Matrix DFE-Gold Series PoE Module 4H4285-49 Installation Guide 4-1

4

Troubleshooting

This

 

chapter

 

provides

 

information

 

concerning

 

the

 

following:

Using LANVIEW

The

 

DFE module

 

uses

 

a

 

built

in

 

visual

 

diagnostic

 

and

 

status

 

monitoring

 

system

 

called

 

LANVIEW.

 

The

 

LANVIEW

 

LEDs

 

(

Figure 4

1

)

 

allow

 

quick

 

observation

 

of

 

the

 

network

 

status

 

to

 

aid

 

in

 

diagnosing

 

network

 

problems.

 

About the Management (MGMT) LED

The

 

MGMT

 

LED

 

(shown

 

in

 

Figure 4

1

)

 

indicates

 

when

 

the

 

module

 

is

 

serving

 

as

 

the

 

Management

 

Module

 

to

 

control

 

the

 

management

 

functions

 

for

 

all

 

DFE

Gold modules

 

in

 

the

 

chassis.

 

The

 

Management

 

Module

 

handles

 

all

 

IP

 

requests

 

to

 

the

 

chassis

 

IP

 

address,

 

such

 

as

 

PING,

 

Telnet,

 

SNMP,

 

HTTP,

 

and

 

more.

 

The

 

Management

 

Module

 

also

 

handles

 

the

 

CLI

 

configuration

 

sessions

 

through

 

the

 

console

 

port.

 

So,

 

when

 

you

 

plug

 

into

 

a

 

DFE

Gold module

 

COM

 

port

 

to

 

configure

 

a

 

DFE

Gold module

 

in

 

the

 

chassis,

 

it

 

is

 

handled

 

by

 

the

 

Management

 

Module

 

regardless

 

of

 

the

 

DFE

Gold module

 

COM

 

port

 

that

 

you

 

use.

 

For information about...

Refer to page...

Using LANVIEW

4-1

Troubleshooting Checklist

4-7

Overview of DFE Module Shutdown Procedure

4-9

Recommended Shutdown Procedure Using OFFLINE/RESET Switch

4-10

Last Resort Shutdown Procedure Using OFFLINE/RESET Switch

4-10

Содержание 6H308-48

Страница 1: ...7 5x9 inch cover with bleed on 4 sides Enterasys Matrix DFE Gold Series Hardware Installation Guide PoE Module 4H4285 49 P N 9033989 06...

Страница 2: ......

Страница 3: ...2008 Enterasys Networks Inc All rights reserved Part Number 9033989 06 July 2008 ENTERASYS NETWORKS ENTERASYS MATRIX LANVIEW MATRIX ENTERASYS NETSIGHT WEBVIEW and any logos associated therewith are t...

Страница 4: ...s A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits...

Страница 5: ...lectrical and Electronic Equipment WEEE Notice In accordance with Directive 2002 96 EC of the European Parliament on waste electrical and electronic equipment WEEE 1 The symbol above indicates that se...

Страница 6: ...ous materials in the parts is above the relevant threshold of the SJ T 11363 2006 standard This table shows where these substances may be found in the supply chain of Enterasys electronic information...

Страница 7: ...VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions BSMI EMC Statement Taiwan This is a c...

Страница 8: ...of radiant power exiting the fiber under normal conditions is 12 6 dBm or 55 x 10 6 watts Removing the optical connector from the transceiver allows laser radiation to emit directly from the optical p...

Страница 9: ...F YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT OR ARE NOT AUTHORIZED TO ENTER INTO THIS AGREEMENT ENTERASYS IS UNWILLING TO LICENSE THE PROGRAM TO YOU AND YOU AGREE TO RETURN THE UNOPENED PRODUCT T...

Страница 10: ...st or iii if the direct product of the technology is a complete plant or any major component of a plant export to Country Groups D 1 or E 2 the direct product of the plant or a major component thereof...

Страница 11: ...edge and agree that any breach of Sections 2 4 or 9 of this Agreement by You may cause Enterasys irreparable damage for which recovery of money damages would be inadequate and that Enterasys may be en...

Страница 12: ...x...

Страница 13: ...Network 2 2 100BASE TX Network 2 2 Chapter 3 Installation Installation Site Requirement 3 2 Unpacking the DFE Module 3 2 Installing Optional Network Expansion Module NEM 3 3 DFE Module Placement and...

Страница 14: ...4 10 Appendix A Specifications 4H4285 49 Specifications A 1 COM Port Pinout Assignments A 3 Regulatory Compliance A 3 Appendix B Mode Switch Settings and Option Installations Required Tools B 1 Setti...

Страница 15: ...ompatible 3 19 3 10 Connecting a VT Series Terminal 3 20 3 11 Connecting Using a Modem 3 22 3 12 Matrix Defogged Startup Screen Example N7 Chassis 3 26 4 1 LANVIEW LEDs 4 2 4 2 OFFLINE RESET Switch 4...

Страница 16: ...xiv...

Страница 17: ...dule refers to the 4H4285 49 unless otherwise noted Network expansion module or NEM or refers to an optional uplink card installed on the main logic board and accessible through the option slot of the...

Страница 18: ...d cable specifications Unlike the Enterasys Matrix DFE Gold Series Configuration Guide and the Matrix N Series N POE Power System Installation Guide the Cabling Guide is not listed alphabetically on t...

Страница 19: ...Achtung Verwei t auf wichtige Informationen zum Schutz gegen Besch digungen Electrical Hazard Warns against an action that could result in personal injury or death due to an electrical hazard Riesgo...

Страница 20: ...ption of your network environment for example layout cable type Network load and frame size at the time of trouble if known The device history for example have you returned the device before is this a...

Страница 21: ...the firmware version used in the DFE module some features described in this document may not be supported Refer to the Release Notes shipped with the DFE module to determine which features are suppor...

Страница 22: ...rvices and management Self learning configuration modules with increased reliability and fault tolerance that reduces configuration time and maximizes uptime Network wide configuration change and inve...

Страница 23: ...al external Matrix N POE Power System The Matrix N POE Power System can provide 48 Vdc to support up to eight PoE compliant DFE modules The connection from the N POE Power System is by way of the 48 V...

Страница 24: ...ED 10 48 Vdc 20 Amperes Maximum optional power input connector 5 POE LED 11 Ports 1 48 10 100 Mbps through RJ45 connectors 6 GROUP SELECT button 1X G R O U P 1 G R O U P 2 11X 13X 23X OFFLINE RESET CO...

Страница 25: ...inal emulator Switch Configuration Using WebView Enterasys Networks HTTP based Web management application WebView is an intuitive web tool for simple management tasks Switch Configuration Using CLI Co...

Страница 26: ...s are used to assign Network Services to groups of users who share common needs for example Executive Managers Human Resources Personnel or Guest Users Access resources and security restrictions are a...

Страница 27: ...it allows for automatic configuration with manual overrides if applicable and can operate on 10 Mbps 100 Mbps or 1000 Mbps Ethernet full duplex ports Thus the network administrator can combine a grou...

Страница 28: ...formation about PoE refer to Appendix C 100BASE TX Network The fixed front panel ports of the 4H4285 49 provide a connection that supports Category 5 UTP cabling The device at the other end of the twi...

Страница 29: ...lationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden Important Notice Read the Release Notes shipped with the DFE module to check for any exceptions to the supported...

Страница 30: ...ct Enterasys Networks if there are any signs of damage Refer to Getting Help on page xviii for details Warning Install this module in a Matrix N3 or N7 chassis that has been installed in a Restricted...

Страница 31: ...acement rules Matrix N3 Matrix N5 or Matrix N7 chassis The Matrix N3 Matrix N5 or Matrix N7 chassis support only DFE modules and there are no particular rules for installing modules Note Install any o...

Страница 32: ...be due to module reset removal or failure However with the redundancy key installed the system will remain operational provided that there is an operating module in slot 1 or 2 Figure 3 1 Examples Slo...

Страница 33: ...system completely as long as there is an operating module in slot 1 or 2 Example 4 Figure 3 1 D Shows a chassis populated with 4xxxxx modules in all slots except 1 and 2 This system is not operationa...

Страница 34: ...sis on page 3 10 Caution Failure to observe static safety precautions could cause damage to the DFE Gold module Follow static safety handling rules and wear the antistatic wrist strap Do not cut the n...

Страница 35: ...de panel posterior Aseg rese de que la palanca superior est alineada con respecto al n mero de ranura correspondiente ubicado en el panel frontal del chasis Electrical Hazard To prevent exposure to a...

Страница 36: ...turn the power supplies on Check to see that the module CPU LED settles at solid green after a few minutes If the LED does not turn solid green refer to Chapter 4 for troubleshooting details Caution I...

Страница 37: ...d 7 Backplane connectors power and FTM2 4 Metal back panel 1 SERIES E7 4 5 6 7 2 3 50 60Hz LINE 100 125V 12A 200 240V 6A 50 60Hz LINE 100 125V 12A 200 240V 6A ACON 1 0 POWER FAN PS1 50 60Hz LINE 100 1...

Страница 38: ...s stos podr an da arse Warning Install this module in a Matrix N3 or N5 chassis that has been installed in a Restricted Access Location only Access to the equipment by users must be restricted through...

Страница 39: ...tz vor el Sch den des Moduls 4H4285 49 zu gew hleisten bei Verwendung der N POE Systeme sollte dies bevor man dieses entnimmt oder Servicearbeiten daran vornimmt vom 48 Vdc Stecker getrennt werden Fig...

Страница 40: ...m Advertencia El modulo DFE es embarcado con una cubierta sobre su conector de poder opcional de 48 Vdc No remover esta cubierta cuando el modulo DFE es instalado en un chassis N5 Esta cubierta debe r...

Страница 41: ...owered devices that require 48 Vdc through the UTP cable to operate Whether the 48 Vdc is available through the backplane of an N5 chassis or externally from an N POE Power System you can verify if th...

Страница 42: ...utton for less than one second see Figure 3 4 to step to the group of interest Groups 1 through 4 b Each time the GROUP SELECT button is pressed for less that one second the GROUP LED lights up in seq...

Страница 43: ...segment have the proper pinouts and check the cable for continuity Typically a crossover cable is used between hub devices A straight through cable is used to connect between switches or hub devices...

Страница 44: ...ugh cable 2 Other device port 4 RX RX and TX TX connections These connections must share a common color pair Figure 3 7 Eight Wire Crossover Cable RJ45 Pinouts Connections Between Hub Devices 1 RJ45 d...

Страница 45: ...85 49 RJ45 port ensure that there is power at the RJ45 port as follows 1 Press on the GROUP SELECT button for more than one second The 4H4285 49 will enter the PoE status mode which will indicate a se...

Страница 46: ...er you can connect products equipped with an RJ45 COM port to an IBM or compatible PC running a VT series emulation software package With a UTP straight through cable and RJ45 to DB25 female adapter y...

Страница 47: ...a VT Series Terminal To connect a VT Series terminal to an Enterasys Networks DFE module COM port Figure 3 10 use a UTP straight through cable with RJ45 connectors and an RJ45 to DB25 female adapter...

Страница 48: ...access the Setup Directory Set the following parameters on your terminal When these parameters are set the Local Management password screen will display Refer to the Enterasys Matrix DFE Gold Series C...

Страница 49: ...connector at the other end of the UTP straight through cable into the RJ45 to DB25 modem adapter 3 Connect the RJ45 to DB25 adapter to the communications port on the modem 4 Turn on the modem 5 With...

Страница 50: ...Figure 3 11 Connecting Using a Modem 1 UTP straight through cable with RJ45 connectors 4 Local modem 2 RJ45 COM port 5 Remote modem 3 RJ45 to DB25 modem adapter 6 PC 1X G R O U P 1 OFFLINE RESET COM C...

Страница 51: ...RX 4 Red 3 Transmit TX 5 Green 5 Ground GRD 2 Orange 7 Request to Send RTS 6 Yellow 8 Clear to Send CTS VT Series Port Adapter Wiring and Signal Diagram RJ45 DB25 Pin Conductor Pin Signal 4 Red 2 Tran...

Страница 52: ...es will automatically be set to the factory default values A complete list of the factory default values are provided in Chapter 3 of the Enterasys Matrix DFE Gold Series Configuration Guide After ins...

Страница 53: ...bout setting the IP address and configuring Telnet settings for remote access to DFE module management refer to Chapter 3 in the Enterasys Matrix DFE Gold Series Configuration Guide The CLI commands e...

Страница 54: ...accordingly If you need to change any settings you can connect a terminal to the local console port as described in Connecting to COM Port for Local Management on page 3 18 to access system managemen...

Страница 55: ...apter 3 in the Enterasys Matrix DFE Gold Series Configuration Guide The CLI commands enable you to initially set up and perform more involved management configurations The Enterasys Matrix DFE Gold Se...

Страница 56: ...Completing the Installation 3 28 Installation...

Страница 57: ...agement functions for all DFE Gold modules in the chassis The Management Module handles all IP requests to the chassis IP address such as PING Telnet SNMP HTTP and more The Management Module also hand...

Страница 58: ...GROUP SELECT button see Figure 4 1 to step to the group of interest Groups 1 through 4 Each time the GROUP SELECT button is pressed the GROUP LED lights up in sequence indicating which group is select...

Страница 59: ...gment If there is power at the port the RX LED is green and the TX LED is off Otherwise refer to Table 4 1 for troubleshooting information 3 Press the GROUP SELECT button again for more than two secon...

Страница 60: ...s that the module is in the process of shutting down None This state is activated when the OFFLINE RESET switch is pressed for less than 1 second to start the process of an orderly shutdown While in t...

Страница 61: ...llisions This indication is only supported on 10 100 ports Contact Enterasys Networks for technical support TX Transmit Off Port enabled but no activity If it is known that the port should be active a...

Страница 62: ...asys Networks for technical support Red Off Port is off due to PoE power management Port may be turned off due to priority or other administration configuration None Off Off Port is off for other reas...

Страница 63: ...clear NVRAM Cannot navigate beyond Password screen Improper username password combination entered If the username password combination has been forgotten refer to Refer to Setting the Mode Switches o...

Страница 64: ...the front panel OFFLINE RESET switch was pressed Position of Mode switch 7 Persistent Data Reset was changed sometime before either cycling power or pressing the OFFLINE RESET switch causing the user...

Страница 65: ...ligent decisions and stabilize the network before the change is made thereby increasing network availability You can shut down a DFE module in an operating system using the OFFLINE RESET switch shown...

Страница 66: ...E RESET switch for approximately 6 seconds Pulling any DFE module out of the chassis before it has been shut down is not recommended The only safe time to pull a module out of the chassis is after the...

Страница 67: ...ory physical and environmental module specifications for DFE Gold module 4H4285 49 For information about Refer to page 4H4285 49 Specifications A 1 COM Port Pinout Assignments A 3 Regulatory Complianc...

Страница 68: ...2 38 W x 11 62 D in Approximate Weight Gross 5 54 kg 12 0 lb shipping carton containing one module Net 4 10 kg 9 0 lb one module without packaging Predicted hours for Mean Time Between Failures MTBF F...

Страница 69: ...Table A 3 Table A 2 COM Port Pin Assignments Pin Signal Name Input Output 1 Transmit Data XMT Output 2 Clear to Send CTS Input 3 Data Set Ready DSR Input 4 Receive Data RCV Input 5 Signal Ground GND N...

Страница 70: ...Regulatory Compliance A 4 Specifications...

Страница 71: ...r to page Required Tools B 1 Setting the Mode Switches B 2 Memory Locations and Replacement Procedures B 3 Gaining Access to Memory Modules B 4 Caution An antistatic wrist strap is required to perform...

Страница 72: ...r use the factory default settings or reenter your own parameters Switch 8 Clear Admin Password Changing the position of this switch clears the admin password and restores the factory default password...

Страница 73: ...e memory modules If you have questions concerning the replacement of either memory module refer to Getting Help on page xviii for details on how to contact Enterasys Networks Figure B 2 shows the DIMM...

Страница 74: ...48V 20A MAX OPTIONAL POWER INPUT 4H4285 49 FAST ENET DFE 1 2 3 4 5 6 1 2 3 4 5 6 7G 6MGBIC A Electrical Hazard To prevent exposure to an energy hazard in a 4H4285 49 connected to an external N POE Po...

Страница 75: ...cover 4 If you are replacing the DRAM SIMM proceed to DRAM SIMM Replacement Procedure on page B 7 If you need to replace the DIMM proceed to DIMM Replacement Procedure on page B 10 Warning The safety...

Страница 76: ...crews 7 4 Standoff spacer screwed to standoff under the interface board 1X G R O U P 1 G R O U P 2 11X 13X 23X OFFLINE RESET COM CPU MGMT GROUP SELECT GROUP 1 2 3 4 5 6 7 8 9 10 11 12 POE 12 X 14X 24X...

Страница 77: ...the Optional Network Expansion Module Caution Observe all Electrostatic Discharge ESD precautions when handling sensitive electronic equipment Precauci n Al trabajar con equipos electr nicos sensible...

Страница 78: ...ors Now you have access to the DRAM SIMM To replace the DRAM SIMM proceed to Removing the DRAM SIMM Removing the DRAM SIMM To remove the DRAM SIMM refer to Figure B 5 and proceed as follows 1 Refer to...

Страница 79: ...or until the two alignment notches and the tabs on the two connector arms lock the DRAM SIMM into place 3 Reinstall the NEM Refer to Reinstalling the Optional Network Expansion Module on page B 12 for...

Страница 80: ...o the standoffs on the main PC board 2 Locate the DIMM connector on the main PC board Refer back to Figure B 2 for the DIMM location on the 4H4285 49 3 Push the connector arms away from the DIMM as sh...

Страница 81: ...outward push the DIMM down between the connector arms Then release the two connector arms to lock the DIMM into place 3 Reinstall the safety cover Refer to Reinstalling the Safety Cover on page B 13...

Страница 82: ...saved coverplate screws to fasten the NEM to the DFE Gold module front panel but do not tighten screws at this time 4 Insert the saved standoff through the NEM to the standoff on the main board Screw...

Страница 83: ...This completes the safety cover installation Warning The safety cover protects you from exposure to an energy hazard in excess of 240 Volt Amperes Never operate the DFE module without the safety cove...

Страница 84: ...1 Safety cover 2 Screws 7 3 Standoff 7 1X G R O U P 1 G R O U P 2 11X 13X 23X OFFLINE RESET COM CPU MGMT GROUP SELECT GROUP 1 2 3 4 5 6 7 8 9 10 11 12 POE 12 X 14X 24X G R O U P 3 25X 35X 26X 36X G R...

Страница 85: ...s the power supply current and the other pair provides a path for the return current While several proprietary legacy implementations of PoE have been deployed by LAN equipment vendors in 2003 the IEE...

Страница 86: ...he status signals indicate the presence and operating state of each power supply module in the N POE Power System This 48 Vdc Optional Power Input interface is not fused as the N PoE Power System has...

Страница 87: ...from the default RX TX Status Mode to the PoE Port Status Mode using the DFE module front panel GROUP SELECT button The switch operation and a description of how to use the LED indications are descri...

Страница 88: ...PoE Port Status LEDs C 4 About PoE Power over Ethernet...

Страница 89: ...B 3 E Electromagnetic Compatibility EMC requirements A 3 F Front panel UTP connections 3 13 G GROUP SELECT button use of the 4 2 4 3 I Installation connecting to the network 3 12 module into Matrix E7...

Страница 90: ...Related manuals obtaining xvi Required Tools B 1 Required tools B 1 RESET button See OFFLINE RESET button S Safety Cover installation of B 13 removal to access memory B 5 Safety requirements A 3 Speci...

Отзывы: