MCF-LW06010 is available with DIN rail option (MCF-DIN105):

2. Overview

2.1 Technical data

CPU Cortex M4
RTC
EEProm 32KB
Flash 1MB
Encryption AES 128 bit
LiPo 800mAh rechargeable battery
Class C LoRaWAN® stack EU868, AS923, AU915, US915
1000Vdc isolated analog inputs

Содержание MCF-LW06010

Страница 1: ...3 3 1 Connection 3 3 2 Analog inputs 4 3 3 Con guration 5 3 4 System led 6 3 5 Firmware update 7 4 Setup 7 4 1 Period 7 4 2 Thresholds 8 4 3 Other settings 9 5 Diagnostic 10 6 LoRaWAN network 10 6 1 A...

Страница 2: ...Last update 2022 02 16 09 14 manual_mcf lw06010 http www enginko com support doku php id manual_mcf lw06010 http www enginko com support Printed on 2022 02 16 09 16...

Страница 3: ...he European Parliament on waste electrical and electronic equipment WEEE and pursuant to and in accordance with Article 20 of the Directive 2013 56 EU of the European Parliament on batteries and accum...

Страница 4: ...www enginko com support Printed on 2022 02 16 09 16 MCF LW06010 is available with DIN rail option MCF DIN105 2 Overview 2 1 Technical data CPU Cortex M4 RTC EEProm 32KB Flash 1MB Encryption AES 128 b...

Страница 5: ...wer supply 10 36Vdc Storage temperature range 20 C 80 C Working temperature range 10 C 70 C Dimensions L x H X P 81 x 60 x 50mm 3 Installation 3 1 Connection 3 1 1 Power connection as stand alone devi...

Страница 6: ...e 10 36Vdc J2 2 GND Negative power supply Power can also be supplied by USB 3 1 3 Antenna The magnetic antenna must be positioned on a metal body It should preferably be vertical and at least 30 cm aw...

Страница 7: ...maximum value 12V Max error 0 1 Insulation 1000Vdc Caution inputs are not galvanically isolated from each other 3 3 Con guration To deploy the sensor use LoRaWEB online tool to setup LoRaWAN credenti...

Страница 8: ...lw06010 http www enginko com support doku php id manual_mcf lw06010 http www enginko com support Printed on 2022 02 16 09 16 3 4 System led LoRaWAN not con gured Slow ashing Joining Quick ashing Send...

Страница 9: ...ion error Flashing 1 second 3 5 Firmware update Save the new rmware le exe on the PC run the le select the USB FW port and start the update and waiting for the end message 4 Setup 4 1 Period Period is...

Страница 10: ...16 09 16 Period interval can be set with LoRaWEB or with downlink command 4 2 Thresholds On the MCF LW06010 is possible to set 4 thresholds for each channel Th Threshold High Rising Th Threshold High...

Страница 11: ...ds a new uplink with the latest measure Thresholds can be enabled disabled and changed va USB with LoRaWEB or with downlinks 4 3 Other settings DST set to change DST default none Time sync uplink set...

Страница 12: ...tra c on the network Please check chapter 2 1 DATA FRAME FORMAT Con rmed Uplinks set for uncon rmed uplinks default con rmed uplink Single join day set for to allow only one join per day default multi...

Страница 13: ...ations on a LoRaWAN network NONE sensor not activated 1 OTAA the JoinEUI and the AppKey not setted must be written to the device 2 OTAA MCF88 Over the air activation xed keys JoinEUI 904e915000000002...

Страница 14: ...Network settings please keep Any settings Change it only if Objenious network is used default_ any Network type LoRa syncword can be setted as private 0x12 instead public 0x34 but the NS must be sette...

Страница 15: ...be requested to enginko please provide the DevEUI of the sensor when you ask for that code 8 General con guration le WIth LoRaWEB is possible to con gure the device using an XML le instead to manually...

Страница 16: ...l be applied to all the sensors With an additional XLS le is possible to load di erent LoRa con guration parameters Activation Type AppKey AppEUI NetKey DevAddress Band Private option for each sensor...

Страница 17: ...device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to...

Страница 18: ...expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Contains FCC ID 2AWAL409810 13 Contacts enginko Srl Via Roma 3 I 28060 Sozzago NO T...

Отзывы: