Figure 6. Cover Hole Plug and Retaining Nut
Mount the GL1 and Connect the Electrical
NOTE:
The FMK-SL (Sliding Gate) and the FMK-SW (Swing Gate)
mounting bracket kits are recommended for installing the GL1.
1.
IF
not using one of the recommended mounting bracket kits,
THEN
USE the included template to locate and install mounting
hardware.
2.
INSTALL the lock chassis using the top two lock chassis mounting
positions.
NOTE:
The following chart shows wire gauge sizing versus voltage
versus distance:
Distance
Gauge 12V Gauge 24V Distance
Gauge 12V Gauge 24V
100 FT
20 GA
22 GA
800 FT
12 GA
14 GA
200 FT
18 GA
20 GA
1500 FT
10 GA
10 GA
400 FT
14 GA
16 GA
2000 FT
8 GA
8 GA
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]