Parameters
Topic
Unit
Min
Typical
Max
Miscellaneous Parameters
Maximum
9
microinverters per 20A (max) AC branch circuit
240 VAC (single phase)
208 VAC (single phase)
12
10
CEC weighted efficiency
240 VAC (single phase)
208 VAC (single phase)
%
97.5
97.0
Static MPPT efficiency (weighted, ref EN 50530)
%
99.0
Total harmonic distortion
%
5
Ambient temperature range
C
-40
+60
Night tare loss
mW
50
Storage temperature range
C
-40
+85
Features and Specifications
Compatibility
Pairs with 96-cell PV modules
Dimensions not including mounting bracket
212 mm x 175 mm x 30.2 mm (approximate)
Connector type
Enphase EN4 bulkhead
Weight
1.08 kg (2.38 lbs.)
Environmental category / UV exposure rating
NEMA type 6 / outdoor
Torque specifications for fasteners
(Do not over torque)
•
6 mm (1/4”) mounting hardware: 5 N m (45 - 50 in-lbs.)
•
8 mm (5/16”) mounting hardware: 9 N m (80 - 85 in-lbs.)
•
When using UL 2703 mounting hardware, use the
manufacturer’s recommended torque value
Cooling
Natural convection - no fans
Relative humidity range
4% to 100% condensing
Approved for wet locations
Yes
Pollution degree
PD3
Communication
Power line communication (PLC)
Standard warranty term
Compliance
CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part
15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and
conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-
2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC
conductors, when
installed according manufacturer’s instructions.
Grounding
The DC circuit meets the requirements for ungrounded PV
arrays in NEC. Ground fault protection (GFP) is integrated into
the class II double insulated microinverter.
Monitoring
Enlighten Manager and MyEnlighten monitoring options. Both
options require an Enphase IQ Envoy
Integrated DC disconnect/
Integrated AC disconnect
The DC and AC connectors have been evaluated and
approved for use as the load-break disconnect required by
NEC 690.
9