ON/OFF
ON/OFF
R
Amp
Tube
FOOTPEDAL
Z-4
Options for controlling the ENGL 570 Preamp remotely:
3. Two-way footswitch (e.g. ENGL Z-4):
Connect two-way
footswitches to the amp by plugging a stereo ¼ " cord
into jack no. 59.
Functions: Ch.1 / Ch.2 (Main Channels) and
Sub Channel I/II Clean - Crunch and Lead I - Lead II.
This means you can't activate sub channels directly,
and must first switch to the other Main Channel.
As an alternative to a two-way footswitch, you can connect
a MIDI switcher (the ENGL Z-11 will do nicely) to this jack (59)
to control the two switching functions.
31
3.
1. MIDI foot board (for example, the ENGL Z-12 or ENGL Z-15 pictured above):
Connect
the foot board to the preamp using a standard 5-pin DIN cable. All 5 terminals of both
connectors must be wired in a 1:1 configuration: MIDI data transmission requires two wires,
and the ENGL MIDI foot board uses two more wires for purposes of power supply.
This combination affords access to all of the amp's 128 MIDI presets.
The Z-15 foot board also lets you control Master Volume Mute via MIDI controller.
2. ENGL Custom Z-9 Footswitch:
This special foot board connects to the preamp
via a ¼” stereo cord plugged into the Serial Amp Port (58) or via a 5-pin DIN cord
plugged into the MIDI IN port (55). The former option affords switching access
to channels and two special functions (for example,
Hi Gain
or
Mega Lo Punch
).
In the latter setup, the Z-9 serves as a MIDI foot board that accesses
the first 10 MIDI presets.
1.
1. 2.
or
1./2.
2. 3.
G
ROUND
L
IFT
SWITCH
GROUND
FLOATED
GROUND
INPUT
A
UXILIARY
SEND
FX L
OOP
RETURN
LEFT
RETURN
RIGHT
S
TEREO
O
UTPUT
LEFT
RIGHT
LEVEL
-20/0 dB
LEVEL
RIGHT
BALANCED
F
REQUENCY
C
OMPENSATED
L
INE
O
UTPUT
O
VERLOAD
G
ROUND
T
O
P
IN
1
G
ROUND
L
IFTED
LINE
OUT
GROUND
LEFT
BALANCED
STEREO
0 dB
<-
REPLACE FUSE
ONLY WITH SAME
TYPE AND RATING !
P
ROGRAMMABLE
S
TEREO
T
UBE
P
REAMP
T
YPE
E570
Designed by: Horst Langer
MADE IN GERMANY
R
DO NOT OPEN !
RISK OF ELECTRIC SHOCK !
DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE !
CAUTION !
!
F
OOTSWITCH
S
ERIAL
A
MP
C
ONTROL
P
ORT
MIDI
THRU
MIDI
IN
M
IDI
F
OOT-
CONTROLLER
C
H
1 / C
H
2
S
UB
I / II
M
IDI
C
HANNEL
& V
OL
. 0
CAUTION:
C
ONNECT
ENGL
C
USTOM
F
OOTSWITCH
Z-9 O
NLY
T
O
T
HE
S.A.C. P
ORT
!
THRESHOLD
MUTE
DEPTH
N
OISE
G
ATE
1 2 3 4 5 6
0
1
2
3
4
Down
5
6
7
8
9
Up
Bank or
MPN
MIDI Channel
Setup:
press Down & Up
simultaneously
until >c< appears
at the left;
select the
desired MIDI Channel
via Down or Up;
press 0 to store the setting
or press 9 to quit the Setup.
MIDI
Footcontroller
Z-15
Cn.1 Setup
Write
Linear Positve
Cn. value down
Linear Negative
Cn. value up
Log. Positive
Cn. initial value
Log. Negative
confirm MPN
Cn. S. I.10 ms
Switch Loop 1
Cn. S .I. 20 ms
Switch Loop 2
Cn. S. I. 30 ms
Switch Loop 3
Cn. S. I. 50 ms
Switch Loop 4
Cn.2 Setup
End
Internal Continuous
Controller:
Activate MIDI Program
Direct Access Mode;
press 1 or 2 to send
controller commands;
press 3 to switch between
controller default and
initial values.
MIDI Program
Bank Mode:
Active after power up;
Press Up & Down
to select bank 1 - 13;
press 0 to 9 to select
desired MIDI program
no. (MPN)
Controller 1 Setup for
Cont. Controller 1:
Press 0 in the
first bank (00x)
until >Cn.1< appears.
Changing settings:
Controller number:
Down or Up.
Controller curve:
1, 2, 3, 4.
Controller command
send interva:
5, 6, 7 8.
Press 0 to store.
MIDI Program
Direct Access Mode:
Press 0 in the
first bank (00x)
until >Cn.1< appears;
or
press 9 in the
last bank (12x)
until >Cn.2< appears,
then press 9;
press Down or Up to
select the desired MPN;
press 4 to confirm
selected MPN.
Amp
Technology
Tube
R
Power
Supply
7-12 Volts AC
9-15 Volts DC
300 mA
MIDI
Out
Cont.Controller 1
Input
Cont.Controller 2
< Input
Switch Loop
3 & 4
Switch Loop
1 & 2 >
Switch Loop Setup:
Activate MIDI Program
Direct Access Mode;
select the desired MPN,
press 4 to confirm;
set switch loop status
to on or off using
5, 6, 7, 8
for the respective loop.
Press 0 to store.
Controller Setup for
Cont. Controller 2:
Press 9 in the
last bank (12x)
until >Cn.2.< appears;
Changing settings:
Controller Number:
Down or Up.
Controller curve:
1, 2, 3 4.
Controller command
send interval:
5, 6, 7, 8.
Press 0 to store.
Switch
Loop 1
Switch
Loop 2
Switch
Loop 3
Switch
Loop 4
R
Amp
Technology
Tube
Custom
Footswitch
Z-9
S.A.C.:
Channel 1
S.A.C.:
Channel 2
S.A.C.:
Channel 3
S.A.C.:
Channel 4
S.A.C.:
Function 1
S.A.C.:
Function 2
MIDI:
Patch 1/6
MIDI:
Patch 2/7
MIDI:
Patch 3/8
MIDI:
Patch 4/9
MIDI:
Patch 5/10
MIDI:
Bank A/B
Power Supply
7-14 Volts AC
9-20 Volts DC
approx. 100 mA
MIDI
Out
Serial Amp
Control Out
Caution !
Connect To
Amplifier
Only!
Design by
Horst Langer
Setting up functions:
To assign amp switching
options to Function
buttons 1 and 2,
press Channel 1 and
the desired Function
button simultaneously
until the LED flashes.
Confirm by pressing the
target Function button.
Press Channel 1, 2, 3, 4
buttons (once or twice)
to select the desired
switching feature.
Press the other
Function button for
about one second
to store.
Alternative
Power Supply
refer to the
Operator's Manual