The ENFORCER IP Surge Protector is a passive device that helps protect sensitive networking
equipment from power surges. The device can be deployed in new installations or added to
existing ones.
The IPV-PD88Q IP Surge Protector should be installed between devices connected by Cat5e/6
4-pair UTP cable to protect against surges that could damage computer or video equipment.
NOTE
: For the best protection, installing two surge protectors is recommended: one at each end of
the network cable.
Bandwidth
Up to 1GHz
Maximum input
7.6Vp-p
Insertion loss
<0.2dB
Return loss
16dB@100Ω
Frequency response
Up to 3dB@113MHz
Insulation resistance
10,000MΩ
Maximum surge voltage
4 kV
Discharging current
100A
Surge life
300 surges@100A
Surge protection time
1ns
Surge resistance
0Ω
Signal passing
capability
Breakdown voltage
7.6V
Clamping voltage
10.0V
Connector
In
RJ45
Out
RJ45
Impedance
42
Ω
Dimensions
3
7
/
16
”x2
5
/
8
”x1
1
/
16
” (87x67x27 mm)
Weight
4.4-oz (126g)
Material
Aluminum
Operating temperature
-40°~194° F (-40°~90° C)
Unprotected End
Protected End
Top View
3
7
/
16
”
(87mm)
2
5
/
8
” (67mm)
2
5
/
8
” (67mm)
Mounting
Tab
To
Cat5e/6
Cable
To Protected
Device
Ground
1
1
/
16
”
(27mm)
ENFORCER
IP
Surge
Protector
SECO-LARM U.S.A., Inc.
3
1x IP Surge Protector
4x Mounting Screws
1x 12” (305mm) Ground Cable
4x Plastic Wall Anchors
Protecting Multiple Devices:
1.
Mount the IP Surge Protector as close as possible to the device to be protected.
2.
Detach the Cat5e/6 cable from the device to be protected and attach to the “Unprotected” port
of the IP Surge Protector.
3.
Attach an additional short Cat5e/6 cable between the device to be protected and the
“Protected” port of the IP Surge Protector. This cable should be as short as possible to connect
the two devices. In addition the protected cables should not cross unprotected cables.
4.
Use supplied ground cable to connect the ground (GND) terminal to earth ground. The system
should use a single ground point and the protected device should be isolated from ground.
Protecting a Single Device:
Installation:
NOTE
: These instructions assume that 2 IP devices have already been connected together.
Parts List:
Shortest
Possible
Cat5e/6 cable
Shortest
Possible
Cat5e/6 cable
Protected
End
Protected
End
IP Switch
(Protected)
IP Surge
Protector
Unprotected
End
To ground
Original Cat5e/6 cable
To ground
IP Surge
Protector
IP Camera
(Protected)
Unprotected End
Shortest
Possible
Cat5e/6 cable
IP Surge
Protector
To ground
IP Switch
(Not Protected)
IP Camera
(Protected)
Cat5e/6 cable
Protected End
1.
Mount the two IP Surge Protectors as close as possible to each device to be protected.
2.
Detach the Cat5e/6 cable from each device to be protected (such as an IP switch or IP camera)
and attach to the “Unprotected” port on its respective IP Surge Protector.
3.
Using additional short Cat5e/6 cables, connect each device to be protected to the “Protected”
end of its respective IP Surge Protector. These cables should be as short as possible to
connect each device to its respective surge protector. In addition the protected cables should
not cross unprotected cables.
4.
Use supplied ground cable to connect each IP Surge Protector’s ground (GND) terminal to
earth ground. The system should use a single ground point and the protected device should be
isolated from ground.