Base Channel Calculations
Please refer to
Step 4
of the
Frame Installation
instructions shown on
page 12.
Door sizes
(mm)
Height = S/O -95mm
Clear
openings
(mm)
Structural
openings
(mm)
Wall construction preparation
The Motus Enigma system can be fitted to steel or
timber studwork partitions. If using steel you must ensure
the head stud is strong enough to take the door weight.
IMPORTANT INSTALLATION NOTES
M O T U S N F R V › I N S T A L L A T I O N G U I D E
|
W A L L C O N S T R U C T I O N P R E P A R AT I O N
1. Studwork size
The studwork size required is
94mm
.
If using steel studs a 94mm head and base track and
92mm uprights should be used.
2. Steel studs
If using steel studs, timber inserts are required within
the studs to provide additional strength and purchase
for 60mm track screws.
3. Doors above 2300mm
If the door height you are installing is above 2300mm
then using 2 layers of plasterboard is recommended.
To order kits to suite two layers of plasterboard add
the suffix (145) to the product code.
4. Self-supporting Head
For situations in high rise buildings where you cannot
fix to the ceiling or soffit then use the Enigma Self-
supporting Head installation detail.
Follow standard Enigma instructions to calculate your
studwork structural opening and add the following
dimensions:
Width +92mm
and
44mm
.
Refer to the specific Self-supporting Head installation
instructions for further details.
Width Single
Width Double
Height
1870
3700
Door +95mm
2120
4200
Door +95mm
2370
4700
Door +95mm
Width
Min. Height
Max. Height
Min. Single
Max. Single
Min. Double
Max. Double
875
1500
2815
600
844
1000
1710
845
969
1711
1960
970
1094
1961
2210
1000
1500
2815
1125
1500
2815
M O T U S T R A C K S I Z E
ITEM
1750mm
2000mm
2250mm
Dimensions
Motus NFR V
7
Bespoke requirements?
Enigma can be customised to suit bespoke projects.
In principle, the installation process remains the same,
however certain installation dimensions may differ.
Please contact the Selo team to discuss your bespoke
requirements.
020 3880 0339
SELF-SUPPORTING HEAD
Follow the standard Enigma instructions to calculate your studwork structural
opening and add the following dimensions:
Width +92mm
and
44mm
IMPORTANT
If installing
Self-supporting Head