Mechanic Connections :

Flanged

b

D1

D

Hex

B

b

Thread

Clamp

b

D

Dairy

d

d1

D

A

Material : 

304 Stainless Steel

Welded manufacturing
Opens - Closes Hinged
To Protect Against external conditions.

Protection  Case :

Housing :

MATERIAL

PROTECTION

CLASS

TEMPERATURE

(

o

C)

TYPE

B20x

Aluminium

IP 66

-40...+200

SIZE

a x b  (mm)

132 x 104

ORDER

CODE

25

Cooling :

27 Hex

PFA

L

68

For 200°C

1/2”BSP

B20x

Alüminium

b

a

Ta

Factory Area

(Safe)

ZONE 21 / 1

or

ZONE 22 / 2

Tp

Process Side

(Explosive Enviroment)

ZONE 20 / 0

or

ZONE 21 / 1

or

ZONE 22 / 2

Order

Code

Dimension

B

Hex

[mm]

Stem Lenght

b [mm]

3/8”BSP
1/2”BSP
3/4”BSP

1”BSP

1 1/4”BSP
1 1/2”BSP

2”BSP

50
50
50
50
50
60
70

20
14
14
23
23
23
23

(ISO228-1)

003
004
005
006
007
008
009

PN 16

D (mm)

DN25
DN32
DN50
DN80
DN100

165
140
165
200
220

85

100
125
160
180

D1 (mm) b (mm)

16
16
18
20
20

(ISO1092-1)

Order

Code

103
104
106
108
109

PN 40

D (mm)

DN25
DN32
DN50
DN80
DN100

115
140
165
200
235

85

100
125
160
190

(ISO1092-1)

D1 (mm) b (mm)

18
20
20
20
24

Order

Code

303
304
306
308
309

150 LBS

D (mm)

DN50
DN65
DN80
DN100

152,4
177,8
190,5
228,6

121

139,7
152,4
157,2

(ANSI B16.5)

D1 (mm) b (mm)

19

22,2
23,8
23,8

Order

Code

606
607
608
609

Dimension

Dia.

b

(mm)

DN32
DN50
DN65

50,5

64
91

15
17
17

(ISO2852)

D (mm)

851
852
853

Order

Code

D (mm)

DN40
DN50
DN100

56
68

121

48
61

114

d1 (mm) A (mm)

13
14
20

Dimension

DN40
DN50
DN100

Dimension

870
871
872

Order

Code

Содержание DX-ECAS 101

Страница 1: ...ive level switch User is responsible for accidents and losses arising from failure to comply with the warnings in this manual In the event that Capasitive level switch is broken take measures in order...

Страница 2: ...liquids Grain stores cement sand feed flour milk powder organic and plastic granule Sticky hot and high viscosity liquid acid and chemical liquids Ambient Conditions Relative Humidity 0 98 RH Ambient...

Страница 3: ...transfer in our capacitive sensors Total impedance is defined as Z V I I current I Q t Q Coulomb T sec Capacitive reactance we desire to measure is jC 1 Meaning that charge and impedance have the same...

Страница 4: ...1 6 With LED Power and Contact LED Max 1 W Terminal EMC Low Voltage 285 g for DX ECAS 101 20 60 C IP 66 Max 40 NM Max 500V Supply Signal Output Working Pressure Min Di Electric Constant Measurable Me...

Страница 5: ...e DX ECAS 101 9 250 1 008 11 01 67 02 00 0 Power Supply Output Process Temp T Ambient Serial Number Level Switch 24VDC 10 1 x 5A 250VAC NO NC 40 150 C 20 60 C IE18040002 0001 www ensim com tr MADE IN...

Страница 6: ...order not to affect the IP protection class Make sure the cable entry and plug is tightened right Ground connection must be done properly and checked without energizing Before starting use make sure...

Страница 7: ...ment Category Explosive Atmosphere Explosive Protection Protection Type Dust Type Temperature Class Max Surface Temperature Housing Protection Class Gas Explosive Atmosphere Protection Type Temperatur...

Страница 8: ...cording to structure of the design 2 3 Special Notes Please ensure that there is no mechanical stress on the shaft following installation Such case will cause slipping in thecharacteristic curve Capac...

Страница 9: ...High Level span value during calibration CAL Z Button Used to acquire Low Level zero value during calibration TST Button During normal operation functions as Relay Test during calibration performs sav...

Страница 10: ...BSP 3 4 BSP 1 BSP 1 1 4 BSP 1 1 2 BSP 2 BSP 50 50 50 50 50 60 70 20 14 14 23 23 23 23 ISO228 1 003 004 005 006 007 008 009 PN 16 D mm DN25 DN32 DN50 DN80 DN100 165 140 165 200 220 85 100 125 160 180 D...

Страница 11: ...Max 16 m DX ECAS 107 PFA 3 4 BSP 50 Hex L St St 80 St St 35 St St 1 1 2 BSP 60 Hex PFA L 80 200 St St St St 2 BSP 70 Hex 40 PFA L 80 Aluminium Aluminium Aluminium 1 25 bar 40 150 C DX ECAS 101 L 250mm...

Страница 12: ...DX ECAS 202 L 250mm Std Max 4 m 1 25 bar 40 150 C DX ECAS 203 L 250mm Std Max 1 m 1 25 bar 40 150 C 50 Hex L 3 4 BSP St St 70 Hex L 2 BSP St St Aluminium Aluminium DX ECAS 20S zolesiz Koaksiyel Prob l...

Страница 13: ...ax 6 m 1 25 bar 40 150 C St St Antistatic For Materials DX ECAS 304 L 1000mm Std Max 16 m 1 25 bar 40 150 C L 380mm Std Max 1 m 1 25 bar 40 200 C DX ECAS 30D Double Partly Insulated Probe Insulating T...

Страница 14: ...1 25 bar 40 150 C L 50 Hex 1 BSP St St PTFE St St Aluminium ECAS 408A Double Probe Single Fully Insulated Conductive Insulating Tank L 250mm Std Max 4 m 1 25 bar 40 150 C L 50 Hex 1 BSP PFA St St Alu...

Страница 15: ...5 C 200 C 200 C 200 C 200 C 20 C T Ambient 30 C 60 C Working Temperature 20 200 C DX ECAS Metal With Cooling 30 C 40 C 50 C 60 C 42 C 46 C 56 C 68 C T6 T6 T6 T6 T6 T6 T6 T5 2 9 Maximum Surface Tempera...

Страница 16: ...l Grounding Label Body Set screw Grounding Screw Grounding Internal Bracket Stopper Cable Record Metal Label Body Seal Grounding Screw Grounding Outer Bracket Connection Thread Cover Set screw Probe I...

Страница 17: ...DX ECAS 101 10 300 0 006 11 25 66 02 00 0 For Cond Liquid L 300mm 1 BSP Relay Output Aluminium Housing 10 Probe Thread ISO 228 1 Clamp ISO 2852 ISO Flange 1092 1 ASA Flange B16 5 Special Flange 1 2 BS...

Страница 18: ...roblem may cause Do not fasten switch reversely otherwise its characteristics might be changed Please do not drop otherwise the characteristics might be changed Vibration might be caused instability D...

Страница 19: ...y modification on the instrument 10 Terms of Return In the return of materials user should send an open list related to damage or problem malfunction of the material to be returned or its operation in...

Отзывы: