background image

  Q U I C K

  I N S T A L L  

G U I D E

 

PREPARATION

A )  Download the Enphase Installer App version 3.X mobile app and open it 

to log on to your Enphase App account. With this app, you can connect to 

the IQ Gateway to track system installation progress. To download, go to 

enphase.com/toolkit

.

B)  Check the box for the following items:

• 

Enphase IQ Combiner 4 or 4C with IQ Gateway printed circuit board. 

The X-IQ-AM1-240-4C also includes an LTE-M1 cell modem.

• 

A pair of split-core consumption metering CTs

• 

Enphase IQ Combiner 4/4C Quick Install Guide

 (this document)

C )  Make sure you have the following 

required

 items:

• 

An Ensemble Communications Kit (COMMS-KIT-01 ) is not included. It is required for 

all Ensemble installations and must be purchased separately. (only for installations 

with IQ battery or IQ System Controller)

•  Tools: screwdriver, pliers, and torque wrench.

•  Up to four Eaton BR-style breakers (one for each PV branch circuit). Eaton BR-style 

breakers are the only breakers you can use. You can install 10A, 15A, 20A, 30A, 40A, 

50A, or 60A breaker(s) in the IQ Combiner  (order Enphase BRK-10A-2-240V, BRK-

15A-2-240V, BRK-20A-2P-240V, Eaton BR210, Eaton BR215, Eaton BR220, Eaton 

BR230, Eaton BR240, Eaton BR250, and/or Eaton BR260 circuit breakers). The sum 

of all Distributed Energy Resources (DER) branch breaker ratings cannot exceed 80 

A. For IQ8 systems with IQ System Controller, use BRK-15A-2P-240-B for 15A cir-

cuits and BRK-20A-2P-240-B for 20A circuits to be compatible with the hold down 

kit. You can also use Eaton BR215B and Eaton BR220B breakers for IQ8 systems. 

The IQ Gateway breaker should not exceed 10 A and is counted separately (total 

90A worth of breakers).

•  Up to two hold-down kits with screws for the breakers. Each hold-down kit (X-IQ-NA-

HD-125A) will allow installation of up to two breakers located on the same side of the 

busbar (Only for IQ8 PV installations with IQ System Controller).

•  Overcurrent protection in the load center in accordance with NFPA  

70, §705.12.and NEC 690

•  Suitable mounting hardware: use #8 (or larger) screws that are long enough to 

secure the unit to the vertical mounting surface

•  Copper conductors rated for wet locations and sized to meet local code require-

ments and voltage drop/rise considerations. Wire sizes and torque values are 

listed on the door of the unit.

•  UL-listed rain-tight conduit hubs for wire entry into the enclosure.

D )  For consumption metering, check that there is enough space in the load 

center to install CTs. Do not install the CTs in a panel where they exceed 

75% of the wiring space of any cross-sectional area within the load center.

E )  Decide how to connect the IQ Gateway to the Internet: Use Wi-Fi, and  

Enphase Mobile Connect modem, or Ethernet. Then, make sure you have 

the following optional items, if needed:

(Model X-IQ-AM1-240-4C and X-IQ-AM1-240-4)

How It Works

Installing the 

Enphase IQ Combiner 4 

and

 

Enphase IQ Combiner 4C

The Enphase IQ Combiner 4  

and/or the IQ Combiner 4C combine up to  

four AC branch circuits of Enphase IQ  

Series Microinverters and/or Enphase  

IQ Battery batteries.  

To install the IQ Combiner 4 or 4C, read  

and follow all warnings and instructions in this guide.  

Safety warnings are listed on the back of this guide.  

If you do not fully understand any of the concepts,  

terminology, or hazards outlined in these instructions, refer  

installation to a qualified electrician or installer. These instructions 

 

are not meant to be a complete explanation of a renewable energy system.  

All installations must comply with national and local electrical codes.  

Professional installation is recommended.

The IQ Combiner 4C and 4 have an outdoor-rated, NRTL-certified 

 

NEMA type 3R enclosure containing an Enphase IQ Gateway™, circuit breakers,  

a pair of split-core consumption metering CTs, and wiring for IQ Gateway connections.  

The IQ Combiner 4C includes a Enphase Mobile Connect™ LTE-M1  

cell modem. Use the IQ Combiner 4C for single-phase applications and to support the  

AC connections needed for an Enphase residential solar installation.

Generator 

(reserved for future use*)

Enphase Cloud

• 

Enphase Mobile Connect modem (included with X-IQ-AM1-240-4C) 

• 

Ethernet over power line communication (PLC) bridge with Ethernet cables (or-

der EPLC-01). If you choose this option, you must install an Enphase accessory 

receptacle (order XA-PLUG-120-3) inside the IQ Combiner 4/4C.

• 

Ethernet cable: 802.3, Cat5E or Cat6, unshielded twisted pair (UTP). Do not 

use shielded twisted pair (STP) cable. You must install a ferrite bead (we 

recommend Fair-Rite 0431167281) as close as possible to the IQ Gateway 

on the Ethernet cable.

When installing with an Ensemble system, both Enphase Mobile Connect mo-

dem, and additional internet connection (wifi or ethernet) are required.

F )   Make note of the IQ Gateway serial number on the installation map. Later, 

you will need to enter this number in Installer App. You can type it in manually 

or scan the label on the inside of the combiner door. Always keep a copy of 

the installation map for your records.

G )  Note that installation of the IQ Combiner 4/4C has two parts: To ensure 

successful device detection, complete Part 2 after installing any Enphase IQ 

Microinverter, Enphase IQ Battery and/or Enphase IQ System Controller.

IMPORTANT: 

The IQ Gate-

way inside the IQ Combiner is 

required to monitor performance 

of the IQ microinverters and to 

communicate with IQ Battery and 

IQ System Controller.

IQ GATEWAY

P1

C1

C2

1

2

3

4

NO

 Ref

Common

C

Digital Input

Relay

PD, B300

OVC II

 

L1

L2

N

CU, 75C, 14

AWG MIN

MEAS C

AT

 III

OVC III

Production | Consumption

RECOMMENDED ETHERNET 

CABLE  ROUTING

LOAD CENTER

L1

L2

TO IQ

BATTERY / PV 

TO MAIN

LOAD 

CENTER

AC

NEUTRAL

MAIN

LUG

(IF  PV, MUST PASS THROUGH 

PRODUCTION  CT )

TO  PV

CT

Junction 

clip 

Note: On grid forming IQ-8

Systems the IQ Gateway L1 and 

L2 

must NOT 

be wired to the

combiner circuit breaker.

The IQ Gateway L1 and L2 may

be wired to:

-- A double pole breaker on the

generator breaker spot in

IQ System Controller  if the 

spot is unused, or

-- A double pole breaker on the

backed-up loads sub-panel, or

-- A quadplex (BQ220240 or

BQ215240) breaker on the NFT

breaker position in IQ System 

Controller.

 Refer to the Quick Install Guide

for details. 

NE Filter

Board

TO 

IQ Sytem 

Controller

(optional)

Содержание IQ Combiner 4

Страница 1: ...icroinverters and or Enphase IQ Battery batteries To install the IQ Combiner 4 or 4C read and follow all warnings and instructions in this guide Safety warnings are listed on the back of this guide If you do not fully understand any of the concepts terminology or hazards outlined in these instructions refer installation to a qualified electrician or installer These instructions are not meant to be...

Страница 2: ...nd ground Large screw Small screw 14 1 0 AWG 14 6 AWG 5 0 Nm 45 in lb 2 2 Nm 20 in lb Main lug 10 4 AWG 3 2 0 AWG 5 0 Nm 45 in lb 5 6 Nm 50 in lb Copper conductors only rated minimum 75 C Follow NFPA 70 NEC or CSA C22 1 part 1 and all local codes For DG breakers larger than 20 A use wire insulated for 90 C based on 75 C ampacities The busbar supports a maximum of 90A of circuit breakers including ...

Страница 3: ...efore energizing the sensed circuit Load Center To Grid From IQ Combiner IQ Gateway Terminal Block Relay contacts if needed UP TO 250 Vac 100A 0 5V 45 66Hz white blue Not used white blue P1 C1 C2 1 2 3 4 NO Ref Common C Digital Input Relay PD B300 OVC II L1 L2 N CU 75C 14AWG MIN MEAS CAT III OVC III Production Consumption Consumption CTs The arrows must point toward the load away from the grid DAN...

Страница 4: ...e system details are added Step 1 and make sure that an appropriate grid profile is set for the system D Go to Devices Array Step 2 and add the total number of devices in the system Tap edit if you need to edit previously entered data E Input tarrif details in Step3 F Connect to the IQ Gateway with your mobile device smart phone or tablet The AP Mode LED lights solid green when the network is avai...

Страница 5: ...een for the following A For microinverters confirm that the expected number of devices are detected and communicating by navigating to Devices Array Microinverters Array and check that status is Producing B Check that the grid profile is set for all the microinverters Setting the profile may take up to 5 minutes for a typical system C To check if IQ Battery and or IQ System Controller are connecte...

Страница 6: ... Enphase Customer Support if you need to re install the modem at a different site Troubleshooting TROUBLESHOOTING Contact Enphase Customer Support enphase com en us support contact if you have any questions about troubleshooting your system a LED overview LED State Description All Flashing red in unison The IQ Gateway is booting up Flashing green sequentially Software upgrade in progress Network c...

Страница 7: ...failing or that is undersized may not generate enough power for AC conversion d Internet connection issues If you are using Wi Fi and the Network Communications LED remains off or solid red The WPS connection window may have timed out Retry the connection steps Make sure that the broadband router is connected and operational by checking that other devices at the site can access the network Check f...

Страница 8: ...g The operation is permitted for the following two conditions 1 the device may not cause harmful interference and 2 the user of the device must accept any interference suffered even if the interference is likely to jeopardize the operation Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions ...

Страница 9: ...iner 4 only for serving Enphase equipment No other loads are allowed FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency ener...

Отзывы: