background image

 

®

 

No Touch Request-To-Exit Sensor 

 

 

2

 

SECO-LARM

 

 U.S.A., Inc

 

Features:

 

 

Adjustable sensor range up to 7" (18cm). 

 

Weather resistant for outdoor use. 

 

Stainless steel plate.  

 

1A relay, adjustable trigger duration 0.8~30 
seconds or toggle. 

 

LED illuminated sensor area for easy 
identification.  

 

Selectable LED colors (turns from red to 
green or green to red) to show sensor 
activated.

 

 

Overview: 

 

 

  

 

 

 

 

Specifications: 

Power 

12~24 VDC 

Current 
drain 

(max.)

 

Standby 

16mA@12VDC / 25mA@24VDC 

Triggered 

25mA@12VDC / 32mA@24VDC 

Relay type 

Form C dry contact, 1A@30VDC 

Response time 

10ms 

LEDs 

Standby 

Red

2

 

Triggered 

Green

2

 

Output time 

0.8~30 s, toggle 

Range 

2”~7” (5~18 cm) 

IP rating 

IP65

3

 

Temperature range 

-4°~131° F (-20°~55° C) 

Weight 

Single Gang 

108g 

Single Gang 

w/ Mechanical Override

 

125g 

Slimline 

61g 

Slimline 

w/ Mechanical Override

 

77g 

European Plate 

77g 

  

2

Color function reversible 

3

Front panel only. 

1

1

/

2

” 

 

(39mm)

 

2

3

/

4

” 

 

(70mm)

 

Sensor range adjustment 

Trigger time adjustment 

LED control jumper 

5-pin connector 

Form C Mechanical override

1

 

4

1

/

2

” 

 

(115mm)

 

1

SD-9163-KSVQ and SD-9263-KSVQ 

only 

SD-9263-KSVQ shown

 

2

3

/

4

” 

 

(70mm)

 

4

1

/

2

” 

 

(115mm)

 

86mm

 

86mm

 

European Plate

 

ENFORCER

 

®

 

No Touch Request-To-Exit Sensor

 

 

 

 

SECO-LARM

 

 U.S.A., Inc

 

 

Wiring Diagram: 

 

 

Installation: 

1.

 

Run four wires through the wall to a single-gang or slimline back-box. 

2.

 

Connect the four wires from the back-box to the Request-to-Exit 
Sensor according the 

Wiring Diagram

 above. 

3.

 

Screw the plate into the back-box, taking care not to crimp the wires. 

4.

 

Remove clear protective film from the sensor before use. 

WARNING:

 Do not connect any device that will exceed 1A@30VDC. 

Changing the LED Color Jumper Placement: 

Slimline Models 

Single-Gang Models 

 

Adjusting the sensor range and trigger time: 

1.

 

The sensor range can be adjusted from 2”~7” (5~18 cm). 

2.

 

The trigger time can be adjusted from 0.8 to 30 seconds or toggle

4

.

 

NOTE: 

Do not force the adjustment trimpots to turn. Only minimal 

force is needed. 

 

 

 

Standby: Green 
Trigger: Red 

Standby: Red 
Trigger: Green 

(default) 

Place here for: 
Standby: Green
Trigger: Red 

Place here for:
Standby: Red 
Trigger: Green

(default)

 

Red Wire: +12~24 VDC

 

Brown Wire: Ground (-)

 

Blue Wire: COM

Purple Wire: N.O.

Green Wire: N.C.

Red Wire: +12~24 VDC

 

Brown Wire: Ground (-)

 

Blue Wire: COM

 

Purple Wire: N.O.

 

Green Wire: N.C.

 

Slimline models 

Single gang models 

Wiring for No Touch Sensor 

(SD-9263-KSQ shown) 

Wiring for No Touch Sensor 

with Form C Mechanical Override Button

  

(SD-9263-KSVQ shown) 

Sensor range 

adjustment 

Trigger time 

adjustment 

4

Set trigger time to maximum 

Trigger time: 0.8~30 seconds, toggle

4

 

Default: 0.8 seconds   

4

Toggle: turn all the way clockwise 

Sensor range: 2”~7” (5~18 cm) 

Default: 7” (18cm) 

Отзывы: