ENFORCER

 

IP

 

Surge

 

Protector

 

2

 

SECO-LARM U.S.A., Inc. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overview: 

Specifications: 

Introduction: 

The ENFORCER IP Surge Protector is a passive device that helps protect sensitive networking 
equipment from power surges.  The device can be deployed in new installations or added to 
existing ones. 

The IPV-PD88Q IP Surge Protector should be installed between devices connected by Cat5e/6 
4-pair UTP cable to protect against surges that could damage computer or video equipment. 

NOTE

: For the best protection, installing two surge protectors is recommended: one at each end of 

the network cable. 

Bandwidth 

Up to 1GHz 

Maximum input 

7.6Vp-p 

Insertion loss 

<0.2dB 

Return loss 

16dB@100Ω 

Frequency response 

Up to 3dB@113MHz 

Insulation resistance 

10,000MΩ 

Maximum surge voltage 

4 kV 

Discharging current 

100A 

Surge life 

300 surges@100A 

Surge protection time 

1ns 

Surge resistance 

0Ω 

Signal passing 
capability 

Breakdown voltage 

7.6V 

Clamping voltage 

10.0V 

Connector 

In 

RJ45 

Out 

RJ45 

Impedance 

42

Ω 

Dimensions 

3

7

/

16

”x2

5

/

8

”x1

1

/

16

” (87x67x27 mm) 

Weight 

4.4-oz (126g) 

Material 

Aluminum 

Operating temperature 

-40°~194° F (-40°~90° C) 

 

Unprotected End 

Protected End 

Top View 

3

7

/

16

” 

 (87mm) 

2

5

/

8

” (67mm) 

2

5

/

8

” (67mm) 

Mounting 

 Tab 

To 

Cat5e/6 

Cable 

To Protected 

Device 

Ground 

1

1

/

16

” 

(27mm) 

  ENFORCER

 

IP

 

Surge

 

Protector

 

SECO-LARM U.S.A., Inc. 

3

 

 

1x  IP Surge Protector  

4x  Mounting Screws 

1x  12” (305mm) Ground Cable 

4x  Plastic Wall Anchors 

 

 

 

 

 

 

 

Protecting Multiple Devices: 

1.

 

Mount the IP Surge Protector as close as possible to the device to be protected. 

2.

 

Detach the Cat5e/6 cable from the device to be protected and attach to the “Unprotected” port 
of the IP Surge Protector. 

3.

 

Attach an additional short Cat5e/6 cable between the device to be protected and the 
“Protected” port of the IP Surge Protector. This cable should be as short as possible to connect 
the two devices. In addition the protected cables should not cross unprotected cables.  

4.

 

Use supplied ground cable to connect the ground (GND) terminal to earth ground. The system 
should use a single ground point and the protected device should be isolated from ground.  

Protecting a Single Device: 

Installation: 

NOTE

: These instructions assume that 2 IP devices have already been connected together. 

Parts List: 

Shortest 
Possible 

Cat5e/6 cable 

Shortest 
Possible 

Cat5e/6 cable 

Protected 

End 

Protected 

End 

IP Switch 
(Protected) 

IP Surge 

Protector 

Unprotected 

End 

To ground 

Original Cat5e/6 cable 

To ground 

IP Surge 

Protector 

IP Camera 
(Protected) 

Unprotected End 

Shortest 
Possible 

Cat5e/6 cable 

IP Surge 

Protector 

To ground 

IP Switch       

(Not Protected) 

IP Camera 

(Protected) 

Cat5e/6 cable 

Protected End 

1.

 

Mount the two IP Surge Protectors as close as possible to each device to be protected.  

2.

 

Detach the Cat5e/6 cable from each device to be protected (such as an IP switch or IP camera) 
and attach to the “Unprotected” port on its respective IP Surge Protector. 

3.

 

Using additional short Cat5e/6 cables, connect each device to be protected to the “Protected” 
end of its respective IP Surge Protector. These cables should be as short as possible to 
connect each device to its respective surge protector. In addition the protected cables should 
not cross unprotected cables. 

4.

 

Use supplied ground cable to connect each IP Surge Protector’s ground (GND) terminal to 
earth ground. The system should use a single ground point and the protected device should be 
isolated from ground. 
 