ENSIM SENSORS ELP Скачать руководство пользователя страница 7

1.8. Label Information

Mark

Serial No

Model Type

Type
Max Press.
Max Temp.
Max Current

:
:
:
:

ELP 81s
10 bar
80°C
0,5A  SN: 150689-05

Output

Serial No

Specifications

Flow Direction

Model Type

1.5. Target Group

This operating manual has been prepared for qualified technical personnel.

1.6. Security Notes

Following notes should be taken into consideration in order to avoid dangers which can occur on the operator and around

the ambient:
Installation, operation and maintenance of this instrument should be made only by people who have read the operating manual and
who are knowledgeable about work safety!
It should be complied with work safety, accident prevention regulations and national installation standards.
Product should be used only within the scope of stated specifications!
You can assemble the instrument only when pressure is not available!

1.7. Content of Package

Please check whether you have taken delivery of below listed content completely or not and check its conformity with
criterions in your order:
*Level switch
* Allen key ( for 81p ELP )
*This operating manual

7

Single Contact NO

ELP 81p

Float Material
Wetted Parts Material
Pipe Material
Float Type
Working Temperature
Mechanical Connection
Max. Pressure (Bar)
Min. Density (g/cm3)
Electrical Connection
Number of Float
Number of Contact

*Max. Contact Power
*Max.Switching Voltage

*Contact Current

PP
PP
PP

P81

(-) 20 °C / (+) 80 °C

3/4" BSP

10 bar

0.75 (g/cm³)

DIN43650C Socket

1 Std.

1 x SPST x NO

1  A

10 W / VA

200 VDC / 140 VAC

150

58

3/4” BSP

125

ELP 81p

Closed

Technical Specifications :

Содержание ELP

Страница 1: ...ch User is responsible for accidents and losses arising from failure to comply with the warnings in this manual In the event that level switch is broken take measures in order to prevent accidents and...

Страница 2: ...ELP level switches are used for checkin level of tank It is preferred by machine manufacturers especially in terms of its ease ofg use and economy The ELP level switched can be mounted in litte place...

Страница 3: ...NO Float Material Wetted Parts Material Pipe Material Working Temperature Max Pressure bar Min Density g cm3 Electrical Connection Number of Float Number of Contact 180 VDC 130 VAC 10 W VA Max Contac...

Страница 4: ...C 1 2 NPT 4 bar 0 65 g cm Cable 1 Std 1 x SPST NO 1 A 10 W VA 200 VDC 140 VAC 107 5 79 5 10 20 2 1 2 NPT 7 17 5 4 5 O ELP 31L ELP 33L Black Blue Single Contact NO Black Blue Single Contact NO Float M...

Страница 5: ...Temperature Mechanical Connection Max Pressure Min Density Electrical Connection Number of Float Number of Contact Max Contact Power Max Switching Voltage Contact Current PP PP P10 20 C 80 C 1 BSP 4...

Страница 6: ...x y z MODEL ELP 26 25 10 8 40 55 6 16AA 15AA M10 x 1 55 mm d c e 30 a y f x b ELP 26 f z Dimension Cylindric c e d a b y x ELP 81 ELP 82 a b c d e f x y z MODEL ELP 81 44 50 14 152 200 34 44 34AA R 1...

Страница 7: ...ations and national installation standards Product should be used only within the scope of stated specifications You can assemble the instrument only when pressure is not available 1 7 Content of Pack...

Страница 8: ...xplanations according to structure of the design 2 3 Special Notes Please ensure that there is no mechanical stress on the shaft following installation Such case will cause slipping in thecharacterist...

Страница 9: ...ded to be used as follows depending on used voltage for the purpose of protection of switch Capacitive Load Inductive Load Inductive Load Inductive Load Neon Lamp 2 5 Reed Relay and Protection Circuit...

Страница 10: ...VAC 8 A ESR 220 Special x Vertical Type 18 mm L 20 mm Open at Bottom 02a Vertical Type 18 mm L 20 mm Closed at Bottom 02b Vertical Type 19 mm L 31 mm Open at Bottom 03a Vertical Type 19 mm L 31 mm Cl...

Страница 11: ...ay cause Please keep away from magnetic field otherwise it might be mis operated Please do not drop otherwise the characteristics might be changed Vibration might be caused instability In case vapour...

Страница 12: ...roken Furthermore you should also add a detailed explanation which describes the breakdown while instrument is sent If your instrument contacts with harmful substances decontamination report should be...

Отзывы: