background image

                                                                                                                                       

Service  and  Installation  Manual

 

2           

For warranty service, call 866-417-6140                                                       

CONTENTS

 

                                                                             

 

RECEIVING  &  INSPECTING  EQUIPMENT………………………………………..…………………2 

SPECIFICATIONS

…………………………………………………….……………………….………3 

INSTALLATION

………………………………………………………………………….…………..….4 

OPERATION………..……………………………………………………………………..……………5 

MAINTENANCE

……………………………………………………………………….……………….7 

All rights reserved. Reproduction without written permission is prohibited. 

Is a registered trademark of Entrée L.L.C. 

 

SERIAL NUMBER INFORMATION                                                                               

The serial number of all self-contained refrigerators and freezers is located inside the unit on the left hand 
side near the top on the inside wall. 

Always have the model and serial number of your unit available when calling for parts or service. 

This manual covers standard units only. If you have a custom unit, consult the customer service department 

at the number listed on the last page. 

RECEIVING AND INSPECTING THE EQUIPMENT                                             

Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not 
damaged while being moved into the building. 

1.  Visually inspect the exterior of the package and skid or container. Any damage should be noted and reported 

to the delivering carrier immediately. 

2.  If damaged, open and inspect the contents with the carrier. 
3.  In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment, 

notify the carrier. Notification should be made verbally as well as in written form. 

4. Request an inspection by the shipping company of the damaged equipment. This should be done within 10 

days from receipt of the equipment. 

5. Be certain to check the compressor compartment housing and visually inspect the refrigeration package. Be 

sure lines are secure and base is still intact. 

6. Freight carriers can supply the necessary damage forms upon request.   
7. Retain all crating material until an inspection has been made or waived. 

 

 

 

 

 

 

 

Содержание BB-1HD

Страница 1: ...se read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 I M P O R T A N T I N F O R M A T I O N R E A D B E F O R E U S E PLEASE SAVE THESE INSTRUCTIONS REV 20151208 ...

Страница 2: ...ipment is shipped crated care should be taken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that the exterior is not damaged yet upon openi...

Страница 3: ...U G BB 1HD G 115 60 1 2 3 4 56 1 5 495 3 5 115 5 15P BB 2HD G 115 60 1 3 8 7 12 1 4 628 4 59 155 5 15P BB 3HD G 115 60 1 3 8 11 31 1 4 628 4 76 203 5 15P BB 2SD 28 115 60 1 2 3 4 56 1 5 495 3 5 111 5 15P BB 2SD 38 115 60 1 3 8 7 12 1 4 628 4 59 150 5 15P BB 3SD 55 115 60 1 3 8 11 31 1 4 628 4 76 192 5 15P SOLID DOOR BACK BAR BOTTLE COOLER MODEL V Hz Ph AMPS STORAGE CAPACITY Cu ft HP BTU CHARGE OZ ...

Страница 4: ...above the unit Should it become necessary to lay the unit on its side or back for any reason allow at least 24 hours before start up so as to allow compressor oil to flow back to the sump Failure to meet this requirement can cause compressor failure and unit damage Leveling A level cabinet looks better and will perform better because the doors will line up with the frames properly the cabinet will...

Страница 5: ...the bottom shroud Defrosting This unit will automatically go into defrost six times every 24 hour period To put the unit into manual defrost see instructions below SOLID STATE THERMOSTAT DESCRIPTIONS 1 FRONT PANELCOMMANDS To display target set point in programming mode it selects a parameter or confirms an operation To start a manual defrost To view the last alarm occurrence in programming mode it...

Страница 6: ...10s 2 3 HOW TO START A MANUAL DEFFROST Push the key for more than 2 seconds and a manual defrost will start 2 4 HOW TO LOCK THE KEYBOARD 1 Hold the and keys for more than 3s 2 The POF message will be displayed and the keyboard will be locked At this point it will be possible only to see the set point or the MAX or Min temperature stored 3 If a key is pressed more than 3s the POF message will be di...

Страница 7: ...air Failure to maintain a clean condenser coil can initially cause high temperatures and excessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures Neglecting the condenser coil cleaning procedures will void any warranties associated with the compressor or cost to replace the compressor Never use a high pressure water wash for this cleaning pro...

Страница 8: ...cause them to become brittle and prevent proper seals Do not use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets can easily be replaced and don t require the use of tools or authorized service technicians The gaskets are Dart style and can be pulled out of the grove in the door and replaced by pressing the new one back into place...

Страница 9: ...s hermetically sealed compressor to be free from defects in both material and workmanship under normal and proper use and maintenance service for a period of three 3 additional years from the date of original installation but not to exceed five 5 years and three 3 months after shipment from the manufacturer Removal or defacement of the original Serial Number or Model Number from any Unit shall be ...

Страница 10: ...d out by a qualified refrigeration technician This form can be obtain by down load from our website www entree biz This form must be emailed in its completion with a copy of the original proof of purchase to john entree biz WHAT IS NOT COVERED BY THIS WARRANTY Entrée L L C sole obligation under this warranty is limited to either repair or replacement of parts subject to the additional limitations ...

Страница 11: ...RÉE L L C IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM INCORRECT SUPPLY VOLTAGE THE USE OF EXTENSION CORDS LOW VOLTAGE OR UNSTABLE SUPPLY VOLTAGE THE USE OF PIERCING VALVES IS PROHIBITED AND IF LEFT IN THE SYSTEM VOIDS ALL WARRANTIES THIS EQUIPMENT IS INTENDED FOR INDOOR USE ONLY NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR P...

Страница 12: ...Service and Installation Manual 12 For warranty service call 866 417 6140 ENTRÉE LLC 4673 OSBORNE DR SUITE I EL PASO TX 79922 www entree biz ...

Отзывы: