User’s

 

Manual

Digital Force Gauge

 

Содержание EFGS series

Страница 1: ...User s Manual Digital Force Gauge ...

Страница 2: ...Storage 5 2 6 Browse and Printing 5 3 Menus 3 1 Menus Structure 6 3 2 Measurement 7 3 3 Memory 8 3 4 Printing 10 3 5 System Setting 11 4 Communications Ports 4 1 USB Recharge 13 4 2 Multifunction port 13 5 Maintenance and Calibration 5 1 Charging 15 5 2 Calibration 15 6 Connecting Load Cell 6 1 Connection 17 6 2 Capacity Setup 17 Appendix Packing List 18 Dimension 18 Warranty Card 19 ...

Страница 3: ...onds to power On or Off Save Exit During Measurement Print the current value or store data depending on the key setting In Menus Back or Exit Menu Enter During Measurement Enter the menus In Menus Select or Enter Zeroing Up During Measurement Zeroing In Menus Moves selection up or increases the value Mode Down During Measurement Changes Test Mode In Menus Moves selection down or decreases the valu...

Страница 4: ...ad Saving icon Indicates data is being saved Direction Icon tension compression Tolerance Indicator under lower limit between lower limit and upper limit over upper limit Load Cell The capacity of load cell If no load cell connecting show and twinkling 1 3 Load Cell There are 2 types of load cell can be connected with indicator they are S beam and ring type Fig 1 3 Data Display Graphic Display ...

Страница 5: ...table Display 160 128 dot matrix LCD with LED Backlight Overload 150 of F S LCD flashes beyond 110 of F S Temperature Effects 0 03 FS per C Measurement Mode Track Peak AutoPeak FirstPeak Set Point Tolerance Alarm Sampling Rate 2000 Hz Display Update 10 times sec Memory 1000 data Power 3 6VDC Ni MH rechargeable batteries Battery Life Approximately 12 hours continuous use per full charge Charger Ada...

Страница 6: ... 2 seconds to power On or Off The indicator can identify the load cell You should check the model wheith it is you want Check Battery Icon If the power is low should be recharged 2 4 Testing 2 4 1 Adaptor Select the appropriate adaptor install it in the measurement axis of the load cell Tighten it by hand without the use of tools Do not use a deformed or damaged adaptor NOTE Do not use tools to vi...

Страница 7: ...ure the first peak value of force when the force value decreased to reach the drop ratio The drop ratio can be set in menus 2 4 4 Set Tolerance Limit The tolerance limits can be set for GO NG measurement also If you set the alarm on and a valid limit The icon will be displayed for within limit lower than lower limit or exceed upper limit 2 4 5 Zeroing Touch to clear the force gauge in track mode f...

Страница 8: ... menu Touch can cancel the setting or exit Menu Measurement Unit System Display Mode Group Display Direction Tolerance Power Off Test Mode Backlight Peak Time Key Tone Alarm Date Time Memory Storage Mode Password Browse All Key Setting Browse Selected RS232 Baud rate Delete Selected Default Setting Delete All Capacity Printing Print Recent Language Print Selected Calibration Print All Information ...

Страница 9: ...larm Fig 3 3 3 2 1 Unit The measuring unit can be selected under this menu Different range models may have different unit selection capabilities See Fig 3 4 3 2 2 Group When several test samples need to be measured the samples can be coded into groups The range is 01 99 See Fig 3 5 3 2 3 Tolerance In the Tolerance menu program upper and lower limit for GO NG Measurement Fig 3 4 Fig 3 5 Fig 3 6 Fig...

Страница 10: ...7 See 2 4 3 Select Test Mode also 3 2 5 Peak Time If AutoPeak mode is used you can set the peak value capturing time interval Peak Time Default setting of Peak Time is 5 sec The range is 1 99 seconds Fig 3 8 3 2 6 Alarm You can turn on off the sound of tolerance alarm Fig 3 9 The sound for overload alarm cannot be turned off 3 3 Memory In this menu you can set the memory mode browse the data in me...

Страница 11: ...Auto Peak mode is effective When a peak capture time interval is reached the peak value is saved no need touch any key Fig 3 11 3 3 2 Browse Data You can browse the data in memory with two method Browse All or Browse Selected Fig 3 12 Fig3 13 The greatest number is the most recent data For Browse Selected selecting the range of data number is needed Touch or can turn the page Fig 3 14 Fig 3 15 Fig...

Страница 12: ...ent Print Selected and Print All 3 4 1 Connect Printer Connect the printer to the force gauge with a printing cable Then turn on the power of printer 3 4 2 Printing Setup Print Recent Print some data measured recently Fig 3 16 Print Selected Print data in a number range Fig 3 17 Print All Print all data in memory Fig 3 18 It may take a long time to print all the data and need many printing paper s...

Страница 13: ...rce gauge can turn the power off automatically some time interval after no measuring and no any operation 5 minutes is default You can change it for a longer or shorter standby 3 5 4 Backlight The force gauge can turn off backlight some time interval after no measuring and no any operation You can select this time or turn it on or off always Fig 3 24 3 5 5 Key Tone Fig 3 25 3 5 6 Date Time Fig 3 2...

Страница 14: ...tore the current display value Storage or print the recent data Print Storage is default 3 5 9 Default Setting When the artificial error and do not know how to restore the gauge can be restored to factory settings it will lose that some imformation set by customs Carefully use this function Restoring to Default Setting the password must be enter and a prompt must be confirmed Fig 3 24 Fig 3 25 Fig...

Страница 15: ...e internal Ni MH battery with connecting the recharger 4 2 Multifunction port The assignment of pins is shown in Table 4 1 4 2 1 RS 232 The RS232 serial port is only used to connect the mini printer to print the memory data RS 232 specifications Hardware Flow Control None Data word length 8 bits Stop bit 1 bit Parity None Baud rate 38400 The baudrate can be changed in menus Table 4 1 Pin Assignmen...

Страница 16: ...Pin6 will be connected when an overload alarm occurs If Alarm is turned on Pin7 to Pin6 is connected when the measured value exceed upper limit Pin4 to Pin6 is connected when the measured value below lower limit Maximum permissible voltage pin7 to 6 pin 4 to 6 must be lower than 35V pin 6 to 7 pin6 to 4 must be lower than 6V Fig 4 2 Fig 4 3 ...

Страница 17: ... or the influence of external factors there may be errors in a certain range after a period of time use Should send the force gauge to a specialized testing organization for calibration If you have some stansard force weights or the other standard load and some test stand you may calibrate it also Mount the force gauge Remove the tare by use of the key Enter Calibration interface Fig 5 2 The calib...

Страница 18: ...alibration previously as shown in 3 2 1 Unit Ensure that the tare weight of attachment has been remove before calibration You can do any point or points calibra tion from 1 to 5 point we recommend 5 points calibration For the load cell which can measure pull and push if the force of two directions are used it should be calibrated in both directions separately The calibration data is corresponded t...

Страница 19: ...tify the capacity of load cell which have a identified resistor the capacity setup is not needed 6 2 Capacity Setup If there is no identified resistor the capacity setup is needed Enter Menu System Capacity Select the capacity Touch to confirm the setting Pin Description 1 Power 2 Output 3 Output 4 Power Gnd 5 6 Resistor Table 6 1 Connector Capacity kN Resistance RI kΩ 1 2 2 3 3 5 5 1 10 7 5 20 10...

Страница 20: ...18 Appendix Packing List Dimension Fig A 1 Indicator Load Cell User s Manual USB Cable Recharge Fig A 2 ...

Страница 21: ...05 220 0 05 450 0 1 1100 0 1 2250 0 5 4500 1 2250 0 5 4500 1 11k 0 001k 22k 0 005k 44k 0 01k 100 0 01 200 0 05 500 0 1 1000 0 1 2000 0 5 10000 1 2000 0 5 5000 1 10 0 001 20 0 005 10 0 001 20 0 005 50 0 01 100 0 01 200 0 05 1kN 2kN 5kN 10kN 20kN 10kN 20kN 50kN 100kN 200kN DUM413 03 0000EN1507 S R ...