Using LANVIEW
Matrix DFE-Gold Series Modules Hardware Installation Guide 4-5
Table 4-1 LANVIEW LEDs
LED
Color
State
Recommended Action
MGMT
None
Off
. This module is NOT the
Management Module.
None.
Green
Solid
. This module is the
designated Management
Module.
None.
Amber
Flashing
.
This is a
temporary
indication that the
module is saving data.
None.
CPU
None
Power off.
Ensure chassis has adequate power.
Amber
Blinking
. Module in process
of booting.
None.
Solid
. Testing.
If the LED remains amber for several
minutes, contact Enterasys Networks
for technical support.
Green
Blinking
.
Image starts
running.
None.
Solid
. Functional.
None.
Red
Solid
. Processor in reset.
None.
Green
and
Amber
Blinking
.
Indicates that the
module is in the process of
shutting down.
None. This state is activated when the
OFFLINE/RESET switch is pressed for
less than 1 second to start the process
of an orderly shutdown.
While in this state, do not remove any
DFE-Gold module.
Amber
and Off
Alternately (67% on, 33%
off)
. Indicates that a
shutdown process has
completed. This indication
will remain for 60 seconds
before automatically
restarting.
While in this state, you have 60 seconds
to safely remove the DFE-Gold module
from the chassis.
Содержание DFE-Gold 4H4202-72
Страница 2: ......
Страница 12: ...x...
Страница 60: ...Completing the Installation 3 30 Installation...
Страница 88: ...Memory Locations and Replacement Procedures B 14 Mode Switch Bank Settings and Optional Installations...