AirGuard
TM
5
www.bullard.com
AirGuard Specifications
Enclosure:
Polypropylene case
No. of Breathing Air Lines:
1, 2, 4 or 8
Size /Weight:
1-
line: 19.2 lbs, 18.7” x 13.2” x 7”
2-line: 24.6
lbs, 22.6” x 15.8” x 7.6”
4-
line: 31.6 lbs, 26.4” x 19.6” x 9”
8-
line: 34 lbs, 26.4” x 19.6” x 9”
Operating Environment Conditions:
Temperature - (32°F to 104°F) (0°C to +40°C)
Ambient Humidity - (10% to 95% RH, non-condensing)
Altitude Sea Level +400M
Storage Environment Conditions:
Temperature - (5°F to 140°F or -15°C to +60°C)
Altitude Sea Level +1,200M
Storage Ambient Humidity:
10% to 95% RH, non-condensing
Power Supply:
100-260 VAC 50/60 Hz (< 10 Watts average) to run unit and/or charge battery.
Internal Battery:
12V / 7Ah rechargeable lead-acid, removable
Battery Life:
10 hours (typical)
Local Alarm Signal:
Color display background and high intensity audible (90 dB) horn
Remote Alarm Signal:
Remote alarm jack with 12VDC output
Pollution Degree Rating:
3
Water Resistance:
IP42
Agency Approvals:
UL 61010 (US & Canada)
Warranty:
2-years parts & labor (excluding instrument calibration and expendable parts such as calibration gas,
filters and batteries)
Содержание Bullard AirGuard AGP
Страница 1: ...AirGuardTM Operators Manual Revision 2 08 31 January 2022 ...
Страница 12: ...12 www bullard com The following chart illustrates the CFM delivered at different inlet pressures ...
Страница 28: ...28 www bullard com Below is an example of the fail screen due to low flow and resulting sensor response ...
Страница 34: ...34 www bullard com After parameter selection the log will open in Excel for further data and plotting analysis ...
Страница 39: ...AirGuardTM 39 www bullard com Notes ...