1. INTRODUCTION
1.1 About User Manual
This User Manual is designed to help you for quick installation of RG-6T. Before installation
and operation, please read this section very carefully.
1.2 Precautions for Safe Use and Installation
- Failure to follow those instructions will result in death or serious injury.
- Disconnect all power before working on equipment.
- When the device is connected to the network, do not remove the back panel.
- Do not try to clean the device with solvent or the like. Only clean the device
with dried cloth.
- Verify correct terminal connections when wiring.
- Electrical equipment should be serviced only by your component seller.
- Only for rack panel mounting.
- An F type fuse must be used and its current limit value must be 6A.
- No responsibility is assured by ENTES A.S or any of its subsidiaries
for any consequences arising out of the use of this material.
2. GENERAL
Power Factor Controllers are used for measurement and control of power factor control units
for central reactive power compensation. The Power Factor measured by RG-6T is compared
with the set point values and in order to provide necessary compensation, Power Factor
Controller switches capacitor banks ON and OFF automatically. RG-6T is a microcontroller
relay, designed for above application in 144x144 and 96x96 (only RG-6T) case for flush
mounting with rear plug-in connectors.
In addition to displaying the system’s Cos
ϕ
in Automatic
Operating Mode, RG-6T displays the RMS values of Voltage(V) and Current (I), Active
Power (W), Reactive Power (VAr) and Apparent Power (VA) of measuring phase.
3. FRONT PANEL SPECIFICATIONS
On the front panel of RG-6T, there are warning lights, display and 3 buttons for settings.
3.1 Buttons and Lights
1. 1,2,.........,12
: Shows the status of each capacitor steps.
2.SET Menu
: Shows the Menu options that correspond to the lights.
3. AUTO/MAN Light : If this light is continuously ON, RG-6T is in Automatic Mode. If it is
blinking, RG-6T is in Manual Mode. By pressing SET button 3
seconds, you enter to Menu and change operating Mode . (Refer
to: 5.1)
4. Cos
ϕ
Light
: By pressing SET button 3 seconds ; Cos
ϕ
Adjustment can be made
by selecting this light. (Refer to: 5.3).
In Automatic Mode, when Cos
ϕ
light is selected by pressing UP
and DOWN buttons, system’s Cos
ϕ
and ind/cap state is displayed.
(Refer to: 5.10)
5.TIME/PF Light
: By pressing SET button 3 seconds; you enter to Menu and Step
Time adjustment is made by selecting this light. (Refer to: 5.4)
In Automatic Mode, when this light is selected by pressing UP and
DOWN buttons, system’s Power Factor is displayed. (Refer to: 5.11)
6.STEP/V Light
: By pressing SET button 3 seconds; you enter to Menu and Step
Number adjustment is made by selecting this light. (Refer to:5.5)
In Automatic Mode, when this light is selected by pressing UP and
DOWN buttons phase voltage (V) is displayed. (Refer to:5.12)
7. PROGRAM/I Light: By pressing SET button 3 seconds; you enter to Menu and Power
Sequence adjustment is made by selecting this light. (Refer to:5.6)
In Automatic Mode, when this light is selected by pressing UP and
DOWN buttons phase current (I) is displayed (Refer to:5.12)
8.C/k - W Light
: By pressing SET button 3 seconds; you enter to Menu and Manual
C/k adjustment is made by selecting this light.(Refer to:5.7)
In Automatic Mode when this light is selected by pressing UP and
DOWN buttons, system’s Active Power (W) is displayed.
(Refer to: 5.13)
9.CTR - VAr Light
: By pressing SET button 3 seconds; you enter to Menu and Current
Transformer Ratio adjustment is made by selecting this light.
(Refer to:5.8)
In Automatic Mode when this light is selected by pressing UP and
DOWN buttons, system’s Reactive Power (VAr) is displayed.
(Refer to: 5.14)
10.Over V. /VA Light : By pressing SET button 3 seconds; you enter to Menu and Protection
of Capacitor Steps Against Over Voltage function is made by selecting
this light. (Refer to:5.9)
In Automatic Mode when this light is selected by pressing UP and
DOWN buttons, system’s Apparent Power (VA) is displayed.
(Refer to: 5.15)
11.UP Button
: To move up in the Menu.
12.SET Button
: Enter button for different settings and values.
13.DOWN Button
: To move down in the Menu.
14.Automatic
C/k Setting
: Automatical C/k adjustment is started by pressing UP and DOWN
buttons together at the same time. (Refer to:5.2)
15. C+ Light
: This light is ON when RG-6T switches capacitor steps on.
16. NORMAL Light : This light is ON when the targeted compensation is achieved.
17. C- Light
: This light is ON when RG-6T switches capacitor steps off.
18.Insufficient
Compensation
Light
: This warning light is ON when insufficient compensation occurs.
(Refer to:6.1.2)
19.Over
Compensation
Light
: This warning light is ON when over compensation occurs.
(Refer to:6.1.3)
20.Over Voltage
Light
: This warning light is ON when over voltage occurs. (Refer to:6.1.1)
21.K (Kilo) Light
: When this light is ON displayed value must be multiplied by 1000.
22.M (Mega) Light
: When this light is ON displayed value must be multiplied by 10
6
.
4. CONNECTION DIAGRAM
Warnings:
a) Connection of a circuit breaker between the network and the power supply
input of the device is highly recommended.
b) Circuit breaker must be in close proximity to the device.
c) Circuit breaker must be marked as the disconnecting device for the equipment.
d) All used fuses must be FF type and the current values of the fuses must be
2A, 3A and 6A.
POWER FACTOR CONTROLLER
RG-6T
1
2
3
4
5
6
7
8
9
10
13
15
16
17
18
19
21
OVER V.
W
VAr
VA
11
14
20
M
12
22
Phase-Neutral Connection*
Phase-Phase Connection*
15
16
17
18
19
20
21
22
23
24 25
26
27
28
N
L3
L2
L1
C1
C6
C7
C12
6 A
6 A
11
12
Alarm Relay
3 A
1
2
3
4
2 A
5
6
k
l
K
L
1
RG-6T
L1
1
2
3
4
5
6
7
8
9 10 11
12 13 14
N
L3
L2