ENFORCER Power Supplies/Chargers 

SECO-LARM U.S.A., Inc. 

3

 

 

 

 

1.

 

Mount the PC board in the desired location or enclosure to be easily accessible for future servicing.  

2.

 

Set the DC power output voltage: 

a.

 

The ST-1206-1.5AQ is set at 12VDC by default. For 6VDC, cut the wire 
loop (see Wiring Diagram, pg. 2) and insulate the wire leads.  

b.

 

For ST-2406 series, set the desired DC output voltage (6, 12, or 
24VDC) of the power supply using the DIP switch as in Table 1 for 
ST-2406-3AQ, or Table 2 for all other ST-2406 series. 

IMPORTANT:

 Disconnect power before changing these DIP switch 

settings (Note the default voltage output setting is 12VDC). 

3.

 

Connect a transformer with appropriate specifications (See Table 3 below) 

Table 3: 

Output 

voltage 

ST-1206-1.5AQ 

ST-2406-2AQ 

ST-2406-3AQ 

ST-2406-5AQ 

ST-2406-7AQ 

ST-2406-10AQ 

6VDC 

12VAC/20VA 

12VAC/20VA 

ST-UV16-W50Q

 

16VAC/50VA 

ST-UV16-W100Q

 

16VAC/100VA 

ST-UVDA-W180Q

 

24~28VAC/180VA 

ST-UVDA-W180Q

 

24~28VAC/180VA 

12VDC 

ST-UV16-W50Q

 

16VAC/50VA 

ST-UV16-W50Q

 

16VAC/50VA 

ST-UVDA-W100Q

 

24~28VAC/100VA 

ST-UV16-W100Q

 

16VAC/100VA 

ST-UVDA-W180Q

 

24~28VAC/180VA 

ST-UVDA-W180Q

 

24~28VAC/180VA 

24VDC 

N/A 

ST-UV24-W50Q

 

24VAC/50VA 

ST-UVDA-W100Q

 

24~28VAC/100VA 

ST-UVDA-W180Q

 

24~28VAC/180VA 

24~28VAC/210VA 

28VAC/350VA 

4.

 

Connect the wires to their respective terminals (see "Wiring Diagram," pg. 2). 

Installation:  

Table 1 (ST-2406-3AQ): 

Voltage 

SW1 

SW2 

6V 

ON 

ON 

12V 

ON 

OFF 

24V 

OFF 

OFF 

 

1.

 

Before connecting any external devices, temporarily 
power up the unit and measure the DC output 
voltage at the device connection point to avoid 
damage to devices. If voltage drop is large, adjust 
the voltage using the output voltage trimpot (except 
ST-1206-1.5AQ, see Fig.1). Then disconnect power 
before connecting external devices. 

2.

 

See ST-2406 Series LED status indicators in Table 4. 

3.

 

The ST-1206-1.5AQ comes with a 3A fuse. The ST-2406-2AQ, ST-2406-3AQ, and ST-2406-5AQ models 
come with a 5A fuse. The ST-2406-7AQ and ST-2406-10AQ models come with a 10A fuse. Use only the 
correct fuses to prevent short circuits and damage to the power supplies/chargers or the alarm access 
control panel.

 

4.

 

The automatic low-battery cutoff will cut power when battery voltage drops below 20% of the set output 
voltage (ST-2406-3AQ only). 

Warning: 

1.

 

Installation and servicing must be performed by qualified service personnel.  

2.

 

The power supply must be installed in accordance with all national and local electrical codes. 

3.

 

Do not use a higher AC input than recommended (rated max. 28VAC). 

4.

 

DISCONNECT THE POWER SUPPLY BEFORE CHANGING THE DIP SWITCH SETTINGS OR 
PERFORMING ANY TYPE OF SERVICE. There are no user serviceable parts inside.  

5.

 

Do not touch any exposed metal parts, electrical, or electronic components as these parts may become 
very hot under load 

6.

 

DO NOT USE METAL SPACERS TO MOUNT THE POWER SUPPLY'S PC BOARD. 

7.

 

Connect these power supplies/chargers only to a rechargeable backup battery. Use of a non-rechargeable 
backup battery could result in damage to the power supply/charger or the alarm access control panel.  

Table 2 (other ST-2406 series): 

Voltage 

SW1 

SW2 

6V 

ON 

OFF 

12V 

OFF 

OFF 

24V 

OFF 

ON 

 

Notes:  

Table 4 (ST-2406 Series): 

Green LED  Red/Blue LED  Status 

ON 

ON 

Normal 

OFF 

ON 

No VAC input 

ON 

OFF 

No VDC output 

OFF 

OFF 

No VAC input and VDC output 

 

Fig. 1  

 

Output voltage  
trimpot  

Содержание ST-1206-1.5AQ

Страница 1: ...t in battery short circuit protection LEDs indicate power status Programmable DC voltage output Regulated and filtered output voltage Fused output for a regulated charge Includes foam tape and battery leads for easy installation ST 2406 3AQ Upgraded Features High efficiency at full load Heat sink free design Low battery cutoff ST 2406 3AQ shown Features ...

Страница 2: ...3x35mm 33 4 x27 8 x19 16 95x73x40mm 51 2 x51 8 x23 16 140x130x55mm Specifications SECO LARM s ST series of power supplies chargers ensure that alarm systems and access control systems have enough power to do their job Protected by fused outputs input polarity protection diodes and backup battery polarity reverse protection these power supplies chargers can be used to maximize the security and effi...

Страница 3: ...id damage to devices If voltage drop is large adjust the voltage using the output voltage trimpot except ST 1206 1 5AQ see Fig 1 Then disconnect power before connecting external devices 2 See ST 2406 Series LED status indicators in Table 4 3 The ST 1206 1 5AQ comes with a 3A fuse The ST 2406 2AQ ST 2406 3AQ and ST 2406 5AQ models come with a 5A fuse The ST 2406 7AQ and ST 2406 10AQ models come wit...

Страница 4: ...r any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to the replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal ...

Отзывы: