Ditec EL34

Control panel installation manual for QIK80EH barrier

(Original instructions)

Saf

ety r

eopening

Saf

ety r

eopening

Automation status lamp

-

+

Output 24 V= / max 0,5 A

Power suppl

y

BA

TKH

Flashing light

Lighting kit

Automatic cl

osing

Opening

Cl

osing

Stop

RDX

MD2

GOLR

POWER

ALARM

SA

11

IN

12

VA VC TC R1 CB

AUX

24V~

0 1 2 3 4 9

0 1 G1 G3

0 1 21 22

0 1 8

C NO

TRF

L N

14 0

PRG

COM

ENC

AUX

1

ON

2 3 4 5

EL34

SIG

Transformer

24V=             

Motor

BAT

+G2-

11

12

0

F1

FU

SE

BIXMR2

Limit switch

Limit switch Saf

ety switch

GOL4

+

M

-

Содержание Ditec EL34

Страница 1: ...us lamp Output 24 V max 0 5 A Power supply BATKH Flashing light Lighting kit Automatic closing Opening Closing Stop RDX MD2 GOLR POWER ALARM SA 11 IN 12 VA VC TC R1 CB AUX 24V 0 1 2 3 4 9 0 1 G1 G3 0 1 21 22 0 1 8 C NO TRF L N 14 0 PRG COM ENC AUX 1 ON 2 3 4 5 EL34 SIG Transformer 24V Motor BAT G2 11 12 0 F1 F U S E BIXMR2 Limit switch Limit switch Safety switch GOL4 M ...

Страница 2: ...th presence detection 32 13 Example of application for automations with two way operating mode 33 Key All the rights concerning this material are the exclusive property of Entrematic Group AB Although the con tents of this publication have been drawn up with the greatest care Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publicatio...

Страница 3: ...eveloped by the automation Before connecting the power supply make sure the plate data correspond to that of the mains power supply An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in the mains supply Check that there is an adequate residual current circuit breaker and a suitable overcur rent cut out upstream of the electrical installation in accordance with Goo...

Страница 4: ...14 02 2013 Marco Pietro Zini President EA 2 EC Declaration of Conformity 3 Technical specifications QIK80EH Power supply 230 V 50 60 Hz F1 fuse F2A Motor output 24 V 16 A Accessories power supply 24 V 0 5 A Temperature min 20 C max 55 C min 35 C max 55 C with NIO ac tivated min 10 C max 50 C with batteries Degree of protection IP55 Radio frequency 433 92 MHz Storable transmitters 200 3 1 Applicati...

Страница 5: ...and plug in cards in the AUX1 AUX2 and RDX housings are disabled 1 G1 N C REVERSAL SAFETY CONTACT Opening the safety contact triggers a reversal of the movement reopening during the closing operation PRG N O TRANSMITTER STORAGE AND CANCELLATION WARNING the storage module MUST BE inserted Transmitter storage press the PRG key the SIG LED turns on proceed with transmission from the transmitter to be...

Страница 6: ...on when the automation is open The light flashes with a variable frequency while the automation is operating ANT BIXAL If the GOLR radio receiver is used connect the supplied antenna wire 173 mm or alternatively the BIXAL antenna using a coaxial cable type RG58 0 1 21 22 MD2 DMCS Allows connection of the MD2 display module for advanced control of the functions or connection of the DMCS software RD...

Страница 7: ...echargeable batteries is approximately 5 C 40 C 6 Settings 6 1 Trimmers Trimmer Description VA VC MAX MIN VA Opening speed adjustment Adjusts the opening speed VC Closing speed adjustment Adjusts the closing speed TC MIN 0 s 60 s 10 s MAX 120 s Setting automatic closing time From 0 to 120 s R1 MAX MIN Thrust adjustment on obstacles The control panel is equipped with a safety device that stops moti...

Страница 8: ...n idle prevents all operations DIP4 FUTURE USE DIP5 Electronic antifreeze system Maintains motor efficiency even at low ambient temperatures Enabled Disabled 6 3 Signals LED On Flashing POWER 24V power supply Encoder not working Current overload on flashing light output Shortcircuiting of flashing light driver SA Indicates that at least one of the safety contacts is open IN Activated at every comm...

Страница 9: ... exit the procedure 10 seconds after the last transmission or you can press the PRG key again the SIG LED goes off Up to four CH keys of a single remote control can be stored If only one any CH key of the remote control is stored command 1 3 step by step opening is carried out If 2 4 CH keys of a single remote control are stored the functions matched with the CH keys are as follows CH1 command 1 3...

Страница 10: ...heck the automation is operating correctly with the subsequent opening and closing commands Check that the limit switches are activated Connect the safety devices removing the relative jumpers and check they function cor rectly If required activate automatic closing with command 1 2 and adjust the time with the TC trimmer Set the desired opening and closing speeds with the VA and VC trimmers Adjus...

Страница 11: ...rk Check that contact 1 2 is closed The external safety devices are not activated Incorrect connections between the photocells and the control panel Connect NC safety contacts together in series and remove any jumpers on the control panel terminal board The automation opens closes briefly and then stops Encoder disconnected false encoder contacts encoder fault flashing POWER ALARM LED Check that t...

Страница 12: ... closing operation at the same time as the time set with the TC trimmer of automation A expires 6 Only one GOLR radio receiver should be installed 7 If QIKLUX lighting kits are present set AP G2 03 or AP G2 02 to synchronise the lighting with the closed automations 10 Example of application for parallel automa tions MD2 A B 0 1 2 3 4 9 0 1 G1 G3 0 1 21 22 0 1 8 MD2 0 1 2 3 4 9 0 1 G1 G3 0 1 21 22 ...

Страница 13: ...n function PG can be enabled if a vehicle arrives in the same direction while another one is still between the barriers BC PG ON A second opening command is stored and executed as soon as the cycle in progress terminates MD2 A B 0 1 2 3 4 9 0 1 G1 G3 0 1 21 22 0 1 8 MD2 0 1 2 3 4 9 0 1 G1 G3 0 1 21 22 0 1 8 Stop Opening Automatic closing Safety reopening Safety reopening Opening Automatic closing ...

Страница 14: ...e with presence detection MD2 A B 0 1 2 3 4 9 0 1 G1 G3 0 1 21 22 0 1 8 MD2 0 1 2 3 4 9 0 1 G1 G3 0 1 21 22 0 1 8 Stop Opening Automatic closing Safety reopening Safety reopening Opening Automatic closing Stop VA VC TC R1 CB VA VC TC R1 CB 1 ON 2 3 4 5 1 ON 2 3 4 5 11 12 0 Limit switch Limit switch Safety switch 11 12 0 Limit switch Limit switch Safety switch DIP1 ON DIP1 ON For the connections re...

Страница 15: ... g LAN60 to terminals 1 3 3 Connect the safety device to terminals 1 8 4 Insert the LAB9 card on AUX1 5 Enable automatic closing with jumper 1 2 6 Adjust the TC trimmer 7 Set DIP1 ON 8 Set the delay time TO 9 Immediate reclosing of the barrier is possible BA TS 00 Exiting vehicles open the barrier with the AUX1 command We recommend setting AP D8 LO to prevent unauthorised access MD2 0 1 2 3 4 9 0 ...

Страница 16: ...IP2152EN 2015 03 16 Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www ditecentrematic com ...