General safety precautions

This installation manual is intended for professionally competent 

personnel only. Read the instructions carefully before beginning 

to install the product. Incorrect installation may be a source of danger. 

Packaging materials (plastic, polystyrene, etc.) must not be allowed to 

litter the environment and must be kept out of the reach of children for 

whom they may be a source of danger. Before beginning the installation 

check that the product is in perfect condition. 

For repairs or replacements of product only original spare parts must 

be used. These instruction must be kept and forwarded to all possible 

future user of the system.

EC declaration of conformity

The manufacturer Entrematic Group AB, with headquarters in Lodjursga-

tan 10, SE-261 44 Landskrona, Sweden, declares that the safety device 

GOPAVR, GOPAVRS, GOPAVT, SOFA15, SOFA20, SOFA25, SOFB15, SOFB20, 

SOFB25 is compliant to the following european directives and regulations:

EN12978, EN12453, EN12445;

Directive 1999/5/EC R&TTE;

EMC directive 2004/108/EC.

Landskrona, 2015-05-05 

          Marco Zini

(President & CEO)

1. Technical data

GOPAVR-GOPAVRS power supply 

24 V

GOPAVT  power supply 

3 V type CR123A 

lithium 

battery

GOPAVR-GOPAVRS absorption 

60 mA max

GOPAVT absorption  

<100 μA (average value)

Frequency

 

868,95 MHz (JR2=ON)

869,85 

MHz 

(JR2=OFF)

Power  

<10 mW

Range  

20 m max

Output contact   

24 V   / 1A (resistive load)

Termination resistance 

8,2 kΩ

Operating temperature  

-20° C - +55° C

Degree of protection 

IP55

2. Applications

The GOPAV radio system for sensitive edges is intended for use as a 

safety device for motorized vertical doors or gates in conjunction with 

SOF sensitive edges. The system can be connected to the IN1 and/or IN2 

inputs which can be found both on the fixed GOPAVR-GOPAVRS unit as 

well as on the mobile GOPAVT unit.

The fixed GOPAVR-GOPAVRS unit can manage up to 5 mobile GOPAVT 

units. The fixed unit’s OUT1 and OUT2 outputs are respectively activated 

by the IN1 and IN2 inputs, which can be found on both the fixed unit itself, 

as well as on each mobile unit associated with it.

The fixed GOPAVR-GOPAVRS unit is also equipped with SAFETY TEST 

terminal 41. The mobile GOPAVT units are equipped with batteries and 

do not have to be connected to a control panel. Whenever the sensitive 

edges connected to each mobile GOPAVT unit are activated, due to the 

presence of an obstacle during opening or closing operations, the event 

is transmitted by radio to the fixed GOPAVR-GOPAVRS unit.

3. Installation conditions

-

The product must be used together with sensitive edges of a sufficient 

height to guarantee the the respect of the force limits provided for by 

the EN12453-EN12445 standards.

-

After every activation of the safety device, the gate control panel must 

cause a motion reversal for at least 0.5 s.

-

In order to comply with EN12453-EN12445 standards the product

must be tested at least once per monouvre cycle applying a negative 

polarity impulse to terminal 41 as indicated in the figure.

NOTE: when terminal 41 is not connected to the relative terminal on 

the control panel, LED indicators SC and OC on the fixed unit remain 

lit.

-

The time until the door or gate leaves the same end position again

shall be more than 20 s.

-

A normal door or gate movement shall not start if a safety output is

not switched on within 5 s after the test input is switched on again.

-

Up to 5 moving units can be installed in one system.

-

To comply with legal requirements concerning occupation of the

radio transmission band, according to the number of moving units

in the system, the trigger limits for the installed safety edges must

be complied with as in the values in the table below.

Mobile units

Max. number safety edge operations per hour

1

360

2

360

3

360

4

240

5

120

-

It is very important to ensure there is good communication between 

the various moving units and the corresponding fixed unit.

The values shown in the table refer to optimum communication con-

ditions. If communication is disturbed or inefficient, the maximum

number of operations allowed may be lower than the values shown

in the table.

-

In order to ensure sufficient radio capacity, the GOPAV devices must 

not be installed within any type of metallic casing.

4. Installation

-

The fixed GOPAVR unit must be either wall-mounted or otherwise

mounted on upon an appropriate support near the control panel.

-

The GOPAVRS fixed unit must be inserted in one of the AUX ports on 

the control panel or in the CONT1 card-holder base.

-

One or more mobile GOPAVT units must be mounted directly upon

the wing of the gate or door and each must be connected to one or

two SOF sensitive edges, as shown in fig. 2-3-4.

5. Electrical connections

Perform the electrical connections as indicated in fig. 2-3-4. 

Remove the terminating resistor from the IN1 or IN2 terminal to be used 

and connect the relative SOF sensitive edges to the terminal. 

The terminating resistors must not be removed from any inputs which 

are not being used.

WARNING: the use of the SAFETY TEST function through terminal 

41 is obligatory for compliance with the EN12453-EN12445 stan-

dards. Control panels without terminal 41 can be used by making a 

jumper for terminals 1-41 on the GOPAVR-GOPAVRS fixed unit and ope-

ning the JR1 jumper on the GOPAVRS unit only. In this case, however, the 

system 

WILL NOT BE COMPLIANT WITH THE EN12453-EN12445 STAN-

DARDS

.

6. Configuration

WARNING: remove the batteries from all of the mobile units be-

fore proceeding with the configuration.

Configure the devices as indicated:

-

connect the fixed GOPAVR-GOPAVRS unit to its electrical power supply, 

normally W LEDs will flash and output contacts OUT1 and OUT2 will 

be open;

-

check terminal 41 is correctly connected to the corresponding ter-

minal of the control panel;

-  insert the mobile GOPAVT unit’s battery into its appropriate lodging, 

all of the LED indicators on the mobile unit will flash;

-

press button A on the fixed GOPAVR-GOPAVRS unit, the W LED in-

dicators on the fixed unit with turn on and the OC LED indicators on

the mobile unit will flash;

-  press button A on the mobile GOPAVT unit, the LED indicators on the 

mobile unit and the fixed unit will turn off;

-

check for proper confi guration by activating the sensitive edge in ques-

oper configuration by activating the sensitive edge in ques-

tion: check that the fixed GOPAVR-GOPAVRS unit’s W LED indicator

turns on and check that the mobile GOPAVT unit’s IN LED indicator

turns on in relation to the output to which the sensitive edge is con-

Test input 

terminal 41

Safety output

(OUT1-OUT2)

Safety output

(OUT1-OUT2)

Test

0

24V

max 400 ms

~5 s

Detection

Test fails

ENGLISH