* The amp does not power-up after you have switched the power on; the Power On LED (12) 
   does not light up; the Channel & Mid Shape switching functions do not react, 
   i.e. the corresponding control LED's do not indicate an active function; 
   moreover no sound is emanating from the connected speaker. 

-> Is the mains cord connected to the receptacle/live power source?  
-> Is the power cable you are using intact? Try another equal mains cable.   
-> Is the mains lead properly connected to the AC Power Inlet (15) at the amp?  
-> Possibly the mains fuse (16) has blown, unplug the mains cord from the mains connector   
    and the receptacle and check the mains fuse.  

* The amp fails to respond when you try to control switching functions remotely 
   using a footboard such as the Z-4 or a MIDI switcher such as the ENGL Z11-S.A.C..

-> Are the footpedals (or the switching loops) connected to the corresponding 
    footswitch jacks (17, 18)?
-> Are the cords you are using stereo, intact, and wired properly?
    (Refer to "Wiring of Principal Connectors" for pin assignments.)
-> If you are using footswitches other than an ENGL Z-4 or Z11-S.A.C., are the switches or relays 
    inside the boards or switching loop systems off/on Single Pole Single Throw (SPST) switches?
    In other words, do these switches continuously connect to GND when you wish to activate 
    the given function? 
    If you're unsure about the answers to these questions, consult an authorized service center
    or a professional specialist.

* The amp is not providing an output signal/no sound is emanating 
   from the speaker.

-> Is at least one speaker connected to the speaker outputs "A" (22) or "C" (24)?
-> Is the power amp activated (Standby switch to ON/"upper" position)?
-> Are all cords (guitar, effect, and speaker) connected properly and are they functional?
-> Unplug connected effectors and see if the amp works fine without these peripheral devices.
-> Is the 

Power Soak Selector

 (step switch; 25) set to "Speaker Off? "

    In this case, the Output "C" (24) is switched off!
    Set the 

Power Soak Selector

 (25) to another position, e.g. "Full Power."

-> Are the Master, Gain or Volume knobs set to a value greater than "0" 
    (in fully counter-clockwise position)? 
    If any of these knobs is fully down, no signal is routed to the amp's outputs.
-> You may be looking at a faulty tube or another defect. (the internal power tube fuses blown, etc.)
    In this case, be sure to take the amp to an authorized, professional service center.

* The speaker is emitting humming noises:

-> Is there a connection (for example, via a shielded circuit, e.g. Line Out) between the amp
    and another device that is grounded via a power plug of its own? 
    Two or more circuits sharing a common electrical ground line can cause audible hum. 
    If low-frequency noise is emanating from your rig, be sure to consult a specialist.
-> The amp and mains grounds are not connected properly or are altogether 
    disconnected. Have an experienced specialist check this.
-> Cords connected to the input or effect loops may not be shielded properly. 
    Replace them to check if this is indeed the case.
-> The amp or speaker cords may be picking up interference from powerful 
    magnetic fields (for example, of nearby power transformers or electrical motors). 
    Reposition the amp and connector cables.
-> The amp or speaker cords may be picking up radio signals, for example, 
    from activated mobile telephones or powerful local transmitting stations nearby. 
    Switch off mobile phones while troubleshooting noise problems.

* One of the power amp's internal micro-fuses blows, so its output power 
   and therefore the overall volume drops dramatically:

-> The given power tube may be defective. If that power tube's internal micro-fuse is replaced 
    and the new fuse also blows, the defective tube needs to be swapped out. Fuses and tubes 
    should be checked and replaced by a qualified professional or specialist.
 -> Other reasons a power amp fuse may blow: The amp has been overloaded by excessive volume 
    levels, mains voltage, or the wrong output impedance. Check the speakers' overall impedance and, 
    if necessary, adjust your setup accordingly (refer to the paragraph under
    "Speaker/cabinet options" in section 24).

CAUTION! Please read and heed the following:

You'll find an ancillary pamphlet accompanying this owner's manual entitled
Instructions for the Prevention of Fire, Electrical Shock and Injury.
Be sure to read it before you plug in and power up the amp!

Содержание Metalmaster 20 E304

Страница 1: ...E304 E309 Metalmaster 20 Operator s Manual...

Страница 2: ...amp is preceded by NOTE or CAUTION Please pay particular attention to these safety tips The ENGL team wishes you all the best may you and your amp enjoy a harmonically rich future together Front 1 Inp...

Страница 3: ...gree Mid Scoop Metal Master amp The LED above the button lights up to indicate Mid Shape Mid Boost or Mid Scoop is activated The Mid Shape Mid Boost or Mid Scoop sound feature may also be switched usi...

Страница 4: ...may be equipped with LEDs indicating the given switching status Each of the two switches is provided with about 10 milliamperes current which suffices to power a standard LED The jack s mono terminal...

Страница 5: ...r one application for only when you are driving a combination of two 8 ohm cabinets speakers This output may only be used when an 8 ohm speaker or cabinet is connected to Output A jack 24 A typical ap...

Страница 6: ...around the back of the amp Do not operate the amp at peak loads that is with the Master knob set to position 5 or beyond pushing the power amp hard into overdrive for longer periods with the Power So...

Страница 7: ...D approx 16 5 x 7 9 9 x 9 Weight Combo approx 13 3 kg E302 approx 14 2 kg E304 approx 29 3 lb E302 approx 31 3 lb E304 Head approx 8 9 kg E307 approx 9 2 kg E309 approx 19 6 lb E307 approx 20 3 lb E30...

Страница 8: ...nstead Never use solvents they can dissolve the surface varnish and the front and rear panel labels Keep liquids well away from the amp particularly the interior of the housing Make sure air can circu...

Страница 9: ...a value greater than 0 in fully counter clockwise position If any of these knobs is fully down no signal is routed to the amp s outputs You may be looking at a faulty tube or another defect the intern...

Страница 10: ...com or www engl amps de Text design graphics and layout by Horst Langer ENGL Amp Designer Stereo 1 4 jack tip refer to 3 ring refer to 2 sleeve Ground Shield Use a stereo plug only Stereo 1 4 TRS plu...

Страница 11: ...Notes Notizen...

Страница 12: ...www engl amps com...

Отзывы: