5
RAK78 /
©
Ensto 2018
Parameter
Installer menu
No
Name Parameter description
Factory setting
Alternative
setting
01
SEnS
Sensor selection
Sens
Air Only
Internal sensor
Sens
Flor Only
External sensor
02
CAL
Air
Calibrate internal sensor
Procedure: Before calibration, operate the thermo-
stat with same temperature setting for at least one
day. Put a thermometer at the same height as the
thermostat (approx. 1.5 m above the floor) and give
it enough time to stabilize. Press the joystick and
enter the value that is read out from the thermom-
eter. Save by pressing the joystick.
Note! The heating element managed by the thermo-
stat must be in operation during the calibration.
no
Not calibrated
done
Calibrated
03
CAL
SoL
Calibrate external sensor**.
Procedure: Before calibration, operate the ther-
mostat with same temperature setting for at least
one day. If the external sensor is used as floor
sensor, put the thermometer on the floor and give
it enough time to stabilize. Press the joystick and
enter the value that is read out from the thermom-
eter. Save by pressing the joystick.
Note! The heating element managed by the thermo-
stat must be in operation during the calibration.
no
Not calibrated
done
Calibrated
04
1rst
Heat
Drying function for concrete floors.
When activated, this function starts a drying pro-
gram that lasts for 21 days. During the first 24 hours
the heating is on 2 hours totally. For each follow-
ing day, another 1 hour of heating is added. The
temperature is limited to 20 ⁰C during the program.
The function is not stopped due to possible power
breaks.
no
Not activated
21
Activated
05
LoAd
Connected load [W].
Do not connect a load that exceeds 2300 W to the
thermostat.
1500
Adjustable
0
to
2300
in steps of 50
09
End
Exit the installation menu.
The program version is displayed.
Press the joystick.
E750 X.xx
Содержание ECO10LCDJR