the equipment Move the receiver away...

Страница 5: ...led indoors where it is suitable for almost all types of external and internal swing doors This widely used operator can be found on applications ranging from handicapped access in private homes to hi...

Страница 6: ...PEN TIME HOT When the HOT has elapsed the door will close The EM EMSW can be set in three different modes if a programme selector is installed see picture below In fully manual use or in case of a pow...

Страница 7: ...the door Activate the manual activation units if any and walk towards the door Check that the door has opened appropriately while you pass the entrance exit Then proceed with the automatic activation...

Страница 8: ...be documented To avoid damages to the profiles the brushes weather stripping must be vacuum cleaned weekly Do not expose windows doors or profiles to alkalis Both aluminium and glass are sensitive to...

Страница 9: ...d to all glass sections that are moving Supervision of child applied to both sides of the door Mandatory according to national regulations Recommended if the risk analysis shows use by children Operat...

Страница 10: ...ection see page 8 Troubleshooting Remedies What s wrong The door does not open Change the setting of the mode selector See page 6 The motor does not start Check that there are no objects in the detect...

Страница 11: ...onment Cycles hour in operation Part number Part 100 100 10 High traffic Medium traffic Low traffic 6 6 12 24 331003882 Vibration absorbers and oil plug 6 6 12 24 330000485BK SI PUSH PUSH 335 service...

Страница 12: ...applied BVL BBR UL 325 FCC 47 CFR Part 15 B IEC 60335 2 103 2002 ed 1 2011 ed 2 1 IEC 60335 1 2010 ed 5 EN 1634 1 2008 DIN 18650 1 2 2010 IEC 60950 1 2005 ed 2 ECtypeexaminationorcertificateissuedbya...

Страница 13: ......

Страница 14: ...Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden Tel 46 10 47 48 300 www entrematic com info em entrematic com...

Отзывы: