background image

1   Introduction

1. Introduction

1.1. General

This user manual contain important information about your product's functions and

characteristics, and how to use it in the best way. Before you begin using the product, it is

important that you read and understand the content of these instructions, especially the

sections that address safety.
In addition to these instructions, you must study and understand the applicable safety

information for the relevant base machine as well as any other equipment involved.
The user manual is supplied with supplementary documentation providing more detailed

descriptions of the installation, fitting, operation and maintenance of control systems and

custom modifications for your specific product.
Information, images, illustrations and specifications used in the instructions are based

on product information that was available at the time of going to press. Images and

illustrations used in the instructions are typical examples and not intended to be exact

depictions of various part of the product. We reserve the right to make changes without

prior notice.
Always store the user manual together with any other supplementary information in a safe

manner and such that it is always available.

1.2. Scrapping and recycling

engcon makes constant efforts to reduce its environmental impact. engcon's products

comprise at least 99 per cent recyclable material. All assembly and service work must

take place in compliance with legislation and ordinances governing the environment,

health and occupational safety. This refers to all work with residual materials including

handling, storage and processing. To prevent contamination of soil and water, spillages

must be avoided. Should a spillage occur, it must be dealt with.
Hazardous waste may only be disposed of by those authorized to do so. All waste

produced must be disposed of in compliance with applicable legislation and ordinances:
- Metal and plastics to be recycled.
- Hydraulic hoses are normally used for energy recovery (sort as hazardous waste).
- Oils and greases are normally used for energy recovery (sort as hazardous waste).
- Electronic components to be recycled for materials (sort as hazardous waste).
- Packaging to be sorted at source and recycled for materials.
- Paper to be sorted at source and recycled for materials.
If in doubt, contact the environmental manager at engcon.

1.3. Technical support and spare parts

Contact information for support and spare parts can be found at www.engcon.com.

4

Содержание 9000225

Страница 1: ...User manual Constant flow Article 9000225 Language Country Original Instructions...

Страница 2: ...he market leader in tiltrotators and tools for excavators We represent innovation knowledge and experience and we develop our products with a focus on the customer s needs Please visit our website for...

Страница 3: ...crapping and recycling 4 1 3 Technical support and spare parts 4 1 4 Product approval 5 1 4 1 Declaration of Incorporation 5 2 Safety 2 1 General 6 3 Operation 3 1 Programming sequence 9 3 2 Activatio...

Страница 4: ...ny other supplementary information in a safe manner and such that it is always available 1 2 Scrapping and recycling engcon makes constant efforts to reduce its environmental impact engcon s products...

Страница 5: ...rds Designation SS EN ISO 13849 1 2008 Safety of machinery Safety related parts of control systems Part 1 General principles for design SS EN ISO 12100 2010 Safety of machinery General principles for...

Страница 6: ...hem The following warning levels are used in this user manual DANGER Indicates that an accident will occur if the regulation is not followed Risk of personal injury or death WARNING Indicates that an...

Страница 7: ...are determined in the programming sequence 2 Activation sequence the activation sequence starts constant flow to selected functions 3 Deactivation when constant flow is deactivated all active functio...

Страница 8: ...3 Operation IMPORTANT Maintenance and repair of the electrical system may only be carried out by professionally qualified persons 8...

Страница 9: ...grammed to a roller and button EXTRA 2 2146492 2 Press the constant flow button after 3 seconds a buzzer will sound in the DC2 cabin module Release the function roller button Speed and direction are l...

Страница 10: ...elected functions are activated with the programmed speed and direction 2147270 2 After 3 seconds a buzzer will sound in the DC2 cabin module If the operator releases the button within 2 seconds after...

Страница 11: ...sed within 2 seconds the constant flow function will start and the activation sequence must then be restarted WARNING Beware of moving parts A lack of awareness may lead to crush injuries Risk of pers...

Страница 12: ...3 Operation The constant flow button is depressed The safety gate is opened Faulty constant flow button 12...

Страница 13: ...cabin module the selected function will stop working Activation interval exceeded During the activation system the constant flow button must be released within 2 seconds Nothing happens when a constan...

Страница 14: ...Notes...

Страница 15: ...Version 1 3 engcon North America Inc 2666 State St 9 Hamden CT 06517 Phone 1 203 691 5920 northamerica engcon com www engcon com...

Отзывы: