background image

Enterasys

®

 SecureStack

 C2

Gigabit and Fast Ethernet Switches

Hardware Installation Guide

C2G124-24
C2G124-48
C2H124-48

P/N 9033951-06

7.5x9-inch cover with bleed on 4 sides

Содержание SecureStack C2 C2G124-24

Страница 1: ...Enterasys SecureStack C2 Gigabit and Fast Ethernet Switches Hardware Installation Guide C2G124 24 C2G124 48 C2H124 48 P N 9033951 06...

Страница 2: ......

Страница 3: ...Inc 50 Minuteman Road Andover MA 01810 2008 Enterasys Networks Inc All rights reserved Part Number 9033951 06 February 2008 ENTERASYS ENTERASYS NETWORKS ENTERASYS MATRIX ENTERASYS SECURESTACK LANVIEW...

Страница 4: ...ss A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruit...

Страница 5: ...WEEE NOTICE In accordance with Directive 2002 96 EC of the European Parliament on waste electrical and electronic equipment WEEE 1 The symbol above indicates that separate collection of electrical an...

Страница 6: ...ove the relevant threshold of the SJ T 11363 2006 standard This table shows where these substances may be found in the supply chain of Enterasys electronic information products as of the date of sale...

Страница 7: ...r adjustment Class 1 Laser transceivers comply with the following safety standards 21 CFR 1040 10 and 1040 11 U S Department of Health and Human Services FDA IEC Publication 825 International Electrot...

Страница 8: ...xus House Newbury Business Park London Road Newbury Berkshire RG14 2PZ England Conformance to Directive s Product Standards EC Directive 89 336 EEC EN 55022 EN 61000 3 2 EN 61000 3 3 EN 55024 EC Direc...

Страница 9: ...OVISIONS THE LICENSE THE DISCLAIMER OF WARRANTY AND THE LIMITATION OF LIABILITY IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT OR ARE NOT AUTHORIZED TO ENTER INTO THIS AGREEMENT ENTERASYS IS UNWIL...

Страница 10: ...identified on the U S Commerce Control List or iii if the direct product of the technology is a complete plant or any major component of a plant export to Country Groups D 1 or E 2 the direct product...

Страница 11: ...dge and agree that any breach of Sections 2 4 or 9 of this Agreement by You may cause Enterasys irreparable damage for which recovery of money damages would be inadequate and that Enterasys may be ent...

Страница 12: ...x...

Страница 13: ...er 2 Network Requirements 10BASE TX Network 2 1 100BASE TX Network 2 2 1000BASE FX Network 2 2 1000BASE T Network 2 2 Chapter 3 Hardware Installation Considerations Prior to Installation 3 2 Required...

Страница 14: ...er Optic Cables to LC Ports 3 28 Completing the Installation 3 30 Chapter 4 Troubleshooting Using LANVIEW 4 2 Troubleshooting Checklist 4 6 Using the Reset Button 4 8 Appendix A Specifications Switch...

Страница 15: ...ght Wire Crossover Cable RJ45 Pinouts for 10 100 1000BASE TX 3 24 3 17 Eight Wire Straight Through Cable RJ45 Pinouts for 10 100 1000BASE TX 3 25 3 18 Cable Connection to MT RJ Multimode Fiber Optic C...

Страница 16: ...xiv...

Страница 17: ...the stackable switches Note In this guide the following terms are used Switch refers to all three switches C2G124 24 C2G124 48 and C2H124 48 unless otherwise noted MGBIC Mini Gigabit Interface Card re...

Страница 18: ...e describes how to use the Command Line Interface CLI to set up and manage the C2 switches Cabling Guide provides information concerning network cabling dB loss and other cabling specifications and us...

Страница 19: ...ns against an action that could result in personal injury or death due to an electrical hazard Riesgo Electrico Advierte contra una acci n que pudiera resultar en lesi n corporal o la muerte debido a...

Страница 20: ...xviii About This Guide...

Страница 21: ...ICs for 1000BASE T compliant copper connections or 1000BASE SX LX fiber optic connections The switches also support the use of a redundant DC power supply to help prevent downtime due to an internal p...

Страница 22: ...2RPS PSM Cable The 10 100 1000 Mbps fixed front panel ports can operate in either half duplex or full duplex mode as determined by Auto Negotiation Caution The C2G124 24 and C2G124 48 are not PoE comp...

Страница 23: ...Mbps ports 8 Reset switch 4 RJ45 port status LEDS 9 AC power input connector 5 Four slots for SFP interface modules Mini GBICs 10 Redundant power supply RPS DC connector Front Console 1 2 23 24 21 22...

Страница 24: ...tack C2 PoE Redundant Power System C2RPS POE to the DC power connector Otherwise damage to the device may result Precauci n El dispositivo C2H124 48 no cumple con el est ndar PoE No conecte una fuente...

Страница 25: ...nel RJ45 connectors and four uplink ports that support optional Mini GBICs At the time of this printing the six Mini GBICs that are available from Enterasys are described in Table 1 1 on page 1 5 Thes...

Страница 26: ...ck C2 Configuration Guide Standards Compatibility The switches are fully compliant with the IEEE 802 3 2002 802 3ae 2002 802 1D 1998 and 802 1Q 1998 standards The switches provide IEEE 802 1D 1998 Spa...

Страница 27: ...network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The device history that is have you returned the device before is th...

Страница 28: ...LANVIEW Diagnostic LEDs 1 8 Introduction...

Страница 29: ...ork installation must meet the requirements described in this chapter to ensure satisfactory performance of this equipment Failure to do so will produce poor network performance Note The SecureStack C...

Страница 30: ...SX compliant MT RJ fiber optic single mode connection MGBIC 08 for a 1000BASE ELX compliant LC fiber optic single mode connection The device at the other end of the fiber connection must meet the sam...

Страница 31: ...eis Installationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden Important Notice Read the Release Notes shipped with the switch to check for any exceptions to the sup...

Страница 32: ...pen the box and remove the packing material protecting the switch 2 Verify that the contents of the carton contains the items listed in Table 3 1 3 Remove the tape seal on the non conductive bag to re...

Страница 33: ...ver la potencia laser El uso de los instrumentos opticos para ver la potencia laser incrementa el riesgo a los ojos Cuando vean el puerto de la potencia optica la corriente debe ser removida del adapt...

Страница 34: ...port slot 2 Align the Mini GBIC with the port slot 3 Push the Mini GBIC into the port slot until the Mini GBIC clicks and locks into place Figure 3 1 Mini GBIC with MT RJ Connector Note If the Mini G...

Страница 35: ...discharges Use an antistatic wrist strap and observe all static precautions during this procedure Failure to do so could result in damaging the Mini GBIC or host switch Always leave the Mini GBIC in...

Страница 36: ...it straight out of the port slot If storing or shipping a Mini GBIC which has a fiber optic connector insert its protective dust cover to protect the ends of the fiber optic fibers from dust or conta...

Страница 37: ...cations 5 After installing the rubber feet return the switch to its upright position 6 Proceed to Guidelines for Installation on page 3 8 For a rackmount installation proceed to Rack Mounting the Swit...

Страница 38: ...ure 3 4 Area Guidelines for Switch Installation on Flat Surface Caution To ensure proper ventilation and prevent overheating leave a minimum clearance space of 5 1 cm 2 0 in at the left right and rear...

Страница 39: ...hour Caution To ensure proper ventilation and prevent overheating leave a minimum clearance space of 5 1 cm 2 0 in at the left right and rear of the switch Precauci n Para asegurar una buena ventilaci...

Страница 40: ...supplied Figure 3 6 Fastening the Switch to the Rack 3 If you are installing this switch in a stacked configuration repeat this procedure for each switch until all switches have been installed in the...

Страница 41: ...re the adjacent switches are two far apart for the short cables the long cable can be used for the connections C2CAB LONG cable to connect from the top switch to the bottom switch in the stack You onl...

Страница 42: ...scaled to help meet your network needs These switches provide a management platform and uplink to a network backbone for a stacked group of up to eight C2 switches 1 High speed stacking cable 4 STACK...

Страница 43: ...s disconnected from the stack The console port on the manager switch remains active for out of band local switch management but the console port on each member switch is deactivated This enables you t...

Страница 44: ...comes the Manager and all the next switches will join that stack regardless of Priority Firmware Revision or MAC Address The switches are assigned unit IDs in the order that you power on each switch 2...

Страница 45: ...outlet and power cord are country dependent Important Considerations About Using Clear Config in a Stack When using the clear config command as described in the SecureStack C2 Configuration Guide to c...

Страница 46: ...o start up If the switch is a stack Manager it can take up to 3 minutes or more to start up depending on the number of Member switches in the stack 1 AC power cord 2 AC power connector 3 Connector for...

Страница 47: ...initializations one of the switches in the stack will illuminate its Manager LED indicating that it is the stack Manager The Manager LED on each Member switch will be off The hierarchy of the switches...

Страница 48: ...B25 female cable you can connect products equipped with a DB9 DTE male console port to a VT series terminal or VT type terminals running emulation programs for the VT series Using a DTE modem DB9 fema...

Страница 49: ...t to its Console port 2 Plug the DB9 female connector at the other end of cable into the communications port on the PC 3 Turn on the PC and configure your VT emulation package with the following param...

Страница 50: ...t to its Console port 2 Plug the DB25 female connector at the other end of the cable into the port labeled COMM on the VT terminal 3 Turn on the terminal and access the Setup Directory Set the followi...

Страница 51: ...d of the cable into the modem communications port 3 Turn on the modem and make sure the remote modem is ON 4 With your PC connected to the remote modem configure your VT emulation package with the fol...

Страница 52: ...ing devices to these ports such as a bridge repeater or router use a crossover cable To connect twisted pair segments to the switch refer to Figure 3 13 and proceed as follows 1 Ensure that the device...

Страница 53: ...hub devices A straight through cable is used to connect between switches or hub devices and an end user computer Refer to Figure 3 14 and Figure 3 15 for four wire RJ45 connections Refer to Figure 3...

Страница 54: ...r 10 100 1000BASE TX 1 RJ45 switch port 3 RJ45 to RJ45 straight through cable 2 Other device port 4 RX RX and TX TX connections These connections must share a common color pair 1 RJ45 device port 3 RJ...

Страница 55: ...lasers Do not use optical instruments to view the laser output The use of optical instruments to view laser output increases eye hazard When viewing the output optical port power must be removed from...

Страница 56: ...clicks into place Note Leave the protective covers in place when the connectors are not in use to prevent contamination Caution Do not touch the ends of the fiber optic strands and do not let the ends...

Страница 57: ...ntil it is on a Verify that the device at the other end of the segment is ON and connected to the segment b If there are separate fiber optic connections on the other device check the crossover of the...

Страница 58: ...adapter Advertencia Los Mini GBICS de fibra optica usan lasers de clase 1 No se debe usar instrumentos opticos para ver la potencia laser El uso de los instrumentos opticos para ver la potencia laser...

Страница 59: ...and In this case ensure that the transmit fiber optic strand is connected to the receive port and the receive fiber optic strand to the transmit port 4 Verify that a link exists by checking that the p...

Страница 60: ...or modem connection proceed as follows at the displayed startup screen 1 Enter rw Read Write for Username 2 At the Password prompt press ENTER RETURN 3 For details on how to configure the switch usin...

Страница 61: ...t customer service for repair For information about Refer to page Using LANVIEW 4 2 Troubleshooting Checklist 4 6 Using the Reset Button 4 8 Caution There is a risk of explosion if the battery is repl...

Страница 62: ...C2G124 48 RJ45 ports 45 through 48 4 RPS LED for redundant power source status 8 Link Activity LEDs for 1 Gbps Mini GBIC for 5 Manager LED C2G124 24 ports 21 through 241 1 These Mini GBIC ports will...

Страница 63: ...Mini GBIC 5 Manager LED ports 49 through 521 1 Unlike the C2G124 24 or C2G124 48 all 52 ports may be active at the same time Note The terms flashing blinking and solid used in Table 4 3 indicate the...

Страница 64: ...everal minutes the system may have a fatal error Contact Enterasys Networks for technical support Amber Solid Diagnostics are running If the LED remains amber for more than several minutes contact Ent...

Страница 65: ...rating as the Manager of the stack None RPS Off RPS not in use Internal power supply failure None If an RPS is connected to the switch and should be providing power perform the following 1 Ensure the...

Страница 66: ...itted by the interface None Figure 4 3 LANVIEW LEDs Continued LED Color State Recommended Action Table 4 1 Troubleshooting Checklist Problem Possible Cause Recommended Action All LEDs are OFF Loss of...

Страница 67: ...t station and the device are valid and operating If the problem continues contact Enterasys Networks for technical support Port s goes into standby for no apparent reason Loop condition detected Verif...

Страница 68: ...n to device management You can now logon to the switch via the Console port and assign a new password using the command line interface CLI 3 To access switch management from your local PC terminal or...

Страница 69: ...lowing Enterasys Networks reserves the right to change the specifications at any time without notice For information about Refer to page Switch Specifications A 2 Mini GBIC Input Output Specifications...

Страница 70: ...BASE TX 1000BASE T port is disabled C2G124 48 RJ45 ports 1 through 48 Forty eight 10BASE T 100BASE TX 1000BASE T compliant ports with auto sensing and auto negotiation via RJ45 connectors SFP ports 45...

Страница 71: ...et 5 71 kg 12 6 lb one module without packaging C2H124 48 Gross 6 52 kg 14 3 lb shipping carton containing one module Net 5 27 kg 11 6 lb one module without packaging Predicted hours for Mean Time Bet...

Страница 72: ...Specifications Item Specification MGBIC LC01 Provides one LC fiber optic multimode port that is compliant with the 1000BASE SX standard LC connector MGBIC LC03 Provides one LC fiber optic multimode po...

Страница 73: ...e Item Modal Bandwidth 850 nm Range 62 5 m MMF 160 MHz km 2 220 Meters 62 5 m MMF 200 MHz km 2 275 Meters 50 m MMF 400 MHz km 2 500 Meters 50 m MMF 500 MHz km 2 550 Meters Table A 5 MGBIC LC03 Optical...

Страница 74: ...Meters Table A 7 MGBIC LC09 Optical Specifications Item 62 5 m MMF 50 m MMF 10 m SMF Transmit Power minimum 11 5 dBm 11 5 dBm 9 5 dBm Receive Sensitivity 20 dBm 20 dBm 20 dBm Link Power Budget 8 5 dB...

Страница 75: ...the maximum cable length of the attached segment The Link Power Budget must not exceed those specified in this table The MGBIC 08 input power must not exceed 3 dBm Otherwise saturation could occur 23...

Страница 76: ...magnetic compatibility EMC requirements listed in Table A 12 1 Pin 2 Received Data input 3 Pin5 Signal Ground 2 Pin 3 Transmitted Data output All other pins not connected 5 1 9 6 Table A 12 Compliance...

Страница 77: ...ont panel 1 3 1 4 H High Speed Stack Connections introduction to 1 5 High speed stacking cables installation of 3 11 I Installation connecting to the network 3 22 high speed stacking cables 3 11 in a...

Страница 78: ...8 A 2 MGBIC 02 A 7 MGBIC 08 A 7 MGBIC LC01 A 5 MGBIC LC03 A 5 MGBIC LC09 A 6 MGBIC MT01 A 5 Mini GBIC input outputs A 4 Stack initialization Manager switch selection 3 17 Stack Manager automatic selec...