NO. NX2010597/ NO. 72983_C
06/04/2021
27 (35)
4P
R
-F
14
-D
Stopping the indication
The illuminated indication is stopped:
Automatically after two hours
On restoration of MV for a time longer than 5 s
By deliberately pressing PB2: Reset button
Actuating reset: Stops the indicators and opens the remote control output contacts
FAULT COUNTER
The counter is used to store validated transient type faults (elimination of the fault by resetting
sequences on the source unit).
It has a 4-digit LCD display.
The three counters (green, red, and polyphase) are displayed alternatively for 1 s (total duration).
The value “xxxx” displayed by a counter runs from 0000 to 9999.
To launch the display procedure, press the “counter display” button (PB3).
The display sequence is as follows:
1 s “POLY”
1 s “xxx”: polyphase counter
1 s “RED”
1 s “xxx”: red counter
1 s “GREEN”
1 s “xxx”: green counter
The three counters can be simultaneously reset by pressing the counter display button (PB3) for 3 s (you
should see “0” on the display).
4.2.
Controls, tests, configurations - upgrades with new functions
Controls
The user interface (UI) has:
Pushbutton controls:
A TEST button: press this button to run a test
A TEST RESET button: this button has two functions:
o
Pressing for less than 3 seconds stops the test or resets the fault in progress
o
Pressing for longer than 3 seconds starts a detector calibration procedure
A DISPLAY button: this button has two functions:
o
Pressing for less than 3 seconds displays the counters on the screen
o
Pressing for longer than 3 seconds resets the value of all the counters
A µC RESET button: press this button to validate the inverter position reading (you must validate
all inverter position changes by pressing this button)