IP
•
Tube E
2
Duo
Engage Communication Inc.
converter as DB9 serial ports are not common on todays computers. In this case, use the NULL
MODEM ADAPTER provided to allow communication between IP
•
Tube E
2
Duo and computer.
The use of the null modem adapter is necessary when using two USB to DB9 serial converter cables.
Communication to the console port should be set for:
115200 baud, 1 stop bit, no parity, 8 bit fixed, flow control none
Once a serial connection between a workstation and IP
•
Tube E
2
Duo console port is established
and a carriage return
<
CR
>
is entered, a Login prompt will appear.
The default login is: root.
The default password for first time login is also
root
. It is highly recommended that the password
be changed upon initial login.
3.1.4
Configuring the Engage IP
•
Tube E
2
Duo for the LAN
IP
•
Tube E
2
Duo needs to be configured with a number of parameters for proper operation on the
network, including:
•
Ethernet IP address
•
IP data target unit IP address (peer ip address)
•
Default gateway if the IP data target is on another IP network
The configuration procedure depends on the network environment in which IP
•
Tube E
2
Duo is to
be installed.
Note: It is strongly suggested that you configure IP
•
Tube E
2
Duo with its unique network identity
before making any Ethernet or Wide Area connections.
3.1.5
Ethernet Interfaces
Engage IP
•
Tube E
2
Duo systems utilize 10/100/1000BaseT Ethernet cable to connect to the Local
Area Network. Each system provides a 10/100/1000BaseT interface on the front panel for connection
to an Ethernet switch or hub using a straight-thru Ethernet cable. For direct connection to a PC
or other LAN device, the user should obtain a 10/100/1000BaseT crossover cable.
10/100/1000BaseT Ethernet cabling and crossover pinouts are provided in the Appendices.
3.1.6
Ethernet Status LEDs
The green LED on the right side of the Ethernet interface indicates link established and it will blink
for activity.
The amber LED on the left side of the Ethernet interface indicates a 1000BaseT link established.
3
INSTALLATION OF IP
•
TUBE E
2
DUO