5.
STM 33x will only send a LEARN telegram if an “Manufacturer ID” is configured.
Change “Manufacturer ID” for example to EnOcean GmbH.
6.
You can change the wake up cycle, but keep in mind, this will heavily affect the
energy budget. For details see STM 31x user manual.
Typical values for OEM products are:
Cyclic wake-up cycle:
100s (wake up and check temperature value)
Redundant retransmission min:
7 (min send interval every 7. wake up)
Redundant retransmission mx:
14 (max send interval every 14. wake up)