background image

Ditec EL21

Control panel installation manual for Ditec VALORR-TENR  

automations installed in escape routes

www.ditecentrematic.com

IP2149EN

MOT +-

+

-

+

-

OPEN

POWER

ALARM

SA

REMOTE

Auxiliary opening

Key-operated opening

Emergency opening

Install the supplied ferrites 

as shown

GENERAL

PURPOSE

INTERNAL

SENSOR

EXTERNAL

SENSOR

OPEN

SAFETY

BUZZER

Closing safety device, outer side

Outer side opening

24V output    0,5 A

Opening safety device

Opening safety device

ROTARY 

FUNCTION

SELECTOR

IN

LK

AUX

AUX

BAT

POWER

ENC

BAT

Key-operated closing

Closing safety device, inner side

Opening, inner side

X

X

X

X

X

X

MD1

COMER

1

4

5

6

3

2

X

BIXMR2

24V=

Motor

Power supply

Transformer

24V output    0,5 A

+

+

-

-

MOT2+-

+

0LN

F1

FU

SE

0R1

SR

R2

1

ON

2 3 4

0 1 R- R+ 8A 41

1 2 A B 9 2729

0 1 3B 8B 41

0 1 6A 6B 41

0 1 2122

1 KOKC

1 G1 G2

1 EO 1 AO

Содержание Ditec EL21

Страница 1: ...ERNAL SENSOR OPEN SAFETY BUZZER Closing safety device outer side Outer side opening 24V output 0 5 A Opening safety device Opening safety device ROTARY FUNCTION SELECTOR IN LK AUX AUX BAT POWER ENC BAT Key operated closing Closing safety device inner side Opening inner side X X X X X X MD1 COMER 1 4 5 6 3 2 X BIXMR2 24V Motor Power supply Transformer 24V output 0 5 A MOT2 0 L N F1 F U S E 0 R1 SR ...

Страница 2: ...sensor 31 10 Start up 32 11 Troubleshooting 33 Key i This symbol indicates useful information for the correct functioning of the product This symbol indicates instructions or notes regarding safety to which special atten tion must be paid All the rights concerning this material are the exclusive property of Entrematic Group AB Although the contents of this publication have been drawn up with the g...

Страница 3: ...forces developed by the automation Before connecting the power supply make sure the plate data correspond to that of the mains power supply An omnipolar disconnection switch with a contact opening distance of at least 3mm must be fitted on the mains supply Check that there is an adequate residual current circuit breaker and a suitable overcur rent cutout upstream of the electrical installation in ...

Страница 4: ...Voltage Directive 2006 95 EC Landskrona 01 12 2013 Marco Zini President CEO 2 EC Declaration of Conformity 3 Technical specifications Ditec EL21 Power supply 230 V 50 60 Hz F1 fuse F1A Motor output 24 V 5 A Power supply for accessories 24 V 0 5 A max Ambient temperature 20 C 55 C Degree of protection IP20 i N B The given operating and performance features can only be guaranteed with the use of DIT...

Страница 5: ...1 5 or H05RR F 3G1 5 type electric cable Con nect it to terminals L brown N blue yellow green inside the automation Secure the cable using a special cable clamp and remove the sheath only where the clamp is In the external automation section the connections to the mains power supply and any other low voltage wires 230V must be made on an independent channel separated from the chan nel of connectio...

Страница 6: ...0 1 21 22 0 1 6A 6B 41 0 1 R R 8A 41 1 2 A B 9 27 29 1 S1 S2 COMER MD1 EL21 1 KO KC 1 G1 G2 1 EO 1 AO BAT 230 V F1 F1 6A POWER SUPPLY UNIT L N MOTOR F10A red blue black black black black black black 1 4 5 6 3 2 2 P PI 1 2I 1I 1 OP KEY 1R MR POWER RESET DMCS jack DO NOT USE EXTERNAL SENSOR VALLOKB BATTERY INTERNAL SENSOR PAS024AMT blue black red DO NOT USE DO NOT USE DO NOT USE grey grey black blac...

Страница 7: ...2 3 4 0 1 3B 8B 41 0 1 21 22 0 1 6A 6B 41 0 1 R R 8A 41 1 2 A B 9 27 29 1 S1 S2 1 KO KC 1 G1 G2 1 EO 1 AO BAT 230 V F1 F1 6A L N MOTOR F10A red blue black black black black black black EXTERNAL SENSOR INTERNAL SENSOR PAS024AMT BATTERY COMKR MD1 blue black red DO NOT USE DO NOT USE DO NOT USE grey grey black black black black red black black 0 1 R R 1 8A 41 0 24V POWER RESET C NO NC 29 28 27 9 B A ...

Страница 8: ...ected as well as de scribed in section 9 Advanced command management is available with the MD1 display module See function 41 6B NC OPENING SAFETY DEVICE RH SIDE 1 EO NC EMERGENCY OPENING Opening the contact activates emergency opening operation This command is active in every situation also in NIGHT TIME CLOSURE mode and has prior ity over every other command When the contact has closed again the...

Страница 9: ...4 25 1 AO NO AUXILIARY OPENING Contact closure activates the opening operation If the operation as escape route is disabled it will be re enabled for 5 minutes or for the time set by the display module MD1 N B This command can be combined with a magnetic card reader for access to automated teller machines if the door is set to NIGHT TIME CLOSURE mode OPEN NO OPENING Press quickly to activate openi...

Страница 10: ...R It allows COMKR selector connection as described on page 25 N B connect terminals 21 22 REMOTE to the DMCS jack on the COMKR selector using a data transmission type shielded cable COM BIXMR2 This allows the functioning configurations to be saved us ing the function of the MD1 display module The saved configurations can be recalled via the function of the MD1 display module If the control panel i...

Страница 11: ... condition alarm appears on the display with 5 acoustic signals without performing an opening operation To charge the batteries connect the mains power and the battery kit at least 30 minutes before starting the system WARNING connect batteries as described on pages 24 and 25 to allow charging the battery kit must be connected to the control panel at all times Periodically check the efficiency of ...

Страница 12: ...light POWER Power supply on Encoder not working or automa tion faulty SA Indicates that at least one of the safety con tacts is open Safety test failure terminal 41 IN A total or partial opening command or clos ing command is received The dip switch or COMKR selector status changes SETTINGS RESET in pro gress BUZZER Event Effect Escape route test 1 acoustic signal every second Alarm signalling 5 a...

Страница 13: ...l PAS024AMT or equivalent If you use a PAS024AMT sensor make connections as indicated on pages 24 25 Check that the activation output is set to CURRENT 5 see PAS024AMT installation manual Autocontrolled safety devices can be connected as shown in the figure Set DIP10 ON on each PASAT3 A A B B 1 2 24V 3 4 5 6 1 2 24V 3 4 5 6 RED GREEN BLUE WHITE BROWN ORANGE RED GREEN BLUE WHITE BROWN ORANGE OPEN S...

Страница 14: ...ough the ferrite as shown on pages 24 or 25 check that the operating force and contact force between the door wing and the obstacle is lower than that indicated in the EN 16005 Standard once starting has been completed the installer shall supply all the information relating to au tomatic manual and emergency operating modes of the motorised door and must provide the user with the operating instruc...

Страница 15: ...open SA LED on Check terminals 6 and 8 of the control panel The radars are activated Make sure the radar is not sub jected to vibrations and does not make false readings or check the presence of moving objects within its range The automatic closing does not work Check jumper 1 2 and the po sition of the function selector switch if present The automation opens by itself The radars are instable or d...

Страница 16: ...IP2149EN 2014 10 06 Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www ditecentrematic com ...