Shading
Shades, Blinds,...
Shading devices, such as shades, blinds, tendas and other have to be connected to the
ENTIA
living system as shown in the block diagram below. As opposed to lighting installation
(previous chapter), shading
MUST NOT
be connected to the ENTIAliving Power Expander
EL-E801 and must instead be connected to the Power Expander EL-E1601. Note that on
the block diagram below, the elements and wiring for shading connection is highlighted.
Sens
Controller
EL-S01
Room Controller
EL-R02
DALI Converter
EL-CD01
Power Dimmer
EL-D01
MODBUS
Converter
EL-CA01
Power Supply
EL-PS01
Main Controller EL-M01
Power Expander EL-E801
Power Expander EL-E1601
Room Controller
EL-R02
STP
2x0.75
Shade 1-5
4 x 1,5