ORDER NR
:
19121
Rev. x Date. x-xx-xxxx
Name: GLI
30
7.2
Maintenance list
Table 8-2a
Maintenance table every 250 hrs.
Interval:
Component:
Maintenance
Description
Remarks:
Every 250
hours:
O
2
-analyser (5300)
Check ‘zero’ and
‘span” calibration
or renew (average
every 4 years)
Opsis manual
Differential pressure indication on top
of the coalescing filters
If red than renew
Zander manual.
Automatic drain valves
Test - clean drain
lines (if necessary)
Bekomat manuals
Table 8-2b
Maintenance table 1500 running hours.
Interval:
Component:
Maintenance
Description
Remarks:
Every 1200
running
hours
Pre- / micro filter elements
Renew
Zander manual
Activated carbon
Renew
750 kg
REMARK:
After renewing activated carbon, first close membrane inlet valves (3020) and
override solenoid 2730 at the slow-opening valve 2700 manually, by rotating the override
screw.
Start 1 of the compressors, pressurise the carbon bed and wait until the compressor switch
to off-load operation.