Once a day
Check that the power supply cable is in perfect condition; if not replace it with another one of the same
type.
16.FAULTS AND POSSIBLE SOLUTIONS
For troubleshooting and related repairs, refer to the table below.
FAULT
POSSIBLE CAUSE
POSSIBLE SOLUTION
The refrigeration
system does
Not start.
Themachine is un plugged.
From the current socket.
Plug in correctly.
The power supplì cable is damaged or
interrupted.
Check the condition of the cable.If
necessary contact a qualified technician
to replace it with another one of the
same type.
The mains bipolar switch is off.
Turn the mains bipolar switch on.
Power failure on controls.
Check the condition of the controls If
necessary,contact a qualified
technician
to restore the current.
There is a current interruption on the
controls.
Ad just the thermoregulator as come
shown in chapter n°13.
The compressor does not work.
Check the condition of the.
compressor. If necessari contact a
qualified technician to replace it with
another one of the same type.
The machine
temperature is
Not colde nough.
The thermoregulator is not correctly set.
Ad just the thermoregulator as come
shown in chapter n°13.
The machine is installed near a
heat
source.
Move the machine a way from the heat
source as described in chapter n°12.
The machine ispositione dless than 15cm
away from surrounding obstacles.
Move the machine away from the
surrounding obstacles,as shown in
Chapter12.
The air circulation via the ventilation
apertures is obstructed.
Free the ventilation apertures.
There is an interruption in the refrigeration
circuitor there is
no gas.
Contact a qualified technician to check
that the gas expansion
temperature.
The machine
temperature is
too
cold.
The thermoregulat or is not set
to the
correct position.
Ad just the thermoregulator as come
shown in chapter n°13.
Ice on the innner
backside
The door has been kept open for a long
time or the inside temperature is too low.
. Check the hermetic lock of the door.
Increase automatic defrosting. Set
manual defrosting.
Set thermoregulator as indicated in
chapter 13.
Water on the bottom
of the machine.
The defrosting water outlet is clogged.
Check that there are no impurities
on
the drainer.
The machine is not plugged into the
current socket.
Plug the machine in correctly.
29 CT68900001_
Rev.00 07/13
Содержание A1DOGEFBM20/W
Страница 2: ... DOGE ISOLA SVT FISSA DOGE ISOLA QUADRA DOGE LUXUS ISOLA 2 CT68900001_Rev 00 07 13 ...
Страница 93: ...ADJUNTO B MONTAJE PLANES DE PERÍMETRO ПРИЛОЖЕНИЕ Б УСТАНОВКА ПЕРИМЕТРАЛЬНЫХ ПОЛОЧЕК 93 CT68900001_Rev 00 07 13 ...
Страница 94: ...94 CT68900001_Rev 00 07 13 ...
Страница 95: ...95 CT68900001_Rev 00 07 13 ...