5.8 EVF300 mounting on concrete foundation
Items needed:
Mounting box EVTL35.00
1 pcs
Adapter for concrete foundation EVTL37.00
1 pcs
Concrete
foundation
1
pcs
This example describes installation procedure using concrete foundation, product code SJR-08, supplied by
Sähkö-Jokinen Oy.
I
f you want to use a foundation manufactured by another supplier, make sure that the foundation is compatible
with the adapter.
•
Dig a pit for the concrete foundation. The pit floor should be trampled and horizontal.
•
Install the foundation, cable pipes (supply and output chaining) and, if necessary, the cable pipe for the
data cable into the ground. The pit floor should be trampled and horizontal.
•
Fill the pit with gravel. Trample the filling around the foundation to ensure stability.
800
450
Ground
Gravel
Adapter
EVTL37.00
Concrete
foundation
Cable protection pipe Ø110