PROGRAMMING OPTIONS
There are several AK-21W programming options. For most
installations, the factory set default options are sufficient. The
keypad must be in Programming Mode to make these changes.
Select Door Sense or Inhibit Input Default: Door Sense
The input on Terminal Block TB1, Terminal #8 can be programmed for
DOOR
SENSE
or
INHIBIT
.
Select Request-to-Exit Output
Default: Main Relay
Sets which output activates when the Request-to-Exit input is grounded. This
output may be timed or toggled.
Press:
1
6
#
Output
#
Output
= Output to Activate (0-4)
1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output
Press:
1
0
#
Input
#
Input
= 0 for Door Sense, = 1 for Inhibit
When programmed for
DOOR SENSE
, if an open condition on the input occurs
before access is granted (with an entry code or with the request-to-enter input) a
FORCEDENTRY
output will occur. If anopenconditionremains 60seconds after
a relay activation for access, a
DOOR AJAR
output will occur.
When programmed for
INHIBIT
, a closed condition on the input will prevent
Relay #1 fromactivating when access is requested with an entry code.This mode
is typically used with an external timer to disable the access device at certain
times.
Select Forced Entry Output
Default: Output #3
Sets which output activates if the
DOOR SENSE
input opens before access is
granted. This output is not timed.
Press:
1
1
#
Output
#
Output
= Output to Activate (0-4)
1 = Main Relay 2 = Auxiliary Relay 3 = Output #3 4 = Output #4 0 = No Output
Select Door Ajar Output
Default: Output #4
Sets which output activates if the
DOOR SENSE
input stays open 60 seconds
after access is granted. This output is not timed.
Press:
1
2
#
Output
#
Output
= Output to Activate (0-4)
1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output
Select Keypad Lockout Output
Default: No Output
Sets which output activates when the keypad is “locked out” after too many
incorrect entry code attempts. The lockout time is 60 seconds.
Press:
1
3
#
Output
#
Output
= Output to Activate (0-4)
1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output
Main Relay On-time
Default: 2 Seconds
Sets the length of time the Main Relay activates when triggered.
Press:
2
1
#
Seconds
#
Seconds
= Output time in seconds (0-60)
Auxiliary Relay On-time
Default: 2 Seconds
Sets the length of time Auxiliary Relay activates when triggered.
Press:
2
2
#
Seconds
#
Seconds
= Output time in seconds (0-60)
Solid-state Output #3 On-time
Default: 2 Seconds
Sets the length of time Output #3 activates when triggered.
Press:
2
3
#
Seconds
#
Seconds
= Output time in seconds (0-60), 99 =Toggle Mode
Solid-state Output #4 On-time
Default: 2 Seconds
Sets the length of time Output #4 activates when triggered.
Press:
2
4
#
Seconds
#
Seconds
= Output time in seconds (0-60), 99 =Toggle Mode
Set Downlight On-Time
Default: 2 Minutes
Sets the time duration that the downlight remains on after a key press.
Press: 2 5 # Duration #
0 = Always off, 1 = 1 minute, 2 = 2 minutes, 3 = 3 minutes,
4 = 4 minutes, 99 = Always on
Beep Sounds on Keystrokes
Default: Yes
Selects whether or not the keypad beeps as each key is pressed.
Press:
4
0
#
Sound
#
Sound
= 1 forYes, = 0 for No
Select Keypad Active Output
Default: No Output
Sets which output activates when any keys are pressed. This output is timed. If
toggle mode is selected for the output, the timer value defaults to 2 seconds.
Press:
1
4
#
Output
#
Output
= Output to Activate (0-4)
1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output
Select Alarm Shunt Output
Default: No Output
Sets which output activates during the time access is granted. (Use this output
to shunt alarm contacts attached to the access door.) This output may be timed
or toggled.
Beep Sounds During Main Relay
Default: No
Selects whether or not the keypad beeps during Main Relay activation.
Press:
4
1
#
Sound
#
Sound
= 1 forYes, = 0 for No
Press:
1
5
#
Output
#
Output
= Output to Activate (0-4)
1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output
5
wwww.EntraPASS.com
8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]