background image

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

4/11

©2011 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.

AMX reserves the right to alter specifications without notice at any time. 

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com

    93-1350-01

 

REV: C 

AxLink Port

All AVX-400-SP units have an AxLink port and adjacent status LED. This port allows the 
unit to be controlled from any AxLink Master such as a NetLinx Integrated Controller. A 
green LED shows AxLink data activity.

Note:

 

The AVX-400-SP cannot be powered by this port or used to power other devices.

AxLink DEVICE DIP Switches

The 8-position AxLink DEVICE DIP switch sets the AxLink identification number for 
your AxLink device. Consult the 

Enova AVX-400-SP Cat5 Presentation Switcher 

Operation/Reference Guide

 for information on DIP switch settings.

Configuration Port

The AVX-400-SP contains one low-speed type-B USB connector (labelled PROG) 
located on the front of the unit. Use a standard USB cable to establish a connection 
between the device and your PC's USB port. This connection enables you to program 
the switcher by using AMX DCS software.

Warning:

 Install the DCS software on your PC before connecting a USB cable between 

the PC and AVX-400-SP. Failing to do so may cause an installation error.

Power Connector

The AVX-400-SP uses a 12 VDC-compliant power supply to provide power to the 
switcher through the front 2-pin 3.5 mm mini-Phoenix power connector.

Warning:

 This unit should only have one source of incoming power. Using more than 

one source of power to the Controller can result in damage to the internal components 
and a possible burn out. Apply power to the unit only after installation is complete.

Supression Ferrite Installation

If you are in a location with 240V of power, you must clip the supplied Suppression 
Ferrite around the power cable 

(no tools required)

.

 

1.

Release the latch to open the plastic enclosure.

2.

Insert the power cable and close the enclosure.

AMX DCS Software

You can configure the AVX-400-SP and its functionality by using AMX DCS software. 
The top of the window displays the device image of the front panel of the Enova 
AVX-400-SP, and displays which inputs are valid by highlighting the source input. 
Clicking on a highlighted port on the device image changes the active input. The active 
source input is indicated by the illuminated red LED beside the source input. The 
bottom half of the window features the Device Setup options (FIG. 7)

.

Enabling Display Control

Display control enables you to select a display to use for the output from your source 
inputs. A display can be any type of video output device. After enabling display control, 
you can select a make, type, and model of display. If your display is not available from 
the options menus, see the Device Library Manager section in the 

Enova AVX-400-SP 

Cat5 Presentation Switcher Operation/Reference Guide

 for information on adding your 

specific device to the device library.
Perform these steps to enable display control:

1.

Click the 

Display

 tab on the AMX DCS window (FIG. 8).

2.

Click the 

Enabled

 check box to enable display control.

3.

Select a 

Make

Type

, and 

Model

 display from their respective fields.

4.

Click 

Program Device

 to send the display device’s commands to the 

presentation switcher.

Switching Mode

Setting the switching mode enables you to control how a source input is activated. You 
can choose from Take-over mode, Toggle mode, and priority switching. Take-over mode 
enables you to activate a source input by pressing the button on the corresponding wall 
input plate. With toggle mode, if you press the button on any of the wall plates, then the 
selected video input changes to the next available input.

Priority Switching

Priority switching enables you to establish a priority order for displaying each input 
device. The input device with the highest priority will always be sent to the output 
display as long as the input device remains powered on. When the power to the highest 
priority input device is turned off, the signal from the next active input device appears on 
the output display.
For example, you have a DVD player set at priority 1, a PC at priority 2, and a VCR at 
priority 3. If the PC is always powered on, it’s output is sent to the display provided the 
DVD player is currently powered off. When the DVD player is powered on, its output is 
immediately sent to the display. Powering off the DVD player returns the PC’s output to 
the display. The VCR’s output is only sent to the display if it is powered on, and the DVD 
player and PC are both powered off.
Perform these steps to set up priority switching:
1.

In the Device Setup area, click the 

Display 

tab.

2.

Click the 

Priority Switching

 option button in the Switching Mode section.

3.

Use the options menus in the Priority Switching area to indicate the priority order 
for each input device. The number you select from the drop-down menu is the 
source input number on the presentation switcher. For example, if you want 
source input 3 to have the highest priority, select 3 from the first menu.

4.

Click 

Program Device

 to send the new settings to the presentation switcher.

Updating Firmware

AMX DCS software provides a simple interface for updating your AVX-400-SP with the 
latest available version of firmware. You must use a .bin file to upgrade the firmware 
through AMX DCS software. The latest firmware files can be found at the Tech Center 
at 

www.amx.com

.

Perform these steps to update the firmware for your device:
1.

From the File menu, select 

Enova Firmware Update

. The Enova Firmware 

Update window opens.

2.

Click 

Go to AMX.com

. A web browser opens and navigates to www.amx.com.

3.

Click 

Tech Center

 on the main page at AMX.com.

4.

Locate and download the latest firmware version (.bin) for your device. Make note 
of the location to which you save the firmware file. When the download is 
complete, return to the Enova Firmware update window.

5.

Click 

Select File

, navigate to the location the firmware file was saved, and select 

the file.

6.

Click 

Update

. The firmware for the device is updated with the latest version.

7.

Click 

Close

 to close the window and return to the AMX DCS window.

FIG. 4  

RS-232 DB9 (male) connector pinouts for the rear Display Control connector

FIG. 5  

Configuration port (PROG)

FIG. 6  

Installing the Suppression Ferrite

1 2 3 4 5

6 7 8 9

Pin 2: RX signal
Pin 3: TX signal
Pin 5: GND

RS-232 pinouts (male connector)

1

2

3

(complete)

FIG. 7  

AMX DCS window

FIG. 8  

AMX DCS window - Display tab

Отзывы: