     For proper operation the chimney connector should be as short as possible and 
never exceed a six-foot (6’) horizontal run. Horizontal runs of chimney connector pipe 
should have an upward slope of one quarter of an inch (1/4”) per foot. You will need 
to maintain eighteen inches (18”) of clearance from the wall and ceiling unless you 
are using double wall or shielded pipe. 
 

Hot Air Hook-Up 
 

        

You are now ready to distribute air from the 8” outlet on the top of the stove into your existing 

duct system. Always install the add-on-furnace’s 8” diameter supply duct to the hot air trunk line 
of your existing hot air system, as close to the vent fan as possible. Thirty (30) gauge pipe or 
heavier should be used to make this connection; using the least possible amount of pipe will help 
the heat transfer to your duct system.  Cut an eight-inch diameter hole in the main trunk line of 
the existing furnace duct, which is usually located on the top of the central furnace. Slide the 
eight-inch pipe from the add-on-furnace into the hole and seal the connection with duct tape.  

NOTE

:  Install a 8” 90 degree elbow inside this hole so that air flow from central furnace will not 

be directed back into the hot air pipe from the add-on furnace.   
       Thirty gauge or thicker black pipe should be used for the first two feet and then thirty gauge 
or thicker galvanized pipe can be used to connect to the existing furnace duct. Sheet metal 
screws should be used to secure each joint of pipe and an aluminum heat resistant tape can be 
wrapped around each joint to give an airtight seal. 
       The CA-18 blower can be installed by sliding the flange on the blower into the channel track 
located at the bottom and rear of the unit. 
       The AC-12 thermostat can be installed by plugging the 110 connection into the wall and the 
opposite end into the blower. The magnetic thermal disc should be attached to the rear wall of the 
stove in such a manner that the power cord does not come into contact with the stove. The 
thermostat will turn the blower on at approximately 140 degrees and shut the blower down at 
approximately 90 degrees. The frequency of the blower cycle will be affected by the placement of 
the thermostat on the rear of the unit.  Mounting the thermostat closer to the blower will allow the 
blower to come on less frequently. We recommend the thermostat be placed in the center of the 
rear wall as a starting point. 

 

 

SECTION IV:   OPERATING INSTRUCTIONS 
 

A.  Building a Fire  
 

 

CAUTION:  NEVER USE KEROSENE, GASOLINE, DIESEL FUEL OR CHARCOAL 

                   LIGHTER FLUID TO LIGHT OR RE-KINDLE A FIRE. 
 
NOTICE:

  

Your new unit and the connector pipe may smoke for a short period of time. This 

is called “cooking out” and is no cause for alarm. It is a good idea to open all doors and 
windows in your dwelling during the first few hours of operation. 
 

1.  Place several wads of crushed paper over the entire bottom of the stove.  
2.  Place small dry sticks (kindling) of wood on the paper. 
3.  Be absolutely sure there are no combustibles in the immediate area of the stove. 
4.  Open the two cast iron dampers on the door by turning them counterclockwise. 

 

5.  Ignite the paper and leave the door cracked open until the fire is burning freely. 
6.  Once the kindling is burning freely, add several pieces of split dry wood to the fire. 

Allow this wood to start burning well before closing the door completely. 

7.  Close the door and adjust the cast iron dampers on the door by turning them clockwise. 

 
 

Содержание 24-G

Страница 1: ...the flue pipe to any combustibles unless you are using shielded or double wall pipe Visit our web site at www englandsstoveworks com for helpful information frequently asked questions parts accessory...

Страница 2: ...equal to or greater than the area of the flue collar on the stove If the area of the flue is greater than the collar it should never be more than three 3 times greater Example The area of a six inch...

Страница 3: ...d out the roof This is the most direct route and creates a good draw because it requires less pipe It is less expensive because insulated pipe is needed only from the ceiling to the roof and above sin...

Страница 4: ...ry important that you check with local officials Note Flue systems and flue pipe are not furnished with the unit SECTION III FREESTANDING PLACEMENT AND INSTALLATION The first problem you may encounter...

Страница 5: ...ange on the blower into the channel track located at the bottom and rear of the unit The AC 12 thermostat can be installed by plugging the 110 connection into the wall and the opposite end into the bl...

Страница 6: ...ne good load of seasoned wood Prior to loading with new wood pull the hot ashes to the front edge of the stove and fill the unit with seasoned wood Allow the stove to burn freely for at least fifteen...

Страница 7: ...ult task however we highly recommend a professional be contacted for this job He can not only clean the system but will be able to perform a complete inspection of it A professional can spot problems...

Страница 8: ...re will form at the coolest point in your chimney system and at this point will tend to form creosote The ash is picked up by the moisture in the system and will build up or run back down the inside o...

Страница 9: ...apply if damage occurs because of an accident improper handling improper operation improper installation abuse or unauthorized repair made or attempted to be made The manufacturer is not liable for i...

Страница 10: ......

Страница 11: ...Date _________________ Purchase Price ____________________ Serial Number _____________________ Mfg Date ______________________ How did you first hear about our product please check one ___ Word of Mou...

Отзывы: