background image

Table of Contents

page

Introduction
Features and Functionality at a Glance
Contents
Front Panel Features:

Rear Panel Features:

Troubleshooting
Technical Data
Tube Map, Tube Exchange Service
Wiring of Principal Connectors

Note:

:

Handling and Care

Input; Clean (Gain), Bright, Lead (Gain)
EQ section: Bass, Middle, Treble, Shape (Contour)
Lead Control Features: Lead Presence, Lead Volume
Channel selection Clean/Lead, Gain Low/High

Stand By, Power

Poweramp Output 4, 8, 16 Ohms
Poweramp Output: Cabinet options

Power Amp section: Master A/B

Mains, Mains Fuse
S.A.C. Port for Z-9 or Z11-S.A.C., Footswitch Ports

You'll find an ancillary pamphlet accompanying this owner's manual entitled
Instructions for the Prevention of Fire, Electrical Shock and Injury.
Be sure to read it before you plug in and power up the amp!

Technical specifications are subject to change without notice.

Noise Gate: Threshold Level
FX Loop: Send, Return, and Balance

Remote Control Options
Configuration table for Z-9 settings

CAUTION! Please read and heed the following:

4
5
6

6, 7
7, 8
8
8, 9
9, 10
10

10, 11
11, 12
13
14
14
15

15, 16
16, 17
18
19
20
21
22

3

Содержание Artist Edition E651

Страница 1: ...E650 E651 E653 Ritchie Blackmore Artist Edt Operator s Manual...

Страница 2: ...Loop off on Noise Gate S A C Port FX Loop Send Return Balance Dry Effect Threshold Off Lo Hi Noise Gate Lead Channel 100 Watts All tube Guitar Amp Head Ritchie Blackmore Signature TYPE E650 Artist Ed...

Страница 3: ...16 Ohms Poweramp Output Cabinet options Power Amp section Master A B Mains Mains Fuse S A C Port for Z 9 or Z11 S A C Footswitch Ports You ll find an ancillary pamphlet accompanying this owner s manu...

Страница 4: ...es and applications There are few more handy features to rave about This amp sports our Serial Amp Control Port or S A C Port for short for connecting remote control units like the ENGL Z 9 Plug an EN...

Страница 5: ...e for the Clean channel and the Shape Contour button in the EQ section for and You can footswitch these knobs to activate two different power amp volume settings on the fly without twisting a knob It...

Страница 6: ...ation due to high frequency loss use the shortest cords feasible as a rule the shorter the cord the less susceptible it is to high frequency attenuation Gain control for the tube amp s extraordinary v...

Страница 7: ...knob settings beyond the 1 o clock s position at high output power in order to prevent interaction between guitar and speakers that possibly causes undesirable feedback Moreover the noise floor rises...

Страница 8: ...e may also be switched using a Z 9 Custom Footswitch connected to the S A C Port 19 or a footswitch connected to jack 21 The button 8 on the amp s front panel is disengaged when you switch the Shape C...

Страница 9: ...wer amp output The green LED to the right of the knob lights up to indicate Master B is enabled and determining the master level The Master B knob is selected whenever you activate via button 11 and n...

Страница 10: ...onsiderable wear The amp is ready to run when you flip the Standby switch because the tubes are already warm and don t require time to heat up For breaks of 20 minutes and longer I recommend that you...

Страница 11: ...ther clever switching concept it features four switches that afford you direct access to and in combination with the two Gain stages and Clean Low Gain Clean High Gain Lead Low Gain and Lead High Gain...

Страница 12: ...conventional footswitch with two switching functions for example the ENGL Z 4 2 x off on Single Pole Single Throw or SPST for short This type of footswitch lets you access One of the two switches acti...

Страница 13: ...keep a lid on extraneous noise during short breaks It s in the nature of high gain rigs to generate undesirable peripheral noise in overdriven high gain channels This is attributable to the physical...

Страница 14: ...p signal is routed through with no processed signal 0 wet balance added to the mix Twist the knob clockwise to blend in the processed signal parallel passive wet balance 1 99 depending on knob positio...

Страница 15: ...ol down before you transport it Ten minutes or so will spare the tubes Tubes take some 20 seconds to warm up after you switch the power on and about two to three minutes before they are able to pump o...

Страница 16: ...ply switch the amp off and on again If a reset doesn t solve the problem there is a defect in the control system probably on the logic board holding the microcontroller or merely a faulty contact on o...

Страница 17: ...efect In this case be sure to take the preamp to an authorized professional service center Is there a connection for example via a shielded circuit between the amp and another device that is grounded...

Страница 18: ...ly to 4 8 and 16 ohms T slo blo M medium blo ECC83 F Q input tube EL34 E651 6L6GC E650 2 matched sets Replace tubes with selected sets only Refer to page 20 for pin assignments Replace these with fuse...

Страница 19: ...d on _ _ _ _ _ _ _ 20 _ _ _ Replaced by _ _ _ _ _ _ _ _ _ _ _ _ _ _ Replaced tubes _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Reason _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 20: ...gh Gain via jack via jack 22 A switch connected to this terminal T controls FX Loop off bypassed on enabled via jack 20 Master A B Master A control Master B control via jack 21 Clean Lead Clean channe...

Страница 21: ...tch The ENGL Z 4 dual footswitch 1 2 2 2 Serial Amp Control Port CAUTION Connect Custom Footswitch Z 9 Only Clean Lead Gain Low High Footswitch Master A B Mid Shape Contour FX Loop off on Noise Gate S...

Страница 22: ...rently or newly selected configuration For example if LED 3 flashes when the Z 9 s Setup routine is activated then the Artist Edition R B S Amp s switching feature is currently assigned to the corresp...

Страница 23: ...Space for User Notes 23...

Страница 24: ...www engl amps com...

Отзывы: