SECTION III: IMPORTANT OPERATION INSTRUCTIONS
“Draft” is the force that moves air from the appliance up through the chimney. The amount of draft
in your chimney depends on the length of the chimney, local geography, nearby obstructions, and
other factors. Too much draft may cause excessive temperatures in the appliance. An uncontrolled
burn or a glowing red part or chimney connector can indicate excessive draft. Inadequate draft may
cause back puffing into the room and “plugging” of the chimney and/or cause the appliance to leak
smoke into the room through appliance and connections.
Today’s solid fuel appliances are much more efficient than in the past. The units are designed to
give you controlled combustion, as well as maximum heat transfer, using less fuel to do so.
The design of your new appliance is such that the exhaust “smoke” is now at lower temperatures
than in the past, therefore requiring proper chimney size to give adequate draft. If your chimney is too
large, the heating appliance will have a difficult time to raise the “chimney flue” temperature to give
adequate draft, therefore causing a smoke back up, poor burn, or both.
Should you experience such problems, call in a local chimney expert.
With the door closed, the rate of burning is regulated by the amount of air allowed to enter the unit
through the air control. With experience, you will be able to set the control for heat and burning time
desired.
Illustration 1
CLEARANCES:
A = 13 inches (330 mm)
B = 16 inches (407 mm)
C = 11 inches (280 mm)
D = 20 inches (508 mm)
E = 16 inches (407 mm)
F = 8 inches (204 mm)
*IMPROPER INSTALLATION:
The manufacturer will not be held responsible for damage caused by
the malfunction of a stove due to improper installation. Do not use makeshift methods or material
which may compromise the installation. England’s will not be liable for consequential or indirect
damages to property or persons resulting from the use of this product.
Call (800-245-6489) and/or consult a professional installer if you have any questions.