background image

Spec.No: MGL9050

Page 6 of 11

DATE:

28/07/2020

3.4

 

Appearance

There shall be no such defect as flaw, crack, rust, leakage, which may adversely affect commercial
value of battery.

 

3.5

 

Initial

 

Performance

 

Test

Table

 

2

Item

Test

 

Method

 

and

 

Condition

Requirements

(1) Open-Circuit

Voltage

The

 

open-circuit

 

voltage

 

shall

 

be

 

measured

 

within

 

24

 

hours

 

after

 

standard

 

charge.

≥4.0V

(2) Internal impedance

Internal

 

resistance

 

measured

 

at

 

AC

 

1KHz

 

after

 

50%

 

charge.

≤180mΩ

(3) Minimal Rated

Capacity

The

 

capacity

 

on

 

0.2C

 

discharge

 

till

 

the

 

voltage

 

tapered

 

to

 

2.75V

 

shall

 

be

 

measured

 

after

 

rested

 

for

 

30min

 

then

 

finish

 

standard

 

charge.

Discharge

 

Capacity

≥670mAh

3.6

 

Temperature

 

Dependence

 

of

 

discharge

 

capacity

Batteries

 

shall

 

be

 

charged

 

per

 

3.3.1

 

and

 

discharged

 

@

0.2Cto

 

2.75

V.

 

Except

 

to

 

be

 

discharged

 

at

 

temperatures

 

per

 

Table

 

3.

 

Batteries

 

shall

 

be

 

stored

 

for

 

3

 

hours

 

at

 

the

 

test

 

temperature

 

prior

 

to

 

discharging

 

and

 

then

 

shall

 

be

 

discharged

 

at

 

the

 

test

 

temperature.

 

The

 

capacity

 

of

 

a

 

cell

 

at

 

each

 

temperature

 

shall

 

be

 

compared

 

to

 

the

 

capacity

 

achieved

 

at

 

23

 

ºC

 

and

 

the

 

percentage

 

shall

 

be

 

calculated.

 

Each

 

battery

 

shall

 

meet

 

or

 

exceed

 

the

 

requirements

 

of

 

Table

 

3.

Table

 

3

 

Discharge

 

Temperature

-10

0

23

60

Discharge

 

Capacity

 

0.2C

40%

70%

100%

95%

Содержание MGL9050

Страница 1: ...1 of 11 DATE 28 07 2020 Lithium Ion Battery Pack Specification MODEL MGL9050 Prepared By Date Checked By Date Approved By Date 28 07 2020 28 07 2020 July 28th 2020 Customer Approval Signature Date Company Name Company Stamp ...

Страница 2: ...Spec No MGL9050 Page 2 of 11 DATE 28 07 2020 Amendment Records Edition Description Prepared by Approved by Date A First Publish 28 07 2020 ...

Страница 3: ... Nominal Voltage 3 7V Mean Operation Voltage 3 Voltage at end of Discharge 2 75V Discharge Cut off Voltage 4 Charging Voltage 4 2V IEC standard 5 Internal Impedance 180mΩ Internal resistance measured at AC 1KHZ after 50 charge The measure must uses the new batteries that within one week after shipment and cycles less than 5 times 6 Standard charge Constant Current 0 5C Constant Voltage 4 2V 0 01C ...

Страница 4: ...rge Current 1A Limited by PCB 9 Operation Temperature Range Charge 0 45 60 25 R H Bare Cell Discharge 10 60 10 Storage Temperature Range Less than 1 year 20 25 60 25 R H at the shipment state less than 3 months 20 40 Less than 7 day 20 65 11 Weight Approx 16g FYI 12 Max Pack Dimensions Length 43 0mm Width 31 0mm Thickness 7 5mm ...

Страница 5: ... than 10kΩ V 3 2 3 Ammeter Standard class specified in the national standard or more sensitive class Total external resistance including ammeter and wire is less than 0 01Ω 3 2 4 Impedance Meter Impedance shall be measured by a sinusoidal alternating current method 1kHz LCR meter 1kHz LCR 3 3 Standard Charge Discharge 3 3 1 Standard Charge Test procedure and its criteria are referred as follows 0 ...

Страница 6: ...ill the voltage tapered to 2 75V shall be measured after rested for 30min then finish standard charge Discharge Capacity 670mAh 3 6 Temperature Dependence of discharge capacity Batteries shall be charged per 3 3 1 and discharged 0 2Cto 2 75V Except to be discharged at temperatures per Table 3 Batteries shall be stored for 3 hours at the test temperature prior to discharging and then shall be disch...

Страница 7: ...nspection After full charge with standard charge store at 60 3 60 10 RH for 1 month 4 Mechanical characteristics and Safety Test Table 5 Mechanical characteristics No Items Test Method andCondition Criteria 1 Vibration Test After standard charging fixed the cell to vibration table and subjected to vibration cycling that the frequency is to be varied at the rate of 1Hz per minute between 10Hz an 55...

Страница 8: ...sh Fully charged Each test sample battery in turn is to be short circuited by connecting the and terminals of the battery with a Cu wire having a maximum resistance load of 0 1Ω Tests are to be conducted at temperature 60 2 No explosion No fire The Temperature of the surface of the Cells are lower than 150 Impact Fresh Fully charged A 56mm diameter bar is inlayed into the bottom of a 10kg weight A...

Страница 9: ...tVDET2 Over discharge detection delay time 36 290mS VREL2 Over discharge release voltage Need recharge to release Overcurrent protection VDET3 Over current detection voltage 0 15 0 015V IDP Over current detection current 2 4 5A tVDET3 Detection delay time 4 5 18mS Release condition Cut load Short protection Detection condition Cut short circuit TSHOR T Detection delay time 220 380μS Release condit...

Страница 10: ...ied or damaged charger Do not leave battery in charger over 24 hours Storage Store the battery in a cool dry and well ventilated area Disposal Regulations vary for different countries Dispose of in accordance with local regulations 7 Battery operation instruction 7 1 Charging Charging current Cannot surpass the biggest charging current which in this specification book stipulated Charging voltage D...

Страница 11: ...the Batteries The battery should store in the product specification book stipulation temperature range If has surpasses above for six months the long time storage suggested you should carry on additional charge to the battery 8 Period of Warranty The period of warranty is a year from the date of shipment We guarantees to give a replacement in case of cells with defects proven due to manufacturing ...

Отзывы: