background image

Enphase Customer Support:

 enphase.com/en-us/support/contact

Safety and Advisory Symbols

+

DANGER

: This indicates a hazardous situation, which if not avoided, will 

result in death or serious injury.

*

WARNING

: This indicates a situation where failure to follow instructions 

may be a safety hazard or cause equipment malfunction. Use extreme 

caution and follow instructions carefully.

NOTE

: This indicates information particularly important for optimal 

system operation. Follow instructions carefully.

Safety Instructions

+

DANGER

: Risk of electric shock. Risk of fire. Do not attempt to repair the 

IQ Gateway; it contains no user-serviceable parts. Tampering with the IQ 

Gateway will void the warranty. If the IQ Gateway fails, contact Enphase 

Customer Support for assistance (enphase.com/en-us/support/contact). 

+

DANGER: 

Risk of electrocution! Do not install CTs when current flowing 

in the sensed circuit. Always install CT wires in the terminal blocks before 

energizing the sensed circuit.

+

DANGER

: Risk of electric shock. Do not use Enphase equipment in a 

manner not specified by the manufacturer. Doing so may cause death or 

injury to persons, or damage to equipment. 

+

DANGER

: Risk of electric shock. Be aware that installation of this equip-

ment includes risk of electric shock. Do not install the IQ Combiner 4/4C 

without first removing AC power from the Enphase System. Ensure the 

power coming from the microinverters is de-energized before servicing 

or installing.

+

DANGER

: Risk of electric shock. Risk of fire. Only qualified personnel 

should troubleshoot, install, or replace the IQ Combiner 4C or IQ Com-

biner 4.

+

DANGER

: Risk of electric shock. Improper servicing of the IQ Combiner 

4C or IQ Combiner 4 or its components may result in a risk of shock, fire 

or explosion. To reduce these risks, disconnect all wiring before attempt-

ing any maintenance or cleaning.

+

DANGER

: Risk of electric shock. Always de-energize the AC branch circuit 

before servicing. While connectors are rated for disconnect under load, it 

is a best practice to de-energize before disconnecting. 

+

DANGER

: Risk of electric shock. Risk of fire. Only use electrical system 

components approved for wet locations.

+

DANGER

: Risk of electric shock. Risk of fire. Ensure that all wiring is 

correct and that none of the wires are pinched or damaged. 

+

DANGER

: Risk of electric shock. Risk of fire. Do not work alone. Someone 

should be in the range of your voice or close enough to come to your aid 

when you work with or near electrical equipment. Remove rings, brace-

lets, necklaces, watches etc. when working with batteries, photovoltaic 

modules or other electrical equipment.  

+

DANGER

: Risk of electric shock. Risk of fire. Before making any connec

-

tions verify that the circuit breaker(s) are in the off position. Double check 

all wiring before applying power.  

+

DANGER

: Risk of electric shock. Risk of fire. Do not wire unused termi

-

nals or terminal blocks on the IQ Gateway.

+

WARNING: 

Risk of electric shock. To maintain the warranty,  

do not modify the dead-front other than to remove filler plates, as 

needed. 

*

WARNING

: Before installing or using the IQ Combiner 4C or IQ Combiner 

4, read all instructions and cautionary markings in the technical descrip-

tion and on the equipment.

*

WARNING

: Use the circuit breakers in the Enphase IQ Combiner 4C or 

IQ Combiner 4 only for serving Enphase equipment. No other loads are 

allowed.

FCC Statement

: This equipment has been tested and found to comply with the 

limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference in a 

residential installation. 

This equipment generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful interfer-

ence to radio communications. However, there is no guarantee that interference will 

not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, you are encouraged 

to try to correct the interference by one or more of the following measures:

  - Reorient or relocate the receiving antenna.

  - Increase the separation between the equipment and the receiver.

  - Connect the equipment into an outlet on a circuit different from that  

     to which the receiver is connected.

  - Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for com

-

pliance may void the user’s authority to operate the equipment.

This Class B digital apparatus complies with Industry Canada ICES-003.

*

WARNING

: This unit is not provided with a GFDI device. This inverter or 

charge controller must be used with an external GFDI device as required by 

the Article 690 of the National Electrical Code for the installation location. 

*

WARNING

: The IQ Combiner 4C and IQ Combiner 4 have a pre-installed 

heat shield attached to the enclosure door. Do not remove the heat 

shield.

*

WARNING

: This product is intended for operation in an environment 

having a maximum ambient temperature of 46ºC (115ºF).

*

WARNING

: BONDING BETWEEN CONDUIT CONNECTIONS IS NOT AUTO-

MATIC AND MUST BE PROVIDED AS PART OF THE INSTALLATION.

NOTE

: Perform all wiring in accordance with all applicable local electrical 

codes, with the Canadian Electrical Code, Part I, and with the National 

Electrical Code (NEC), ANSI/NFPA 70.

NOTE

: Protection against lightning and resulting voltage surge must be in 

accordance with local standards. 

NOTE

: Using unapproved attachments or accessories could result in 

damage or injury.

NOTE

: Install the IQ Combiner 4C or IQ Combiner 4 in the field with 75°C 

or higher copper conductors sized per local code requirements and 

voltage drop/rise considerations. 

NOTE

: Use Class 1 wiring methods for field wiring connections to terminals 

of a Class 2 circuit. Use 14 to 6 AWG wire for branch circuits and 14 to 3 

AWG for output circuits. Select the wire gauge used based on the protection 

provided by the circuit breaker(s)/fuses. Overcurrent protection must be 

installed as part of the system installation. 

NOTE

: To ensure optimal reliability and to meet warranty requirements, 

the Enphase IQ Combiner 4C and/or IQ Combiner 4 must be installed 

according to the instructions in this guide.

SAFETY (all models)

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Follow these important instructions during installation and maintenance of 

the IQ Combiner 4/4C. 

© 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ System 

Controller, IQ Battery, IQ Gateway, IQ Combiner, IQ Microinverter, Enphase Installer 

App, and other trademarks or service names are the trademarks of Enphase Energy, 

Inc. Data subject to change. 10-22-2021

Содержание IQ Combiner 4

Страница 1: ...icroinverters and or Enphase IQ Battery batteries To install the IQ Combiner 4 or 4C read and follow all warnings and instructions in this guide Safety warnings are listed on the back of this guide If you do not fully understand any of the concepts terminology or hazards outlined in these instructions refer installation to a qualified electrician or installer These instructions are not meant to be...

Страница 2: ...nd ground Large screw Small screw 14 1 0 AWG 14 6 AWG 5 0 Nm 45 in lb 2 2 Nm 20 in lb Main lug 10 4 AWG 3 2 0 AWG 5 0 Nm 45 in lb 5 6 Nm 50 in lb Copper conductors only rated minimum 75 C Follow NFPA 70 NEC or CSA C22 1 part 1 and all local codes For DG breakers larger than 20 A use wire insulated for 90 C based on 75 C ampacities The busbar supports a maximum of 90A of circuit breakers including ...

Страница 3: ...efore energizing the sensed circuit Load Center To Grid From IQ Combiner IQ Gateway Terminal Block Relay contacts if needed UP TO 250 Vac 100A 0 5V 45 66Hz white blue Not used white blue P1 C1 C2 1 2 3 4 NO Ref Common C Digital Input Relay PD B300 OVC II L1 L2 N CU 75C 14AWG MIN MEAS CAT III OVC III Production Consumption Consumption CTs The arrows must point toward the load away from the grid DAN...

Страница 4: ...e system details are added Step 1 and make sure that an appropriate grid profile is set for the system D Go to Devices Array Step 2 and add the total number of devices in the system Tap edit if you need to edit previously entered data E Input tarrif details in Step3 F Connect to the IQ Gateway with your mobile device smart phone or tablet The AP Mode LED lights solid green when the network is avai...

Страница 5: ...een for the following A For microinverters confirm that the expected number of devices are detected and communicating by navigating to Devices Array Microinverters Array and check that status is Producing B Check that the grid profile is set for all the microinverters Setting the profile may take up to 5 minutes for a typical system C To check if IQ Battery and or IQ System Controller are connecte...

Страница 6: ... Enphase Customer Support if you need to re install the modem at a different site Troubleshooting TROUBLESHOOTING Contact Enphase Customer Support enphase com en us support contact if you have any questions about troubleshooting your system a LED overview LED State Description All Flashing red in unison The IQ Gateway is booting up Flashing green sequentially Software upgrade in progress Network c...

Страница 7: ...failing or that is undersized may not generate enough power for AC conversion d Internet connection issues If you are using Wi Fi and the Network Communications LED remains off or solid red The WPS connection window may have timed out Retry the connection steps Make sure that the broadband router is connected and operational by checking that other devices at the site can access the network Check f...

Страница 8: ...g The operation is permitted for the following two conditions 1 the device may not cause harmful interference and 2 the user of the device must accept any interference suffered even if the interference is likely to jeopardize the operation Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions ...

Страница 9: ...iner 4 only for serving Enphase equipment No other loads are allowed FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency ener...