background image

1

2

NOTICE

Enterasys Networks and its licensors reserve the right to make changes in specifications and other 
information contained in this document without prior notice. The reader should in all cases consult 
Enterasys Networks to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL ENTERASYS NETWORKS AND ITS LICENSORS BE LIABLE FOR ANY 
INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER 
(INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS 
MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF ENTERASYS NETWORKS 
AND ITS LICENSORS HAVE BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE 
POSSIBILITY OF SUCH DAMAGES.

Enterasys Networks, Inc.
35 Industrial Way
Rochester, NH 03866-5005

 2001 by Enterasys Networks, Inc.

All Rights Reserved
Printed in the United States of America

Order Number: 9033749 September 2001

X-Pedition and Enterasys Networks are registered trademarks of Enterasys Networks or its licensors. All 
other product names mentioned in this manual may be trademarks or registered trademarks of their 
respective companies.

FCC NOTICE

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 
(1) this device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, 
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial environment. This equipment uses, 
generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s 
manual, may cause harmful interference to radio communications. Operation of this equipment in a 
residential area is likely to cause interference in which case the user will be required to correct the 
interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the 
party responsible for compliance could void the user’s authority to operate the equipment.

INDUSTRY CANADA NOTICE

This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus 
set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux 
appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté 
par le ministère des Communications du Canada.

VCCI NOTICE

This is a class A product based on the standard of the Voluntary Control Council for Interference by 
Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio 
disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

CLASS A ITE NOTICE

WARNING: This is a class A product. In a domestic environment this product may cause radio 
interference in which case the user may be required to take adequate measures. 

DECLARATION OF CONFORMITY

Application of Council Directive(s):

89/336/EEC
73/23/EEC

Manufacturer’s Name:

Enterasys Networks, Inc.

Manufacturer’s Address:

35 Industrial Way
PO Box 5005
Rochester, NH 03867

European Representative Name:

Mr. Jim Sims

European Representative Address:

Enterasys Networks Ltd.
Nexus House, Newbury Business Park
London Road, Newbury
Berkshire RG14 2PZ, England

Conformance to Directive(s)/

Product Standards:

EC Directive 89/336/EEC
EC Directive 73/23/EEC
EN 55022
EN 55024
EN 60950
EN 60825

Equipment Type/Environment:

Networking Equipment, for use in a
Commercial or Light Industrial Environment.

Enterasys Networks, Inc. declares that the equipment packaged with this notice conforms to the above 
directives.

AGENCY STANDARDS

Safety

Meets the requirements of UL 1950, CSA C22.2 No. 950, EN 60950, IEC 950, 
73/23/EEC, and EN 60825.

Electromagnetic Compatibility

Compliant with the requirements of FCC Part 15, CSA C108.8, EN 55022, EN 61000-3-2, 
EN 61000-3-3, VCCI V-3, EN 55024, 89/336/EEC, and AS/NZS 3548.

ER16-SERC-04-AA

The ER16-SERC-04-AA Serial card provides wide area connectivity via 4 T1/E1 ports 
with compression. These ports have the same switching and routing capabilities as those 
provided by the ethernet line cards. The ports can switch at Layer-2, Layer-3, and Layer-4, 
and perform both destination-based and flow-based switching. All ports are capable of 
bridging at Layer-2, switching IP/IPX frames at Layer-3, and switching on Layer-4 flows.

SPECIFICATIONS

Ports

4 Serial ports with compression (up to 8MB per port)

ASIC Type

-AA (Advanced ASIC)

DMAC, IPP, OPP

Network Interfaces

60-Pin D-shell supporting 2 serial ports per connector

Physical Dimensions

Size: 52.9 cm H x 2.9 W x 40.1 D (20.9 in. H x 1.15 W x 15.8 D)

Weight: 2.72 kg (6.0 lbs)

Power Consumption

BTU/hr = 146.35

AC Volt Amps = 43.31

Temperature

Operating: 32° to 104° F (0° to 40° C) 
Storage: -22° to 194° F (-30° to 90° C)

Humidity

5% to 95% (non-condensing)

CONNECTIVITY GUIDELINES

LEDs

Table 1

Recommended Cable Types and Specifications

Cable

Type

Max. Length

Connector

Serial

V.35, EIA-530, EIA-449, X.21

60-Pin D-Shell

Table 2

LED Indicators

LED

Condition

Status

Online (2)

Green

The unit is operational and functioning properly.

Offline (2)

Amber

The unit is not operational. You may remove the 
unit from the chassis.

Tx (4)

Amber

A frame was transmitted.

Rx (4)

Amber

A frame was received.

Link (4)

Green

A valid link is established on the port.

Отзывы: