background image

ENCORE ECOFLEX MANUAL

20

Setup 

KEYBOARD INSTALLATION

STEP 1

Set the keyboard on the keyboard tray

STEP 2

Pull the keyboard tray forward to full extension. 

This will simulate the full length requirement of 

the keyboard cable length. Unlock both sides of 

the work surface and lift up. 

STEP 3

Route the cable (pictured in red) under and 

through the tray routing ports, plug into appro-

priate location on CPU/laptop and zip tie into 

place.

FIG. 2  Underneath view of desk keyboard 

and Mouse Cable Routing Ports

FIG. 1  Top view of desk keyboard and 

mouse cable routing ports

STEP 4

Replace the work surface and cable cover at the 

base of the monitor arm, close and lock, or, con-

tinue to next step and install mouse.

Содержание ENCORE ECOFLEX

Страница 1: ... not part of a contract or license as may be expressly agreed Enovate Medical is a registered trademark of Enovate Medical LLC All product and company names herein may be trademarks of their registered owners All rights reserved 2021 Enovate Medical LLC 7 8 21 Encore EcoFlex Manual ...

Страница 2: ...MOVEMENT 24 HEIGHT ADJUSTMENT LEVER 25 RESTART PC 25 MOBIUSPOWER 26 BATTERY PACK FUEL GAUGE 26 TIME REMAINING ON BATTERY PACK LCD SCREEN SEQUENCE 27 MOBIUSPOWER BATTERY PACK REMOVAL LCD SCREEN SEQUENCE 27 MOBIUSPOWER CHARGING STATION 28 SWAPPING THE MOBIUSPOWER BATTERY 29 ON BOARD CHARGING Encore EcoFlex MobiusPower Plus Model only 29 BATTERY DISPOSAL 30 POWER SPECIFICATIONS 31 ECOFLEX 31 CHARGING...

Страница 3: ...l com download 6709 Encore EcoFlex Quick Start Guide https www enovatemedical com download 6140 Workstation Cleaning Instructions https www enovatemedical com download 4829 Software User Guide https wwwmyenovate com files EcoflexUserGuide pdf COMPANION GUIDES ...

Страница 4: ...to the Enovate Medical workstation frequently employ the use of symbols with or without accompanying text Health products regulatory agencies require the use of symbols often in place of textual statements to enhance the legibility of labeling and thus improve the conspicuousness of required information such as important safety information Your attention to the presence and content of symbols used...

Страница 5: ...ENCORE ECOFLEX MANUAL 5 Encore EcoFlex ...

Страница 6: ...ibit Against an Object Alternating Current The term symbols refers to the use of graphical symbols without equivalent accompanying text Symbols are used by medical device manufacturers to create uniform labels and labeling for the United States European Union and any other countries that may permit their use in medical products The use of symbols on the product labels are intended to conform to in...

Страница 7: ...o through Enovate Medical approved documentation i e this User Manual or other instructions Only Enovate Medical or an Enovate certified entity may service or replace the cart components If any component on the cart is missing or damaged the cart must not be used Contact Enovate Medical immediately to request service MAINTENANCE During preventive maintenance workstation should be turned off by rem...

Страница 8: ...TAGES AND THE COVER SHOULD NOT BE REMOVED All service or maintenance work should be carried out by qualified service personnel by contacting Enovate Medical at 888 909 8930 GROUNDING Connect the Enovate workstation or bay charger to an equivalent receptacle marked Hospital Only or Hospital Grade to ensure ground WARNING To avoid risk of electric shock this equipment must only be connected to a sup...

Страница 9: ...ant direct sunlight can severely damage it The EcoFlex Power Management system has no user serviceable internal parts To maintain your warranty refer all servicing to Enovate Medical qualified personnel Do not cover or obstruct any venting holes on the EcoFlex Power Management Controller or the MOBIUSPOWER Charging Stations Store the EcoFlex Power Management system within 10 to 30 degrees Celsius ...

Страница 10: ...wing Ambient Temperature Range 20 C to 50 C 4 F to 122 F Atmospheric Pressure 50 kPa to 106 kPa Relative Humidity 5 to 85 non condensing STORAGE REQUIREMENTS The lithium ion Battery Pack must not be fully charged prior to storing 50 state of charge recom mended OPERATING ENVIRONMENT Ambient Temperature Range 0 C to 40 C 32 F to 104 F Atmospheric Pressure 50 kPa to 106 kPa Relative Humidity 20 85 n...

Страница 11: ...g the equipment off and on the user is encouraged to try to correct the interference using one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and the receiver connect the equipment into an outlet on a circuit different from that which the receiver is connected consult the dealer or an experienced radio television technicia...

Страница 12: ...d by shipping Immediately after receiving you products ALL batteries must be fully charged to ensure the duration of their warranty NOTE All Pictures shown are for illustration purpose only Actual product may vary due to product enhancement STEP 1 Use scissors or a utility knife to cut and remove the two outer straps ...

Страница 13: ...cardboard wall and any packing spacers STEP 3 Lift cart with foam castor braces still attached out of the cardboard base and remove foam caster braces STEP 4 Open tray and check for integration kit and locate all optional accessories NOTE STEP 3 requires two people ...

Страница 14: ...ghtLine Monitor Arm EcoFlex Power Management System Breakaway Cord Locking Casters MobiusPower Holster Desktop Security Lock Left and Right Side Handle Bar Keyboard Tray Large Work surface OPTIONAL FEATURE BASED ON MODEL MobiusPower Battery Pack OVERVIEW ...

Страница 15: ...rview LCD Message Center Up Down Height Adjustment Lever Mouse Holder Restart PC Button Left Right Mouse Trays Shown in Extended Position Electronic Keypad Depress momentarily to restart PC or 10 seconds to restart the workstation ...

Страница 16: ...7 3 kg 16 lbs Monitor Arm 4 1 kg 9 lbs CPU Compartment 4 5 kg 10 lbs Work Surface 4 5 kg 10 lbs Keyboard Tray 3 lbs Column Accessories 4 5 kg 10 lbs Column Drawer 9 1 kg 20 lbs CPU COMPARTMENT SIZE Width 406 4mm 16 Depth 330 2mm 13 Height 57 2mm 2 25 I O PORTS Channel 1 PC Channel 2 Monitor Channel 3 Peripheral 1 2 3 1 2 3 14 50 13 00 ...

Страница 17: ... cover to allow the monitor to extend fully upward SIGHTLINE MONITOR ARM INSTALLATION STEP 4 Continue routing each cable behind the arm and through the rear cable port at the base of the monitor arm and plug into computer port STEP 1 Align screws with the four holes in the monitor pole VESA plate Hold the monitor in place and tighten the screws SETUP SIGHTLINE MONITOR ARM TENSION ADJUSTMENT STEP 2...

Страница 18: ... cable inputs and sizes INCLUDING monitor input power input mouse keyboard and any peripherals Make cable connections within the tray VOLTAGE SETTINGS can be changed using EM Control or the Rhythm Unplugged app For additional information please visit http software myenovate com CPU INSTALLATION I O PORTS Channel 1 PC Channel 2 Monitor Channel 3 Peripheral 1 2 3 ...

Страница 19: ...of the work surface and lift up STEP 3 Route the cable pictured in red under and through the tray routing ports plug into appro priate location on CPU laptop and zip tie into place FIG 2 Underneath view of desk keyboard and Mouse Cable Routing Ports FIG 1 Top view of desk keyboard and mouse cable routing ports STEP 4 Replace the work surface and cable cover at the base of the monitor arm close and...

Страница 20: ...y to full extension This will simulate the full length requirement of the mouse cable length STEP 2 Route the cable under and through the tray routing ports plug into appropriate location on CPU laptop and zip tie into place FIG 1 Top view of desk keyboard and mouse cable routing ports MOUSE INSTALLATION ...

Страница 21: ...ex insert a fully charged MobiusPower Battery Pack or plug into an outlet POWERING ON As the Encore EcoFlex is powering on you will see a series of screen displays For full details please visit http software myenovate com files EcoflexEncoreUserGuide pdf OPERATIONS ...

Страница 22: ...ENCORE ECOFLEX MANUAL 23 Operations SWAPPING THE MOBIUSPOWER BATTERY Remove MobiusPower battery pack from holster swap with a fully charged battery from the charging station ...

Страница 23: ...OFLEX MANUAL 24 Operations Upright Position Extended Position Reclined Position SIGHTLINE MONITOR ARM MOVEMENT Monitor rotates 80 degrees For safe travel lower the Sightline Monitor Arm to the reclined position ...

Страница 24: ...adjustment lever located on the left side of the Encore STEP 2 Pull the height adjustment lever upward to raise or lower to desired position STEP 3 Release the height adjustment lever once the desired position is reached HEIGHT ADJUSTMENT LEVER RESTART PC Depress Momentarily to restart PC Press and hold for than 10 seconds to restart the workstation ...

Страница 25: ...maining charge on a Battery Pack press and release the white circle on the Battery Pack s fuel gauge display The charge level is indicated in 25 increments by the number of status lights appearing between the E Empty and F Full After 3 seconds the status lights will turn OFF Charge Capacity LED 1 LED 2 LED 3 LED 4 0 10 FLASH OFF OFF OFF 11 25 ON OFF OFF OFF 26 50 ON ON OFF OFF 51 75 ON ON ON OFF 7...

Страница 26: ...ower your computer and any other devices requiring power will shut down until the Battery Pack is replaced with a Fully Charged Battery Pack OR the Battery Holster is plugged into an AC outlet using the optional Holster Charger You may then turn on your computer and other electronic devices LCD displays Battery Removed when the MobiusPower battery pack is removed from the workstation holster The w...

Страница 27: ...GED Solid green light CHARGING Blinking green light ERROR Solid or blinking yellow light Charge Indicator Lights MobiusPower Dual Pack Charging Station MOBIUSPOWER HOLSTER CHARGER To charge the MobiusPower battery pack in the holster plug the power cord into an AC electrical outlet The LCD message center will read AC Plugged In Charging The charge status can be checked by unplugging the AC power c...

Страница 28: ...n the EcoFlex is being powered by the backup battery The Encore EcoFlex MobiusPower Plus can charge the MobiusPower battery pack while the battery pack is in the holster To begin charging your Encore Ecoflex MobiusPower Plus plug the 3 prong power cable into a standard 110 120VAC grounded AC power outlet You will observe the following message on the LCD when the AC cord is connected Please unplug ...

Страница 29: ...m Batteries are consumable goods Recycling MOBIUSPOWER Batteries Rechargeable batteries power everything from portable phones and cordless phones to laptops and PDAs Batteries are a unique product comprised of heavy metals which include nickel cadmium alkaline mercury nickel metal hydride and lead acid which can threaten our environment if not properly discarded or handled There are many ways to p...

Страница 30: ...tage 120V 10 120V 10 Input Frequency 60Hz 60Hz Input Current 3 6 Amps max 7 2 Amps max Output Voltage 12 6 VDC 12 6 VDC Output Current 8 5 A per bay max 8 5 A per bay max Output Power 115 Watts max per bay 115 Watts max per bay Measurements 32 cm 12 6 H x 43 2 cm 17 W x 14 7 cm 5 8 D 32 cm 12 6 H x 68 6 cm 27 W x 14 7 cm 5 8 D Model EC MP EC PF EC M2 EC M4 EC ME EC EF Input Voltage 120 VAC 10 8 VD...

Страница 31: ...61 W nominal Output Protection Yes Overload Recovery Yes Overload Protection Yes MAIN POWER CONTROLLER ENCORE ECOFLEX Holster Assembly Encore EcoFlex Input Voltage 8 5 VDC 15 VDC Input Frequency DC Input Current 30 A max MOBIUSPOWER BATTERY HOLSTER Model Protek Power PMP150 12 HI Input Voltage 90 VAC 264 VAC Input Frequency 47 Hz 63 Hz Input Current 2 A rms for 115 VAC 1 A rms for 230 VAC Output V...

Страница 32: ...C Input Voltage Shutdown at 10 V Auto reset at 11 5 V High DC Input Voltage Shutdown at 16 5 V Auto re set at 16 5 V Short Circuit Overload Output voltage drops but does not shut down Auto reset on removal Over Temperature Shut down when internal hot spot if 105 C 221 F Auto reset on cooling Reverse Polarity on DC Input Side Automotive Mini Blade Fuse 32 V 15 A Compliance Safety Conforms to ANSI A...

Страница 33: ...NG INSTRUCTIONS Nonabrasive cleaners or mild cleaning solutions should be used As a precaution we recommend testing the suitability of a cleaning product by applying to an inconspicuous area minimizing the time of exposure and the amount of cleaning agent used dilute as recommended by the supplier to pre vent any damage to the surface TESTED AND APPROVED CLEANING AGENTS Quaternary ammonium compoun...

Страница 34: ...aner Virex 256 or Micro 90 is not recommended To avoid risk of electric shock do not expose electrical components to water cleaning solutions or other potentially corrosive liquids or substances Do not immerse the cart or cart components in liquid or allow liquids to flow into the cart Wipe cleaner off surface immediately using a damp cloth Thoroughly dry surface after cleaning Do not use flammable...

Страница 35: ...t frayed twisted or damaged Ensure the inner cores of power supply cords are not exposed where they connect to equipment plugs and or sockets Ensure inner cores of power supply cords are not exposed or twisted along the cord s length Ensure there are no exposed unprotected electrical conductors Ensure electrical tape or anything that can cover damage has not been applied to power supply cords and ...

Страница 36: ...1152 Park Avenue Murfreesboro TN 37129 p 888 909 8920 www enovatemedical com support enovatemedical com 2021 Enovate Medical LLC All Rights Reserved ...

Отзывы: