background image

|

User’s Guide 

|

Purelight 

UV Light Wand

Содержание Purelight Series

Страница 1: ... User s Guide Purelight UV Light Wand ...

Страница 2: ...designed to help reduce and control disease causing bacteria viruses and fungi in your living environment We hope you enjoy using this innovative product and the peace of mind that comes with it User Guide Read all instructions carefully before use 2 UV Light Wand UV Band Pass Filter XD 2D04 Aluminium Filter ED 3000 UV C Lamp Power Adapter ...

Страница 3: ... invisible light without any harmful chemical agents 2 No chemical residue and moderate UV exposure doesn t damage the materials 3 Helps to eliminate bacteria viruses fungi moulds etc when used in houses hospitals dentistry nursing homes and more 4 Lightweight convenient hand held design 5 LED display lets you know when the device is operating 6 Easy to use 7 Safety features a Special UV filter gi...

Страница 4: ...l shut off automatically B Safety Mode Operation 5 minute Indicator 1 Note that when the switch is pushed once it will make a beep sound but the UV lamp is still not on 2 To enter Safety Mode 5 minutes rapidly press the switch twice After successfully pressing the switch there will be a beep sound and 05 light plus the green Lamp light at the top left hand corner of the indicator panel will come o...

Страница 5: ... 10 seconds 3 To SHUT OFF the unit simply push the switch once 4 At all times the green LED Lamp signal light indicates the UV lamp is ON Please maintain plug in when you operate overan hour E How to charge 1 Charging starts by plugging in the adapter into an outlet 2 Purelight operates for 60 minutes by charging for 3 hours 3 Be sure to charge once every two months 4 When not in use for a long pe...

Страница 6: ...es more frequently the soles of shoes are the major source of bringing bacteria into the home 9 Computers Doorknobs Telephones etc Expose at a distance of 2inches 5 cm for 10 seconds 10 When in doubt effective disinfecting can generally be achieved in 20 seconds at a distance of about 2 inches 5 cm Guidelines for Hospital Clinic Dental Office 1 Scanning Purelight slowly on any area where patients ...

Страница 7: ...use by the end user In no event shall Enputech Co Ltd be responsible to the end user for any incidental or consequential damage where foreseeable or not including but not limited to property damage inability to use equipment lost business lost profits or inconvenience arising out of or connected with the use of instruments produced by Enputech Co Ltd Enputech Co Ltd is not liable or responsible fo...

Страница 8: ...F 422 Sangdaewon Dong Joongwon Gu Seongnam Si Gyeonggi Do Republic of Korea 462 120 Tel 82 31 744 4549 Fax 82 31 744 4552 E Mail hyjo enputech com Consumer Service 345 DOUGHTY BLVD INWOOD NY 11096 Tel 516 284 6799 E mail ran n3acorp com ...