DIGITAL VOLTMETER

EVM-3 / EVM-3C / EVM-3S

PRECAUTIONS FOR INSTALLATION AND SAFE USE

Failure to follow those instructions will result in death or serious injury.

  Disconnect all power before working on equipment.

  When the device is connected to the network, do not remove the front

panel.

  Do not try to clean the device with solvent or the like. Only clean the

device with a dried cloth.

  Verify correct terminal connections when wiring.

   Electrical equipment should be serviced only by your compedent seller.

No responsibility is assured by the manufacturer or any of  its subsidiaries

for  any  consequences  arising  out  of  the  use  of  this  material.

  Only for rack panel mounting.

Warning :

a) A switch or circuit breaker must be connected between the network
      and the auxiliary supply input of device.

b) Connected switch or circuit breaker must be in close proximity to the

     device.

c) Connected switch or circuit breaker must be marked as the

disconnecting     device for the equipment.

d) The type of the used fuse must be FF type and the current of the used

    fuse must be 1A.

e) No need of a vantilator in the installation area

f ) Do not use with generator

g) Attach the instruction of practical using to the rack panel

EVM-3S (72x72) & (48x96) use 3-4 Terminals (L1-N) for supply input.

Thus L1-N voltage must be in operating voltage range (

D

U).

Connection Diagrams

!

“ISO 9001 Q.M.S. Certificate”

Technical Data

Operating Voltage (Un),

*

     Operating Range(

D

U) 

: Please look at labels on the device.

     Operating Frequency(f)

: 50/60 Hz

Accuracy

: 1% ±1 digit [(%10-%100) full scale]

Measuring  Input (Vin)

: 10-600 V AC  (for EVM-3, EVM-3C)

  

10-300 V AC (Phase-Neutral) (for EVM-3S)

  10-500 V AC (Phase-Phase) (for EVM-3S)

Measuring Category

: CAT III

Power Consumption(Pcons) : <4 VA
Burden 

: <1 VA (per phase)

Output Contact

: 5 A, 250 V, 1250 VA (Resistive) (for EVM-3C)

Ins. Tripping

: 1.5 x Setpoint (for EVM-3C)

Hysteresis

: 4% x Setpoint (for EVM-3C)

Delay Time

: 0.0 - 99.9 sec. (for EVM-3C)

Equipment Protection

: Double Insulation (      )

Box Protection Class

: IP 40

Terminal Block
Protection Class

: IP 00

Enclosure

: Non-flammable

Ambient Temperature

: -5 

O

C; +50 

O

C

Wire Thickness
(for terminal block)

: 2.5mm

2

Installations

: Flush mounting with rear terminals

Dimensions

: Type PR 18, PR 19, PR 20

Weight

: 0.28 kg    (for PR 18)
  0.30 kg    (for PR 19)
  0.25 kg    (for PR 20)

* Please check the device label for proper value.

*Different supply voltages are adjustable upon request.

Package Dimensions

: 32.5 x 22 x 18 cm

Pcs per Package

: 16 Pcs (for PR  18)

Package Weight

: 4.5 kg

Package Dimensions

: 27.5 x 24.5 x 25 cm

Pcs per Package

: 12 Pcs (for PR 19)

Package Weight

: 3.6 kg

Package Dimensions

: 30 x 23 x 17.5 cm

Pcs per Package

: 20 Pcs (for PR 20)

Package Weight

: 5 kg

Packaging Information

EVM-3S

(72x72)

(48x96)

N

1A

1A

1A

L1

L2

L3

4

2

3

1

1

2

EVM-3

1A

L

N

3

Measuring

Input

4

N

1A

1A

1A

L1

L2

L3

4

2

3

1

EVM-3S

(96x96)

5 6

L

1A

N

N

1

2

5

6

Output

Contact

EVM-3C

L

1A

3

Measuring

Input

4

64EVM000/02-05

Dimensions

The area Measurements on The Control Panel

TYPE PR 20 (48x96)

Wall

43mm

63mm
54 mm

50mm

90mm

79.3mm
70mm

TYPE PR 19 (96x96)

50mm

Wall

42mm

82.5mm

75mm

TYPE PR 18 (72x72)

50mm

65.5mm

Wall

Control Panel Cut Out

92mm

92mm

TYPE PR 19 (96x96)

68mm

68mm

TYPE PR 18 (72x72)

TYPE PR 20 (48x96)

96mm

48mm

TYPE PR 19 (96x96)

TYPE PR 20 (48x96)

TYPE PR 18 (72x72)

96mm

96mm

96mm

48mm

72mm

72mm