background image

Matrix E1 Series

(1G58x-09 and 1H582-xx) 

WebView User’s Guide

9033782-01

Содержание Matrix E1 1G582-09

Страница 1: ...Matrix E1 Series 1G58x 09 and 1H582 xx WebView User s Guide 9033782 01 ...

Страница 2: ......

Страница 3: ...ENT WEB SITE OR THE INFORMATION CONTAINED IN THEM EVEN IF ENTERASYS NETWORKS HAS BEEN ADVISED OF KNEW OF OR SHOULD HAVE KNOWN OF THE POSSIBILITY OF SUCH DAMAGES Enterasys Networks Inc 50 Minuteman Road Andover MA 01810 2005 Enterasys Networks Inc All Rights Reserved Printed in the United States of America Order Number 9033782 01 September 2005 ENTERASYS NETWORKS ENTERASYS MATRIX WEBVIEW and any lo...

Страница 4: ...merce which prohibit export or diversion of certain technical products to certain countries unless a license to export the product is obtained from the U S Government or an exception from obtaining such license may be relied upon by the exporting party If the Program is exported from the United States pursuant to the License Exception CIV under the U S Export Administration Regulations You agree t...

Страница 5: ...umentation and media ENTERASYS DISCLAIMS ALL WARRANTIES OTHER THAN THOSE SUPPLIED TO YOU BY ENTERASYS IN WRITING EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE PROGRAM THE ACCOMPANYING WRITTEN MATERIALS AND ANY ACCOMPANYING HARDWARE 7 NO LIABILITY FOR CONSEQUENTIAL DAMAGES IN NO EVENT SHALL ENTER...

Страница 6: ......

Страница 7: ...paring to Use WebView 2 1 2 2 Starting WebView 2 2 2 3 WebView Security 2 2 2 4 Overview of the WebView User Interface 2 3 2 5 Navigating WebView 2 4 2 6 Port Designations in WebView 2 7 3 WEBVIEW LOCAL MANAGEMENT TASKS 3 1 Overview 3 1 3 2 System Screen 3 2 3 3 Switch Information Screen 3 4 3 4 IP Configuration Screen 3 5 3 5 SNMP Traps Configuration Screen 3 6 3 6 SNMP Community Names Screen 3 8...

Страница 8: ...Basic Information Screen 3 34 3 20 VLAN Current Table Screen 3 36 3 21 VLAN Static List Screen 3 38 3 22 VLAN Static Table Screen 3 39 3 23 VLAN Static Membership by Port Screen 3 42 3 24 VLAN Port Configuration Screen 3 43 3 25 IGMP Configuration Screen 3 45 3 26 IP Multicast Registration Table Screen 3 46 3 27 Port Information Screen 3 48 3 28 Port Admin Negotiation Configuration Screen 3 50 3 2...

Страница 9: ...figuration Screen 3 23 3 13 STA MST Instance Configuration Screen 3 25 3 14 STA Spanguard Configuration Screen 3 27 3 15 Bridge Extension Configuration Screen 3 29 3 16 Port Priority Configuration Screen 3 31 3 17 Port Traffic Class Information Screen 3 33 3 18 VLAN Basic Information Screen 3 35 3 19 VLAN Current Table Screen 3 36 3 20 VLAN Static List Screen 3 38 3 21 VLAN Static Table Screen 3 4...

Страница 10: ...reen Element Descriptions 3 28 3 15 Bridge Extension Configuration Screen Element Descriptions 3 29 3 16 Port Priority Configuration Screen Element Descriptions 3 32 3 17 Port Traffic Class Information Screen Element Descriptions 3 34 3 18 VLAN Basic Information Screen Element Descriptions 3 35 3 19 VLAN Current Table Screen Element Descriptions 3 37 3 20 VLAN Static List Screen Element Descriptio...

Страница 11: ...m initial device configuration and simple network management tasks STRUCTURE OF THIS GUIDE The guide is organized as follows Chapter 1 Introduction provides an introduction to WebView an overview of the Matrix E1 Local Management tasks that may be accomplished using WebView and information on how to contact Enterasys Networks for technical support Chapter 2 Starting and Navigating WebView provides...

Страница 12: ...s documents may help you to set up control and manage the Matrix E1 device Ethernet Technology Guide Cabling Guide Matrix E1 Series 1G58x 09 and 1H582 xx Installation Guide Matrix E1 Series 1G58x 09 and 1H582 xx Configuration Guide Documents listed above can be obtained from the World Wide Web in Adobe Acrobat Portable Document Format PDF at the following web site http www enterasys com DOCUMENT C...

Страница 13: ...intenance and troubleshooting through the WWW interface Access to Local Management via WebView is as simple as opening a URL in a web browser to the IP address of the Matrix E1 device WebView supports Netscape Navigator and Microsoft Internet Explorer with JDK 1 1 support Important Notices Depending on the firmware version used in the Matrix E1 1G58x 09 or 1H582 xx device some features described i...

Страница 14: ...way Assign a login password to the device for additional security Download a new firmware image Designate which network management workstations receive SNMP traps from the device View device and RMON statistics Enable ports to operate in standard or full duplex mode Configure ports to perform load sharing using trunking commands Set flow control on a port by port basis Configure ports to prioritiz...

Страница 15: ...description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you returned the device before is this a recurring problem etc Any previous Return Material Authorization RMA numbers World Wide Web http www enterasys com support Phone 1 800 872 8440 toll free in U S and Canada For the Enterasys Networks Support to...

Страница 16: ...Getting Help 1 4 Introduction ...

Страница 17: ... a console port as described in the Matrix E1 Series 1G58x 09 and 1H582 xx Installation Guide 2 Access the Command Line Interface CLI and use the CLI set IP command to configure an IP address for the device as described in the Matrix E1 Series 1G58x 09 and 1H582 xx Configuration Guide Example set ip address 10 42 42 111 mask 255 255 0 0 3 If necessary enable WebView and set the WebView port NOTE B...

Страница 18: ...w user interface Figure 2 2 displays 2 3 WEBVIEW SECURITY WebView security is administered with the use of SNMP community name strings and is limited to two access levels Read Only Allows users to view appropriate content available in WebView but does not allow them to modify any information Read Write Allows users access to full administrative privileges After the user enters the appropriate URL ...

Страница 19: ... a traditional frames presentation consisting of a navigation frame on the left side of the screen and a content frame on the right side of the screen The navigation frame allows you to select the available Matrix E1 information and configuration functions Screens in the content frame display the function selected from the navigation frame Figure 2 2 WebView User Interface ...

Страница 20: ...mmand Line Interface CLI to send email to Enterasys technical support and to connect to the Enterasys Web page Switch Go to the Switch Information screen where you can view information about the main system board including serial number number of ports and hardware and firmware versions IP Go to the IP Configuration screen where you can set the host IP state IP address subnet mask gateway IP addre...

Страница 21: ...rity per port view the number of egress traffic classes per port and view port priority to transmit queue mapping information VLAN Go to the VLAN Basic Information VLAN Current Table VLAN Static List VLAN Static Table VLAN Static Membership by Port and VLAN Port Configuration screens Here you can view basic information about the numbers of VLANs configured and about all static and dynamically crea...

Страница 22: ...ports from existing trunks Statistics Go to the Port Statistics screen where you can view port Ethernet like MIB statistics and RMON statistics Console Go to the Console Configuration screen where you can configure device console settings such as baud rate time out and auto refresh rate Apply entries made to the WebView screen on display Clear entries made to the WebView screen on display Go to We...

Страница 23: ...this printing and the location of the next consecutive port on each module Table 2 2 shows the numbering scheme for the fixed front panel and for each expansion module installed in various slots as it would appear in WebView screens with Port listings For information on how this device s port assignment scheme is expressed in CLI syntax and considerations necessary for configuring port mirroring a...

Страница 24: ...ple Consecutive Port Numbering for Optional Expansion Modules 2 1 4 6 8 10 12 14 16 3 5 7 9 11 13 15 18 17 20 22 24 26 28 30 32 19 21 23 25 27 29 31 34 33 36 38 40 42 44 46 48 35 37 39 41 43 45 47 Reset Console PWR CPU 1H582 51 Slot 2 65 80 Slot 3 81 96 Slot 1 49 64 25 26 33 34 10 9 18 17 2 1 41 42 1 48 3782_33 1G 2GBIC 3782_34 49 65 1G 2TX 81 1H 16TX ...

Страница 25: ...44 46 48 1H 16TX Expansion Module Sixteen fixed RJ45 ports Fast Ethernet 10 100BASE TX Installed in Slot 1 49 51 53 55 57 59 61 63 50 52 54 56 58 60 62 64 Installed in Slot 2 65 67 69 71 73 75 77 79 66 68 70 72 74 76 78 80 Installed in Slot 3 81 83 85 87 89 91 93 95 82 84 86 88 90 92 94 96 1G 2TX Expansion Module Two fixed RJ45 ports Fast Ethernet 1000BASE TX Installed in Slot 1 49 57 Installed in...

Страница 26: ...Port Designations in WebView 2 10 Starting and Navigating WebView ...

Страница 27: ...ion 3 7 Downloading a new firmware image from a TFTP server Section 3 8 Adding new static MAC and VLAN addresses and viewing the device s address table Section 3 9 Viewing and configuring Spanning Tree device and per port settings Section 3 10 through Section 3 15 Viewing the device s bridge extension settings Section 3 16 Configuring the device s port priority settings Section 3 17 and viewing po...

Страница 28: ...atistics Section 3 32 Configuring console settings such as baudrate time out and auto refresh time Section 3 33 3 2 SYSTEM SCREEN When to Use To view and configure system device settings such as the name and location of the device Links on this screen also enable you to Telnet to the textual Command Line Interface CLI to send email to Enterasys technical support and to connect to the Enterasys Web...

Страница 29: ...entifier for the device s network management subsystem Location See a name identifying the device location or enter a new location name The default is sysLocation Note that a name string containing a space in the text must be enclosed in quotes For example Bldg N32 Closet 9 Contact See a name identifying the contact person for the device or enter a new contact name The default is sysContact Note t...

Страница 30: ...tion screen Figure 3 2 displays Screen Example Figure 3 2 Switch Information Screen Screen Element Descriptions Refer to Table 3 2 for a functional description of each screen element Table 3 2 Switch Information Screen Element Descriptions Use this field To Serial Number See the serial number of the device s main board Number of Ports See the number of ports available on the device Hardware Versio...

Страница 31: ...ays Screen Example Figure 3 3 IP Configuration Screen Screen Element Descriptions Refer to Table 3 3 for a functional description of each screen element Table 3 3 IP Configuration Screen Element Descriptions Use this field To IP Address See or enter a new local host IP address Subnet Mask See or enter a new local host subnet mask Default is 255 255 0 0 Gateway IP Address See or enter a new gateway...

Страница 32: ...traps will be sent to enable or disable traps and to access the SNMP Community Names screen where SNMP community names and access policies associated with these traps can be set How to Access Click on SNMP on the WebView navigation frame The SNMP Traps Configuration screen Figure 3 4 displays Screen Example Figure 3 4 SNMP Traps Configuration Screen ...

Страница 33: ...NMP trap This identifies the network management station where SNMP alerts of status changes will be sent Trap Community Name Enter an SNMP community name to associate with the trap Community names act as passwords to remote SNMP management Enable Traps Enable or disable the SNMP traps associated with the displayed Trap Destinations and Trap Community Name Enable Authentication Traps Enable the dev...

Страница 34: ... SNMP community names and access policies How to Access Click on SNMP on the WebView navigation frame The SNMP Traps Configuration screen Figure 3 4 displays Click on SNMP Community Names on the content frame The SNMP Community Names screen Figure 3 5 displays Screen Example Figure 3 5 SNMP Community Names Screen ...

Страница 35: ...cess permission accorded each community name The available access levels are Read Only This community name gives the user read only access to the device MIB objects and excludes access to security protected fields of read write authorization Read Write This community name gives the user read write access to the device MIB objects and also gives super user access allowing the user to change all mod...

Страница 36: ...xample Figure 3 6 Security Configuration Screen Screen Element Descriptions Refer to Table 3 6 for a functional description of each screen element Table 3 6 Security Configuration Screen Element Descriptions Use this field To Old Password Enter the old login password or if none has been configured on the device leave this field blank By default at device start up no password is configured New Pass...

Страница 37: ...creen Example Figure 3 7 TFTP Download Management Screen Screen Element Descriptions Refer to Table 3 7 for a functional description of each screen element Table 3 7 TFTP Download Management Screen Element Descriptions Use this field or button To Server IP Address Enter the address of the TFTP server from which the new firmware image file will be downloaded Download Mode Accept the download mode R...

Страница 38: ...ddress entries remove entries and view counts of dynamic and static addresses in the address table How to Access Click on Address Table on the WebView navigation frame The Address Table Configuration screen Figure 3 8 displays Screen Example Figure 3 8 Address Table Configuration Screen Screen Element Descriptions Refer to Table 3 8 for a functional description of each screen element ...

Страница 39: ...the device is reset Delete on Reset Deletes all new static addresses when the device is reset Delete on Timeout Deletes all new static addresses when the device times out Add the new static address entry to the address table Remove a selected entry from the address table To select an entry click on it in the Address Table field Clear all entries in the device s address table Aging Time 10 630 Ente...

Страница 40: ...figuration STA Misc Port Config STA MST Instance Config and the STA Spanguard Config screens How to Access Click on STA on the WebView navigation frame The STA Information screen Figure 3 9 displays Spanning Tree information for the bridge device displays at the top Spanning Tree portion of the screen STA information about individual ports displays at the bottom Ports portion of the screen Screen ...

Страница 41: ... where the address is taken from the switch system Max Age See the maximum number of seconds 6 to 40 the bridge device will wait to receive a configuration message before attempting to reconfigure Hello Time See the maximum number of seconds 1 to 10 the device waits before sending a bridge hello message a multicast message indicating the device is active Forward Delay See the maximum number of sec...

Страница 42: ...abled The port is involved in an LACP group and is allowing STP to be handled by another port in the group usually the port with the lowest port number handles STP Blocked The port receives STA configuration messages but does not forward packets Listening The port will leave blocking state due to topology change will start transmitting configuration messages but does not yet forward packets Learni...

Страница 43: ...en some of them change state to listening to learning and then to forwarding Role Ports current role in Spanning Tree Forward Transitions See counts of the port s forward transitions Designated Cost See the path cost from the transmitting port to the root Designated Bridge See the MAC address of the designated bridge to which the port belongs This is the switch that is closest to the root switch t...

Страница 44: ...tings for the device including parameters for when the device becomes the Spanning Tree root bridge How to Access Click on STA on the WebView navigation frame The STA Information screen Figure 3 9 displays Click on STA Global Config on the content frame The STA Global Configuration screen Figure 3 10 displays Screen Example Figure 3 10 STA Global Configuration ...

Страница 45: ...de to Enabled Use Global Value or Disabled Use Per Port Values By default Bridge Hello Mode is enabled and uses the global hello time for all ports Topology Change Trap Suppress Use this command to disable or enable topology change trap suppression on Rapid Spanning Tree edge ports By default RSTP non edge bridge ports that transition to forwarding or blocking cause the switch to issue a topology ...

Страница 46: ... seconds at which the root device transmits a configuration message Maximum Age 6 40 Amount of time in seconds the root considers a BPDU packet to be valid Default is 20 seconds Forward Delay 4 30 Amount of time in seconds the root device spends in listening or learning mode Default is 15 seconds Table 3 10 STA Global Configuration Screen Element Descriptions Continued Use this field To ...

Страница 47: ... Cost and view the Operational Path Cost for each instance of Spanning Tree How to Access Click on STA on the WebView navigation frame The STA Information screen Figure 3 9 displays Click on STA MST General Configuration on the content frame The STA MST General Configuration screen Figure 3 11 displays Screen Example Figure 3 11 STA MST General Configuration Screen ...

Страница 48: ...ority and 61440 low priority Port See the port number associated with the displayed Spanning Tree port parameters Priority Enter a bridge priority value for the port This represents the priority of a link in a Spanning Tree bridge Valid values are from 0 to 240 in increments of 16 with 0 indicating high priority and 240 low priority Admin Path Cost Set a cost value to a Spanning Tree port This par...

Страница 49: ...anning Tree Algorithm STA settings for individual ports on the device How to Access Click on STA on the WebView navigation frame The STA Information screen Figure 3 9 displays Click on STA Misc Port Config on the content frame The STA Misc Port Configuration screen Figure 3 12 displays Screen Example Figure 3 12 STA Miscellaneous Port Configuration Screen ...

Страница 50: ... to True or False Authorized inter switch links should be set to false Spanguard if enabled only functions on ports with AdminEdge set to True typically set on user ports Admin Point Set the point to point status of the LAN attached to this specified port Options are True forces the port to be considered point to point False forces the port to be considered non point to point Auto default setting ...

Страница 51: ...figure Multiple Spanning Tree MST instances on the device How to Access Click on STA on the WebView navigation frame The STA Information screen Figure 3 9 displays Click on STA MST Instance Config on the content frame The STA MSTI Configuration screen Figure 3 13 displays Screen Example Figure 3 13 STA MST Instance Configuration Screen ...

Страница 52: ... zero Config Name Controls the MST Configuration Name Revision Level Controls the MST Revision Level Current Select to Remove New MST Instance 1 4094 To Add an MST Instance Input the MST Instance in the New field and press the Add button To Remove an MST Instance First map all FIDs to another configured instance Select the MST Instance s to remove from the current list and press the Remove button ...

Страница 53: ...d device wide and prevents any STA protocol use on unauthorized ports Ports with adminEdge set to True How to Access Click on STA on the WebView navigation frame The STA Information screen Figure 3 9 displays Click on STA Spanguard Config on the content frame The STA Spanguard Configuration screen Figure 3 14 displays Screen Example Figure 3 14 STA Spanguard Configuration Screen ...

Страница 54: ... the STP protocol is seen on a Port that has adminEdge set to True Spanguard Timeout Reception of a BPDU except loopback by a port with adminEdge set to True will cause the port to be locked and its state set to blocking Spanguard Timeout is how long in seconds that the port will remain locked The values are 0 65535 where 0 is forever Port Port The port number associated with the displayed Spangua...

Страница 55: ...e Extension Configuration screen Figure 3 15 displays Screen Example Figure 3 15 Bridge Extension Configuration Screen Screen Element Descriptions Refer to Table 3 15 for a functional description of each screen element Table 3 15 Bridge Extension Configuration Screen Element Descriptions Use this field To Extended Multicast Filtering Services See if filtering of individual multicast addresses is a...

Страница 56: ...ring database Configurable PVID Tagging See if you are allowed to override the default PVID setting Port VLAN ID used in frame tags and its egress status VLAN tagged or untagged on each port Local VLAN Capable See if the device supports multiple local bridges or Spanning Trees Host VLAN ID Enter the number of the VLAN designated as the host VLAN A host VLAN is a secure VLAN where only designated u...

Страница 57: ...ngress port priority per port to view the number of egress traffic classes or transmit queues per port and to access the Port Traffic Class Information screen How to Access Click on Priority on the WebView navigation frame The Port Priority Configuration screen Figure 3 16 displays Screen Example Figure 3 16 Port Priority Configuration Screen ...

Страница 58: ...ving a frame without priority information in its tag header is assigned a priority according to the priority setting on the port For example if the priority of a port is set to 5 the frames received through that port without a priority indicated in their tag header are classified as a priority 5 Default port priority is 1 Number of Egress Traffic Classes See the number of egress traffic classes or...

Страница 59: ... to transmit queue mapping information How to Access Click on Priority on the WebView navigation frame The Port Priority Configuration screen Figure 3 16 displays Click on Port Traffic Class Information on the content frame The Port Traffic Class Information screen Figure 3 17 displays Screen Example Figure 3 17 Port Traffic Class Information Screen ...

Страница 60: ...ys Table 3 17 Port Traffic Class Information Screen Element Descriptions Use this field To Port See the port number associated with the displayed priority parameters Priority 0 7 See the traffic class or transmit queue associated with priority levels 0 through 7 for each port 0 indicates that the priority has been assigned the lowest transmit queue priority and 3 indicates it has been assigned the...

Страница 61: ...formation Screen Element Descriptions Use this field To VLAN Version Number See the VLAN version used by the device as specified in the IEEE 802 1Q standard Maximum VLAN ID See the maximum number of VLAN IDs that can be recognized by the device Maximum Number of Supported VLANs See the maximum number of VLANs that can be configured on the device Current Number of 802 1Q VLANs Configured See the nu...

Страница 62: ...vice such as which ports belong to a VLAN s egress list and whether or not they are configured to transmit untagged frames How to Access Click on VLAN on the WebView navigation frame The VLAN Basic Information screen Figure 3 18 displays Click on VLAN Current Table on the content frame The VLAN Current Table screen Table 3 19 displays Screen Example Figure 3 19 VLAN Current Table Screen ...

Страница 63: ...reen Element Descriptions Use this field To VLAN Entry Delete Count See the number of times a VLAN entry has been deleted from this table VLAN ID Select the number identifying the VLAN for which to see port egress information Default is 1 Egress Ports See which ports belong to the VLAN s egress list Untagged Ports See which ports belonging to the VLAN are configured to transmit untagged frames ...

Страница 64: ...new or remove existing static VLANs from the device How to Access Click on VLAN on the WebView navigation frame The VLAN Basic Information screen Figure 3 18 displays Click on VLAN Static List on the content frame The VLAN Static List screen Figure 3 20 displays Screen Example Figure 3 20 VLAN Static List Screen ...

Страница 65: ...able on the content frame The VLAN Static Table screen Figure 3 21 displays Table 3 20 VLAN Static List Screen Element Descriptions Use this field or button To Current See the ID number s for currently configured VLANs and whether or not they are enabled or disabled VLAN ID 1 4094 Enter a unique number 1 to 4094 for the new VLAN to be created VLAN Name Enter a name 1 to 32 characters for the new o...

Страница 66: ...VLAN Static Table Screen 3 40 WebView Local Management Tasks Screen Example Figure 3 21 VLAN Static Table Screen ...

Страница 67: ...ke a selected Non Member port part of the Member egress list for the static VLAN Make a selected Member port part of the Non Member egress list for the static VLAN Forbidden Egress Ports Members See which ports belong to the static VLAN s forbidden egress list Frames containing a forbidden VLAN tag will be prevented from egressing from the specified port Non Members See which ports do not belong t...

Страница 68: ...AN Static Membership by Port on the content frame The VLAN Static Membership by Port screen Figure 3 22 displays Screen Example Figure 3 22 VLAN Static Membership by Port Screen Non Members See which ports are not configured to transmit untagged frames for a static VLAN Make a selected Non Member port part of the Member list of ports able to transmit untagged frames for the static VLAN Make a sele...

Страница 69: ...AN Basic Information screen Figure 3 18 displays Click on VLAN Port Configuration on the content frame The VLAN Configuration screen Figure 3 23 displays Table 3 22 VLAN Static Membership by Port Screen Element Descriptions Use this field or button To Port Number Select the number of the port for which to configure VLAN membership Member See the number and name of the VLAN of which the port is a m...

Страница 70: ...AN ID and ingress filtering status PVID 1 4094 Enter a Port VLAN ID 1 to 4094 Untagged frames received on the port will be assigned this VLAN number By default all ports are members of VLAN ID 1 the default VLAN Acceptable Frame Type See the acceptable frame type i e RIP the port is configured to transmit Ingress Filtering Enable or disable ingress filtering on the port This limits incoming frames...

Страница 71: ...escriptions Refer to Table 3 24 for a functional description of each screen element Table 3 24 IGMP Configuration Screen Element Descriptions Use this field To IGMP Status Enable or disable IGMP snooping on the device This allows a host to inform the device it wants to receive transmissions addressed to a specific multicast group IGMP Query Count 2 16 Enter the time in minutes 2 to 16 for the devi...

Страница 72: ...multicast transmissions its VLAN ID and the IP addresses of the ports asking to receive those transmissions as part of the IGMP group How to Access Click on IGMP on the WebView navigation frame The IGMP Configuration screen Figure 3 24 displays Click on IP Multicast Registration Table on the content frame The IP Multicast Registration Table screen Figure 3 25 displays Screen Example Figure 3 25 IP...

Страница 73: ...le Screen Element Descriptions Use this field To VLAN ID Select the identifying number of the VLAN configured for IGMP Multicast IP Address Select the IP address associated with the VLAN ID through which all multicast traffic is forwarded Learned by See the manner in which the address was learned Dynamic or IGMP Multicast Group Port List See the port s within this VLAN that wish to receive multica...

Страница 74: ...peed duplex and flow control status To access the Port Admin Negotiation Configuration Port Advertised Ability Configuration and Port Broadcast Suppression Configuration screens How to Access Click on Port on the WebView navigation frame The Port Information screen Figure 3 26 displays Screen Example Figure 3 26 Port Information Screen ...

Страница 75: ...has a valid link Up or Down Link status will be down until a link is established to an external device and the port is enabled Speed Status See the port s operational speed in Mbps 10M 100M or 1000M Duplex Status See the port s duplex mode Options are 10M Half Duplex 10M Full Duplex 100M Half Duplex 100M Full Duplex and Auto Negotiation Flow Control Status See the port s flow control status Enable...

Страница 76: ...w control administrative and duplex status How to Access Click on Port on the WebView navigation frame The Port Information screen Figure 3 26 displays Click on Port Admin Negotiation Configuration on the content frame The Port Admin Negotiation Configuration screen Figure 3 27 displays Screen Example Figure 3 27 Port Admin Negotiation Configuration Screen ...

Страница 77: ...nformation Admin Status Administratively Enable or Disable the port Auto Negotiate Enable or Disable Auto Negotiation on a Port by Port basis Speed Duplex Config Set the port s duplex mode Options are 10M Half Duplex 10M Full Duplex 100M Half Duplex and 100M Full Duplex Note This option is only available when Auto Negotiation is disabled Flow Control Config Set the port s flow control status Enabl...

Страница 78: ...t a port s speed duplex and flow control How to Access Click on Port on the WebView navigation frame The Port Information screen Figure 3 26 displays Click on Port Advertised Ability Configuration on the content frame The Port Advertised Ability Configuration screen Figure 3 28 displays Screen Example Figure 3 28 Port Advertised Ability Configuration Screen ...

Страница 79: ... Descriptions Use this field To Port See the port number associated with the displayed status information Adv 10M Set the Port to advertise or not 10M Half Duplex and or 10M Full Duplex Adv 100M Set the Port to advertise or not 100M Half Duplex and or 100M Full Duplex Adv 1G For Ports that support Gigabit Ethernet set the Port to advertise or not 1G Half Duplex and or 1G Full Duplex Adv Flow Ctrl ...

Страница 80: ...oadcast suppression on a port by port basis How to Access Click on Port on the WebView navigation frame The Port Information screen Figure 3 26 displays Click on Port Broadcast Suppression Configuration on the content frame The Port Broadcast Suppression Configuration screen Figure 3 29 displays Screen Example Figure 3 29 Port Broadcast Suppression Configuration Screen ...

Страница 81: ...t Descriptions Use this field To Port See the port number associated with the displayed status information Broadcast Suppression Enable or Disable Broadcast Suppression per port Threshold pps 1 1488100 Set the broadcast suppression limit in packets per second on one or more ports This sets a threshold on the broadcast traffic that is received and thus switched out to other ports Note the maximum v...

Страница 82: ...ATION SCREEN When to Use To add or remove trunks on the device and to add or remove trunk ports from existing trunks How to Access Click on Trunk on the WebView navigation frame The Port Trunking Configuration screen Figure 3 30 displays Screen Example Figure 3 30 Port Trunking Configuration Screen ...

Страница 83: ...name Enter a name for the trunk to be created Create a new trunk with the name specified Member List Current See a list of trunks and member ports currently configured on the device Trunk Select a trunk name to which to Add member ports or to Delete from the device Port Select a member port to add to the specified trunk Add the specified Port to the specified Trunk Member List Remove the specified...

Страница 84: ...32 PORT STATISTICS SCREEN When to Use To view port Ethernet like MIB statistics and RMON statistics How to Access Click on Statistics on the WebView navigation frame The Port Statistics screen Figure 3 31 displays Screen Example Figure 3 31 Port Statistics Screen ...

Страница 85: ...llision Multiple Collision Frames See a count of successfully transmitted frames for which transmission is inhibited by more that one collision SQE Test Errors See a count of times that the SQE TEST ERROR message is generated by the PLS sublayer Deferred Transmissions See a count of frames for which the first transmission attempt on a particular interface is delayed because the medium was busy Lat...

Страница 86: ...hat were directed to the multicast address This value does not include broadcast frames CRC Alignment Errors See the number of frames with bad Cyclic Redundancy Checks CRC received from the network The CRC is a 4 byte field in the data frame that ensures that the data received is the same as the data that was originally sent Undersize Frames See the number of frames received containing less than t...

Страница 87: ...he total number of frames including bad frames received that were between 128 and 255 bytes in length excluding framing bits but including FCS bytes 256 511 Bytes Frames See the total number of frames including bad frames received that were between 256 and 511 bytes in length excluding framing bits but including FCS bytes 512 1023 Bytes Frames See the total number of frames including bad frames re...

Страница 88: ...URATION SCREEN When to Use To configure device console settings such as baud rate time out and auto refresh rate How to Access Click on Console on the WebView navigation frame The Console Configuration screen Figure 3 32 displays Screen Example Figure 3 32 Console Configuration Screen ...

Страница 89: ...onfiguration Screen Element Descriptions Use this field To Baudrate Select the console baud rate Time Out Enter the time in minutes that must elapse before the device times out Databits Select the console s databits Stopbits Select the console s stopbits Parity Select the parity type Auto Refresh Time Enter the time in seconds that must elapse before the device console auto refreshes ...

Страница 90: ...Console Configuration Screen 3 64 WebView Local Management Tasks ...