Using LANVIEW
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide
4-3
Table 4
‐
2
describes
the
LED
indications
and
provides
recommended
actions
as
appropriate.
The terms
flashing
,
blinking
, and
solid
used in
Table 4-2
indicate the following:
•
Flashing
indicates
an LED is flashing randomly.
•
Blinking
indicates
an LED is flashing at a steady rate (approximately 50% on, 50%
off).
•
Solid
indicates
a steady LED light. No pulsing.
•
Alternating
indicates an LED is flashing in a steady rate other than 50% on, 50%
off.
Table 4-2 LANVIEW LEDs
LED
Color
State
Recommended Action
MGMT
None
Off
. This module is NOT the
Management Module.
None.
Green
Solid
. This module is the
designated Management
Module.
None.
Amber
Flashing
.
This is a
temporary
indication that the
module is saving data.
None.
CPU
None
Power off.
Ensure chassis has adequate power.
Amber
Blinking
. Module in process
of booting.
None.
Solid
. Testing.
If the LED remains amber for several
minutes, contact Enterasys Networks
for technical support.
Green
Blinking
.
Image starts
running.
None.
Solid
. Functional.
None.
Red
Solid
. Processor in reset.
None.
Green
and
Amber
Blinking
.
Indicates that the
module is in the process of
shutting down.
None. This state is activated when the
OFFLINE/RESET switch is pressed for
less than 1 second to a start the process
of an orderly shutdown.
While in this state, do not remove any
DFE-Platinum module.
Содержание Matrix 7G4282-41
Страница 2: ......
Страница 12: ...x...
Страница 16: ...xiv...
Страница 26: ...LANVIEW Diagnostic LEDs 1 6 Introduction...
Страница 64: ...Regulatory Compliance A 4 Specifications...
Страница 65: ...Regulatory Compliance Enterasys Matrix DFE Platinum Series Hardware Installation Guide A 5...
Страница 66: ...Regulatory Compliance A 6 Specifications...