Xpedition SSR-ARE Installation Guide

Equipment Checklist

After unpacking the SSR-ARE, check the contents of the box to insure 
you’ve received the following items:

• One SSR-ARE line card

Handling the Module

C

AUTION

!

The SSR-ARE can easily be damaged by electrostatic discharge. To prevent 

electrostatic damage, observe the following guidelines:

• Do not remove the module from its packaging until you are ready to 

install it.

• Do not touch any of the module’s pins, connectors or components.

• Hold the module only by its edges or front panel.

• Wear an anti-static wristband connected to a suitable earth ground 

whenever handling the module.

• Store or transport this module only in appropriate anti-static 

packaging.

Installing the SSR-ARE

C

AUTION

!

The SSR-ARE line card is designed for the Xpedition 8000 (SSR-8) or 8600 

(SSR-16) only. Do not try to install these modules in any other units. For the 
Xpedition 8000, the SSR-ARE can be installed in any slot except 0 or 1. The 

SSR-ARE can be installed in any Xpedition 8600 slot except 0, 1 or 15. To 

install the module, use the following the instructions.

P

LEASE

 N

OTE

:

The SSR-ARE can be hotswapped into the Xpedtion 8000/8600 or installed 
with the power off.

1. Loosen the screws on the installed module or slot faceplate:

Using your fingers (or a phillips screwdriver), turn the screws used to 

secure the module (or faceplate) to the chassis in a counter-clockwise 
direction until they are free of the chassis.

2. Remove the installed module or faceplate:

Pull firmly on the screws until the module is free of the chassis. Carefully 
slide the module straight out of the slot. If you should remove the module, 

install the original faceplate to prevent dust and debris from entering the 

unit and to maintain proper air flow.

3. Insert the SSR-ARE into the Xpedition chassis:

Holding the new module with the text on the front panel upright, carefully 

slide the module into the slot and press gently until it snaps into place. Be 
sure the new module’s face plate is flush with the front panel.

4. Secure the new module:

Secure the Xpedition SSR-ARE module in place by turning the attached 
screws clockwise into the chassis. Finger tighten.