MODULE CONFIGURATION AND CONTROL
The configuration parameters for each Avenue module must be selected after installation.
This can be done remotely using one of the Avenue remote control options or locally using
the module front panel controls. Each module has a
Remote/Local
switch on the front
edge of the circuit board which must first be set to the desired control mode.
The configuration parameter choices for the module will differ between
Remote
and
Local
modes. In
Remote
mode, the choices are made through software and allow more
selections. The
7500 Parameter Table
later in this section summarizes and compares
the various configuration parameters that can be set remotely or locally and the
default/factory settings. It also provides the default User Levels for each control. These
levels can be changed using the Avenue PC application
If you are not using a remote control option, the module parameters must be configured
from the front panel switches. Parameters that have no front panel control will be set to a
default value. The
Local
switches are illustrated in the
Front Panel Controls and
Indicators
section following the
7500 Parameter Table
. The
Local
switches are
inactive when the
Remote/Local
switch is in the
Remote
position.
In the
Remote
mode, Avenue module parameters can be configured and controlled from
one or both of the remote control options, the Avenue Touch Screen or the Avenue PC
Application. Once the module parameters have been set remotely, the information is
stored on the module CPU. This allows the module to be moved to a different cell in the
frame at your discretion without losing the stored information.
For setting the parameters remotely using the Avenue PC option, refer to the
Avenue PC
Remote Configuration
section of this document.
For setting the parameters remotely using the Avenue Touch Screen option, refer to the
Avenue Touch Screen Remote Configuration
section of this document following
Avenue PC.
For setting the parameters remotely using the Avenue Express Control Panel option, refer
to the
Avenue Express Control Panel
data pack that comes with the panel option.
Configuration Summary
This section provides a general overview of the configuration for the 7500 module. The
controls available for configuration with remote control are summarized and tips and
examples are given for using particular controls to achieve the best results.
Video Processing
The 7500 has a full-featured Proc Amp for adjustment of every signal parameter. Proc
controls adjust the overall video signal. A color processor menu allows for targeting a
specific hue you may wish to change, then adjusting color processing parameters for the
targeted hue without affecting other colors in the scene.. A Legalizer menu allows adjust-
ment of black and white clips to prevent excessive signal excursions or the output can be
set to meet default RGB values determined on a pixel by pixel basis.
7500-7
Model 7500 HD Video Proc Frame Sync
Содержание Avenue 7500