Engineered air TriMed GH Series Скачать руководство пользователя страница 5

P

 

   

GH Manual

 

IOM-62 

5 of 9 

Nov 17 R1 

 
PARTS 

Contact the nearest Engineered Air sales office or factory for replacement parts.  Be sure to include 
Model Number, Serial Number, date of installation, the nature of the failure and the description of the 
part(s) required.  Some parts may not be stocked items and must be manufactured or ordered. 

RECEIVING 

Refer to the back of the packing slip for receiving instructions. 
On receipt of the unit, check for damage.  Inspect protective covers for punctures or other signs that 
there may be internal damage.  Remove protective covers and check for internal damage.  Replace 
covers if the unit is not being installed at this time.  Open access doors and check for internal damage.  
Close access doors when inspection is complete. 
All units are pre-tested at the factory immediately prior to shipping and are ensured to be in good 
operating condition at that time.  If damage is found, refer to the instructions on the back of packing 
slip. 
On receipt of the unit, check the electrical characteristics (see rating plate) to make sure that the 
electrical supply matches.  All parts for field installation are listed on the shipping order form. 
 

TEMPORARY STORAGE 

If a unit is to be stored prior to installation the following precautions are required: 

 

Store in a well drained area that will not accumulate surface water. 

 

Store in an area where the unit will not be damaged. 

 

All protective coverings that were provided for shipping must be in place. 

 

Protect indoor mounted equipment from rain and snow. 

INSTALLATION 

Warning: 

This unit is not explosion proof.  It is not suitable for hazardous locations as defined 
by the National Electrical Code of the Canadian Electrical Code.  

 

Warning: 

All wiring and piping installation must be completed by qualified technicians in 
accordance with all federal, state, provincial and/or local codes.

 

Note: Installation shall be in accordance with this manual and all other associated component and 
control Installation, Operation and Maintenance Manuals. 
 

Содержание TriMed GH Series

Страница 1: ...STINGS CRES SE CALGARY ALBERTA T2G 4C8 Ph 403 287 2590 Fx 888 364 2727 32050 W 83 rd STREET DESOTO KANSAS 66018 Ph 913 583 3181 Fx 913 583 1406 1175 TWINNEY DRIVE NEWMARKET ONTARIO L3Y 5V7 Ph 905 898 1114 Fx 905 898 7244 SALES OFFICES ACROSS CANADA AND USA Retain instructions with unit and maintain in a legible condition Please give model number and serial number when contacting factory for inform...

Страница 2: ... 3 Warranty 4 Parts 5 Receiving 5 Temporary Storage 5 Installation 5 Codes 6 In Canada 6 In Usa 6 Assembly Drawing 6 Electrical Connections 7 Before Starting 7 Maintenance 7 Maintenance Schedule 7 Electrical 8 Corona Plates 8 Corona Plate Inspection 8 Troubleshooting Chart 9 Airtex Manufacturing LLLP All rights reserved ...

Страница 3: ...nt The submittal record is considered to be part of the Installation Operation and Maintenance Manual SAFETY PRECAUTIONS Read understand and follow the complete manual before beginning the installation including all safety precautions and warnings Warning This unit contains high voltage circuits Electrical shock or death could occur if instructions are not followed This equipment contains moving p...

Страница 4: ...o accident misuse or unauthorized alterations or where TRI MED s installation and service requirements have not been met The foregoing warranty is in lieu of all other warranties express or implied TRI MED specifically disclaims any implied warranty of merchantability and or fitness for purpose Under no circumstances shall TRI MED be liable to nor be required to indemnify Buyer or any third partie...

Страница 5: ... is found refer to the instructions on the back of packing slip On receipt of the unit check the electrical characteristics see rating plate to make sure that the electrical supply matches All parts for field installation are listed on the shipping order form TEMPORARY STORAGE If a unit is to be stored prior to installation the following precautions are required Store in a well drained area that w...

Страница 6: ...hall be in accordance with all other National Provincial and Local Codes and in accordance with the local authorities having jurisdiction In USA 1 The installation of this unit shall be in accordance with the latest edition of the National Electrical Code ANSI NFPA 70 State and Local Codes and in accordance with the local authorities having jurisdiction 2 This unit shall be electrically grounded i...

Страница 7: ...g DO NOT bypass any interlock or safety switches under any circumstances m c The effectiveness of the GH generator head is a function of its ability to convert oxygen O2 to ozone O3 through high voltage corona plates It is essential to maintain airflow through clean corona plates Dirty filters will not only reduce the oxygen across the corona plates but also can change the air balance To provide a...

Страница 8: ...o sets Clean the dirty corona plates by using a dishwasher or hand wash If cleaning by hand begin cleaning the plates by spraying or dipping them in cleaning solution The cleaning solution should be a detergent product that is capable of breaking down oils and greases but leaves no residue when rinsed off If the plates are rinsed in hard water then clean compressed air should be used to dry off of...

Страница 9: ...izer Output control higher Energize additional generator heads Verify air flow balance across head assembly Corona plates dirty Clean corona plates See Plate Cleaning on page 8 No voltage at plates after cleaning Inspect for plate damage and replace damaged plate Defective transformer Check primary and secondary voltages and replace if required Clean Plate Dirty Plate Broken Plate ...

Отзывы: